Important safety instructions

General conditions of installation

  • Before handling or connecting the equipment, please read this manual.
  • In order to reduce the risk of fire or electric shock, do not expose the equipment to rain or moisture.
  • Do not take the cover off the equipment without disconnecting it from the mains.
  • Do not obstruct the equipment’s ventilation system.
  • Please allow air circulation around the equipment
  • The equipment must not come into contact with water or even be splashed by liquids.
  • Do not place containers with water on or near the equipment if it is not adequately protected.
  • Do not place the equipment near sources of heat or in excessively moisture conditions.
  • Do not place the equipment where it may be affected by strong vibrations or shocks.
  • This symbol indicates that the equipment complies with the requirements of the CE mark.

Description of Inputs / Outputs / Connections

The module features (Fig. 1) the following:

  1. Powering bus connector. Status LED
  2. Control bus connector
  3. RJ45 Ethernet connector
  4. Programmer / PC connector
  5. USB Host connector
  6. SIM. GSM/GPRS operator card
  7. GSM Antenna(Quadband)

Introduction

  • The CDC H/E Manager implements an element with the ability to convert Televés headends in a communications center, either through its internal modem GSM/GPRS (Ref 555901) or via the Ethernet interface for IP communications (Ref 5559 and Ref 555 901).
  • It allows control and monitoring, both locally and remotely, of T.0X headends of Televes, serving as a base platform for the implementation of current and possible future services.

Technical specifications

CPU Processor ARM920T™ ARM®
Memories Type 8 MB Flash

64 MB de SDRAM
128M x 8 Bit NAND Flash Memory
Interfaces
Connectors| T.OX powering| 24V| R145 connector| 10/100 Base-T Ethernet
Interface| RS-482| RJ45 connector| Debugging / Programmer LCD
Interface| USB 2.0 Full Speed Host (12 Mbps)| GSM Antenna connector| F connector
SIM Interface| SIM cards reader| |
GSM/GPRS
Radio Interface| Transmission power| GSM-850 / 900
Power peak 2W RF (+33dBm) over 50 Ohm| VSWR (Voltage Standing
Wave Ratio)| max. absolute| s 5 :1
DCS-1800 / PCS-1900
Power peak 1W RF (+30dBm) over 50 Ohm| recommended| s 2:1
Reference Sensitivity| GSM-850 / 900 -107 dBm| Input power (peak)| > 2 W
DCS-1800 / PCS-1900 -107 dBm| Antenna impedance| 50 ohm
Antenna gain| 1.5dBi Gain < 3dBi
(reference: X/2 dipole )| Bandwidth| 70 MHz for GSM 850, 80 MHz for GSM 900, 170 MHz for DCS, 140 MHz for PCS band
GPRS| GPRS CLASS 10| Max. uplink transmission rate 42,8 kbps
Encoding schemes: CS1, C52, CS3 and CS4| Packet Broadcast Control Channel
Max. downlink transmission rate: 85,6 kbps|
Peripherals| | Real-Time Clock/ Alarm Digital thermometer
Operating system| Linux Kernel 2.6.16
General| Powering| 24 V| Operating temperature -5 …. +45°C
Consumption| 300 mA| Protection index IP20

These technical specifications are defined for an ambient temperature of 45 ° C (113 º F). For higher temperatures, forced ventilation must be used.

Control / Monitorization
Links’ Server
The CDC H/E Manager was designed to implement, through IP GSM-GPRS, remote communication between any T.0X headend and the Client Control’s Software. This can be done directly or through a Link Server that allows a plug-and-play installation, thus not requiring any kind of IP network configuration.

Ref. 555901 enables IP communication either through Ethernet or via the GSM / GPRS. Direct connections are also possible by either of the two networks.
The ref. 555901 can establish data communication with the Link Server via Internet, on the GSM GPRS network.
The GSM / GPRS provides fixed IP.
Links Server allows centralized management and monitoring of multiple headends.

Televes 5559 T.OX Series CDC HE Manager Headend Controller - fig
6

Both the Web server and CDC Software Server are also accessible locally to the refs. 5559 and 555901.
The connection can be implemented on a LAN, or even directly over the Internet, if you publish the output ports of CDC H/E MANAGER services.
The CDC Headend Manager allows local configuration through the LCD programmer Ref. 7234.

Televes 5559 T.OX Series CDC HE Manager Headend Controller - fig
7

Web Server
The ref. 555901 has a Web server, which enables its settings. It allows visual monitoring of the elements connected to the T.0X BUS.

Televes 5559 T.OX Series CDC HE Manager Headend Controller - fig
8

Displays a list of devices that are connected to T0X BUS, and their status. Green means that the T0X module is correct. Orange indicates that, at times, the module has had incorrect states. Red indicates the module is in a bad state of communication with the BUS.

Using the Web service you can perform an updating of the T.0X CDC remotely.
The figure illustrates the steps for its realization.

DECLARATION OF CONFORMITY N° 130612101125
Manufacturer.
Televes S.A. Rua Den41ica de Comm, 17 -15706 – Santiago de Compostela – Spain

Declare under our own responsibility the conformity of the product.
Reference
5559 Description
Modem CDC-1P TOX Trademark.
Televes With the requirements of

  • Low Voltage Directive 2006 /95 / EC
  • EMC Directive 2004 / 108 / EC Following standards

EN 60950-1:2006 + A1:2010 + A11:2009 + Al2:2011, EN 55022:2010, EN 55024:2010

DECLARATION OF CONFORMITY N° 130612102153
Manufacturer.
Televes S.A. Rua Benetica de Como, 17 – 15706 – Santiago de Compostela – Spain Declare under our own responsibility the conformity of the product.
Reference
555901, 555903 Description
Modem GSM TOX Trademark
Televes With the requirements of,

  • R&TTE Directive 1999/5/EC Following standards,

ETSI EN 301 489-1:2011, ETSI EN 301 489-7:2005, ETSI EN 301 511:2003, EN 55022:2010, EN 55024:2010,EN 60950-1:2006 + A1:2010 + 11:2009 + 12:2011

Documents / Resources

| Televes 5559 T.OX Series CDC H/E Manager Headend Controller [pdf] User Guide
5559, T.OX Series CDC H E Manager Headend Controller, 5559 T.OX Series CDC H E Manager Headend Controller, 555901
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals