TELTONIKA BAT120 UPS User Guide

June 5, 2024
teltonika

Networks
BAT120
Quick Start Guide v1.1

Wike Knowledge base

https://wiki.teltonika-networks.com/

FRONT VIEW

| TELTONIKA BAT120 UPS - FRONT
---|---

BACK VIEW

| TELTONIKA BAT120 UPS - BACK VIEW

IN/OUT POWER SOCKET PINOUT

TELTONIKA BAT120 UPS - PINOUT

LED INFORMATION

IN PWR LED lights up – PSU connected to IN PWR socket.
OUT PWR LED lights up – OUT PWR socket connected to the device.
POWER LEDs light up – Shows BAT120 state of charge. Every LED is 25% of SOC.
All LEDs blinking every 500 ms – BAT120 overheated.
OUT PWR LED blinking every 500 ms – OUT PWR shorted.
POWER LEDs lighting up in sequence – BAT120 is charging.
POWER LEDs blink every 5 s – BAT120 is in sleep mode.

HARDWARE INSTALLATION

  1. Connect Teltonika Networks device power input (PWR) with BAT120 power output (OUT PWR) using provided 4-pin to 4-pin cable.
  2. Connect PSU 4-pin plug to the BAT120 power input (IN PWR) to power up BAT120 and the end device.

BAT120 CHARGING

  1. Set On/Off slider located on BAT120 front panel to On state.
  2. Connect provided PSU to IN PWR socket.
  3. As BAT120 starts charging, it will also power the Teltonika Networks device connected to the OUT PWR socket.

TECHNICAL INFORMATION

Technical specifications

Input voltage range| 9 – 30 VDC
Output voltage In passthrough mode| 9 – 30 VDC
Output voltage In battery mode| 12 VDC
Max output power/current In battery mode| 22 W/1.8 A
Battery capacity| 2300 mAh
Working temperature| 0 °C to 45 °C
**Bundled accessories specifications***
Power adapter| input 0.45 A0100-240 VAC, Output 12 VDC, 2 A, 4 pin plug
Power cable| 4-pin to 4-pin power cable 4 x 0.2 mm2 (24 AWG), 1000 mm

WARNING

This device is equipped with lithium-ion cells. Do not open the casing to avoid cell damage or other hazards.
It is strictly forbidden to dismantle, squeeze, pierce, insert any foreign object and short circuit BAT120, or expose it to liquids, fire, or environments where the temperature is above 60ºC.

SAFETY INFORMATION

BAT120 router must be used in compliance with any and all applicable national and international laws and with any special restrictions regulating the utilization of the communication module in prescribed applications and environments.
Hereby, TELTONIKA NETWORKS declares that this BAT120 is in compliance with the essential requirements and other relevant provisions of Directive 2014/30/EU.
The full text of the EU declaration of conformity is available at the following Internet address: https://wiki.teltonika- networks.com/view/BAT120_CE
Instruction Manual: Connect the power adapter to turn on the device. More information on https://wiki.teltonika-networks.com/

This sign means that all used electronic and electric equipment should not be mixed with general household waste.
This sign means that the product meets the requirements of the applicable EU directives.
www.teltonika-networks.com
2022 Teltonika Networks