ELLARD DV24AF Venetian Blinds Motor Instructions
- June 5, 2024
- ELLARD
Table of Contents
- DV24AF/L , DV24CFQ/L DVQ24AF/L
- Instruction | A-04
- Features
- Fields of Application
- Specifications
- Product Feature Comparison
- Motor Installation
- Caution
- Setting Notice
- Button Instructions
- 1 Pairing
- 2 Upper and Lower Limits Setting
- 3 Add A Preferred Position
- 4 Adjust Limits
- 5 Activate / Deactivate Jog / Tilt Mode
- 6 Pair / Unpair Additional Emitter
- 7 Remove All Emitters
- 8 Deleting All Limits
- 9 Speed Regulation
- Quick Index
- Troubleshooting
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
DV24AF/L , DV24CFQ/L DVQ24AF/L
Instruction | A-04
Features
- Electronic Limit
- Dual Shaft
- Stall Protection
- Limit Fine Adjustment
- Built-in Receiver
- Jog & Tilt
- Program Button
- Reset to Factory Mode
- Memorized Settings
- Preferred Stop Position
- Speed Regulation
- Low Power Consumption
Fields of Application
The motor is suitable for motorization of venetian blinds.
Specifications
Working temperature: -10°C ~ +55°C | Radio Frequency: 433.925MHz |
---|---|
Rated Voltage: DC 12V | Maximum Running Time: 6 minutes |
Following data for reference
Model
| Rated Torque
(N.m)| Rated Speed
(rpm)| Rated Current
(A)
---|---|---|---
DV24AF/L-0.8/45| 0.8| 45|
0.83
DV24CFQ/L-0.5/34
| 0.5| 34| 0.76
DVQ24AF/L-0.8/45| 0.8| 45|
0.83
- For reference only.
Product Feature Comparison
Model
| Motor Schematic| Full Speed Start/ Slow Start Slow Stop| Motor
Length
---|---|---|---
DV24AF/L| | Full
Speed Start|
193mm
DV24CFQ/L
| Slow Start Slow Stop
DVQ24AF/L| | Full
Speed Start|
206mm
*Full speed start refers to the motor running at a uniform speed under any conditions; Slow start slow stop refers to the motor in any circumstances to slow start, then fast running, finally run slowly until stopped.
Motor Installation
Caution
- Do not expose motor to humid or extreme temperature conditions.
- Do not drill into motor.
- Do not cut the antenna and keep it clear from metal objects.
- Do not allow children to play with this device.
- If power cable or connector is damaged, do not use.
- Ensure correct crown and drive adaptor are used.
- Ensure power cable and aerial is clear and protected from moving parts.
- Cable routed through walls shall be properly isolated.
- Motor is to be mounted in horizontal position only.
- Before installation, remove unnecessary cords and disable equipment not needed for powered operation.
- Installation and programming to be performed by a qualified professional, use or modification outside the scope of this instruction may void warranty.
Important Safety Instructions To Be Read Prior To Operation.
Setting Notice
Please read following points of attention carefully before setting.
-
Don’t operate motors when low voltage alarm:
During operation, motor will stop running when the voltage is lower than 8.0V and it will resume again when the voltage is greater than 8.5V. -
Operation:
(1) The valid interval time of the buttons is within 10S, if there is no operation within 10S, the emitter will exit the present setting.
(2) The motor will jog as hint, pls operate after the jog. -
Set the limit position:
(1) After the upper / lower limit setting, and the upper / lower limit position can’t at the same position.
(2) After the limit setting, with power off and memory function.
(3) Limit delete will clear all limit memory.
(4) It will exit limit setting when program there is no operation for 2 minutes. -
If the emitter lost, please setting up again with new emitter.
-
One motor can store maximum 20 channels; after fully stored, if pair new channels, only the last one will be covered circularly
Button Instructions
Functions of P1 button
- Cycle Operation: Press P1 button once and every press the motor will run upward → stop → downward circulary.
- Pairing or Pair Additional Emitter: Press P1 button for 2S, motor jog once, release button, motor is ready for pairing or pair additional emitter.
- Switch Direction: Press and hold P1 button for 6S, the motor will jog twice, release button, the running direction of the motor has been changed.
- Reset to Factory Mode: Press and hold P1 button for 12S, the motor will jog 3 times, release button, the motor has been reset to factory mode.
Essential Settings
Step 1 to 2 must be completed to ensure proper operation.
1 Pairing
Press P1 button for 2S (1 jog ), or power on motor (1 jog), press P2 (1 jog ), P2 again (1 jog), and UP (1 jog), motor is paired with emitter.
*After the success of the code will delete the original limit settings and motor running mode speed settings, restore the factory value.
2 Upper and Lower Limits Setting
1 Initiate limit setting
Press P2 (1 jog ), UP (1 jog ), and P2 (1 jog ), motor is ready for limit settings.
*In the process of motor running upward or downward, press P2, the motor enters the stepping operation state, can precisely set the limit position.
2 Set upper limit
Press UP, operate the motor to desired upper position, press STOP once, motor stops, then press 5 times or press and hold STOP for 3S(1 jog ), upper limit is set.
3 Set lower limit
Press DOWN,operate the motor to desired lower position, press STOP once, motor stops, then press 5 times or press and hold STOP for 3S (1 jog ), lower limit is set.
*Power on the motor again after power off will exit the limit setting mode. Exit the limit setting mode before completing the limit setting. If you have already set the limit before setting, you can only fine-tune the limit.
3 Add A Preferred Position
Check both upper and lower limits are set. Operate the product to desired preferred position. Press P2 (1 jog ), STOP (1 jog ), STOP again (1 jog ), the preferred position is set.
- Repeat same procedure will remove preferred position.
*In the normal running mode, if the motor is not at the preferred position, press STOP button longly, then the motor will run directly from the current position to the preferred position (apply for roller systems); In the jog mode, press STOP button longly, firstly, the motor runs from the current position to the lower limit then to the preferred position (apply for cord-lifting system).
4 Adjust Limits
1 Adjusting the upper limit
Operate product to upper limit position. Press and hold UP and DOWN buttons simultaneously for 5S(1 jog), operate the product to desired new upper limit position, press and hold STOP for 5S (1 jog), the new upper limit is programmed successfully.
2 Adjusting the lower limit
Operate product to lower limit position. Press and hold UP and DOWN buttons simultaneously for 5S(1 jog), operate the product to desired new lower limit position, press and hold STOP for 5S (1 jog), the new lower limit is programmed successfully.
*After fine-tuning the upper or lower limit position,the original preferred position will be automatically replaced; If fine-tuning is not successful, the original upper or lower limit position is still used; Fine-tuning the limits, press UP or DOWN once, the motor will be jog running, if press more than 2 second, the motor will be continuously running.
5 Activate / Deactivate Jog / Tilt Mode
Press P2 (1 jog ), UP (1 jog ), and DOWN (1 jog ), Jog / tilt mode is deactivate.
- Repeat same procedure will activated Jog / tilt mode.
*when in jog mode, press UP or DOWN once, the motor will be jog running, if press more than 2 second, the motor will be continuously running; When the jog mode is off, the up-jogging and down-jogging can also make the motor jog running.
6 Pair / Unpair Additional Emitter
Method one
Press P2 (1 jog ) and P2 (1 jog ) on existing emitter, press P2 on new emitter to add (1 jog), new emitter is paired to the motor.
-
Repeat same procedure will unpair additional emitter.
-
-
Method two
Press P1 button for 2S (1 jog ), release button, press UP and DOWN on new emitter for 2S to add (1 jog ), new emitter is paired to the motor.
*(a) as existing emitter, (b) as new emitter to pair/unpair; All the setting of the motor will be kept after adding the new emitter.
7 Remove All Emitters
Press P2 (1 jog ), STOP (1 jog ), and P2 (1 jog ), all emitters are deleted.
8 Deleting All Limits
Press P2 (1 jog ), DOWN (1 jog ), and P2 (1 jog ), all limits are removed.
*This operation is deleted along with preferred position.
9 Speed Regulation
1 Acceleration setting
Press UP and STOP simultaneously for 2S (2 jogs), The motor speed is raised to the second gear. If the motor is jogs 3 times, the motor speed is raised to the third gear.
2 Deceleration setting
Press DOWN and STOP simultaneously for 2S (1 jog), the motor speed is reduced to first gear. If the motor is jog twice, the motor speed is reduced to second gear.
*If the motor no response, it has already been the Max. or Min speed.
Quick Index
|
Settings
|
Steps
---|---|---
1
| Pairing| P1 → P2 → P2 → Up
2
| Initiate Limit Setting / Confirm Limits| Initiate limit setting P2 → Up
→ P2
Set upper limit Up → Stop → Stop (hold down 3s or press 5 times)
Set lower limit Down → Stop → Stop (hold down 3s or press 5 times)
3
| Add / Remove Preferred Position| P2 → Stop → Stop
4
| Adjust Limits| Adjusting the upper limit Up → Up + Down (hold down 5s) →
Up or Down →Stop (hold down 5s)
Adjusting the lower limit Down → Up + Down (hold down 5s) → Up or Down
→Stop (hold down 5s)
5
| Activate / Deactivate Jog or tilt mode| P2 → Up → Down
6
| Pair / Unpair Addition Emitter| P2(a) → P2 (a) → P2(b)
P1 → Up(b) + Down(b)
7
| Remove All Emitters| P2 → Stop → P2
8
| Delete All Limits| P2 → Down → P2
9
| Speed Regulation| Acceleration setting Up + Stop (hold down 2s)
Deceleration setting Down + Stop (hold down 2s)
Troubleshooting
Issues
| Possible causes|
Solution
---|---|---
The motor has no response| Power Failure Or Incorrect Connection| Double check
power and cable connections, follow wiring instructions.
emitter battery is low capacity| Replace battery
Radio interference / shielding| Check antenna on motor is intact and exposed.
Check for possible source of radio interference.
Out of radio control range| Try control within closer range
The emitter can’t control single motor| Multiple motors are paired to the same
channel.| Pair single motor with emitter correctly
Try to use multi-channel emitters to control multi-motor projects, ensure each
channel to control one single motor
The motor doesn’t run or starts too slowly or make loud noise| Connections are
incorrect.| Check connections
Incorrect installation or overload| Check installation or overload
The motor stops during the up and down running| The motor has reached the
lower limit| Adjust the new lower limit
The running time more than 6min| Let the motor cool for about 20 min
SAFETY NOTE
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
- Children shall not play with the appliance.
- Cleaning and user maintenance shall not be made by children without supervision.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- WARNING: the drive shall be disconnected from its power source during cleaning, maintenance and when replacing parts.
- The instructions shall state that the A-weighted emission sound pressure level of the drive is equal to or less than 70 dB(A), e.g. by writing LpA ≤ 70 dB(A).
- The mass and the dimension of the driven part shall be compatible with the rated torque and rated operating time.
- The type of driven part the drive is intended for.
- WARNING: Important safety instructions. It is important for the safety of persons to follow these instructions. Save these instructions.
- Do not allow children to play with fixed controls. Keep remote controls away from children.
- Frequently examine the installation for imbalance and signs of wear or damage to cables and springs. Do not use if repair or adjustment is necessary.
- Watch the moving shutter and keep people away until the shutter is completely closed.
- WARNING: Important safety instructions. Follow all instructions, since incorrect installation can lead to severe injury.
- Before installing the drive, remove any unnecessary cords and disable any equipment not needed for powered operation.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>