Televes 534483 CATV Indoor Amplifiers Instruction Manual
- June 3, 2024
- Televes
Table of Contents
Televes 534483 CATV Indoor Amplifiers
OVERVIEW
- Input connector
- Test IN -20dB
- Test OUT -20dB
- Output connector
Important Safety Instructions
General installation conditions
- Before handling or connecting this equipment, please read carefully all warnings and instructions in this manual.
- In order to reduce the risk of fire or electric shock, do not expose the equipment to rain or in excessively moisture conditions.
- Do not open the equipment without disconnecting it from the mains.
- Do not obstruct the equipment’s ventilation system.
- Please, allow air circulation around the equipment.
- The equipment must not come into contact with water or even be splashed by liquids. Do not place containers with water on or near the equipment if it is not adequately protected.
- Do not place the equipment near heat sources, like radiators, stoves, heater or other electronic equipment.
- Do not place the equipment where it may be affected by strong vibrations or knocks.
How to use the equipment safely
- If any liquid or object falls inside the equipment, please contact a specialized technician.
- Do not connect the equipment to the mains until all the other connections have been made.
- The mains socket that is going to be used to connect the equipment should be located nearby and should be easily accessible.
- Make sure that all power cords, plugs and cables are not pinched or bent sharply to prevent any possibility of damage, electrical shock or fire.
- Unplug the unit power cord by gripping the plug only.
Input & Output description
General description
Range of amplifiers designed for multimedia distribution in small/medium size
buildings.
These amplifiers feature forward and passive/active return path with their
correponding range of attenuators and equalizers that provide the optimum
adjustment to deliver the right output level in accordance with the
installation needs. Amplifier’s setting up is carried out by means of
removable
jumpers that allow to select fixed stepped values. The use of jumpers allows
an easy reading of each setting.
The active return path is fully configurable by means of plug-in jumpers.
Attenuation ranges from 0 to 18 dB in fixed steps of 2 dB. The equalizer is an
interstage type ranging from 0 to 6 dB in fixed steps of 3 dB.
The forward path features both configurable input attenuator and input equalizer by means of jumpers in steps of 2 dB. Furthermore, it has selectable interstage attenuation and equalization by means of two double jumpers.
The forward gain is selectable by double jumper, allowing to decrease 0 or
5dB.
Furthermore, it has selectable interstage equalization (tilt), with double
jumper allowing 0 or 6 dB
settings.
The amplifier is housed within a die-cast enclosure that contributes to reduce
the temperature of its components due to its excellent heat disipation.
An ON/OFF LED indicates when the amplifier is connected to mains. On the other
hand, a LED inside indicates if the amplifier is being powered.
Once opened (untightening the screw located on its front), an intuitive
diagram of blocks explains how the amplifier works to achieve the desired
output level.
Open the amplifier by untightening the screw located on its front lid.
The amplifier block diagram is inside the unit. To set
attenuation/equalization, plug-in the jumper into the required value for the
installation.
The forward path features separate interstage equalization and attenuation.
Two double jumpers can be set in two positions, as indicated in the diagram.
Jumper positioned “=” do not attenuates the signal. Jumper positioned ” =”
attenuates the signal by 5 dB.
In the same way you can proceed with the double jumper for the equalization.
Once all settings have been made, close de enclosure and thighten its frontal
screw.
Block diagram
- Forward path input equalizer 0-18 dB, 2 dB steps.
- Forward path input attenuator 0-18 dB, 2 dB steps
- Equalizer 0 or 6 dB.
- Forward path interstage attenuator 0 or 5 dB
- Forward path output
- Return path input
- Return path input attenuator 0-18 dB, 2 dB steps
- Return path input equalizer 0/3/6 dB
- Forward path input
- Return path output
- Return path configuration active
Technical specifications
Especificaciones técnicas| Technical specifications|
534482| 534483
---|---|---|---
Canal Directo| Forward path| |
Rango de frecuencia| Frequency range| MHz| 54 … 1220
Ganancia| Gain| | 351
Desviación valor nominal| Nominal value deviation| | ± 1
Planicidad| Linearity| | ± 1.5
Atenuador de entrada| Input attenuator (2dB steps)| | 0 … 18
(pasos de 2 dB)| |
Atenuador entre etapas| Interstage attenuator| dB| 0/51
Ecualizador Entrada| Input equalizer (2dB steps)| | 0 … 18
(pasos de 2 dB)| |
Ecualizador entre etapas| Interstage equalizer| | 0/6
Figura de ruido| Noise figure| | < 7.5
Tensión CSO > 60dB*
de salida CTB > 60dB*
|
Output level
| CSO (42 CHs) > 60dB|
dBmV
| 45
CTB (42 CHs) > 60dB| 45
Pérdidas de retorno| Return losses|
dB
| >12
Toma de prueba| Test socket| -20
Canal de retorno| Return path| | |
Rango de frecuencia Frequency range| MHz| 5 … 422
Ganancia activo/ pasivo| Gain active/passive| | 28/-1
Desviación valor nominal| Nominal value deviation| | ± 1
Planicidad| Linearity|
dB
| ± 1
Atenuador de entrada| Input attenuator (2dB steps)| 0 … 18
(pasos de 2 dB)| |
Ecualizador entre etapas| Interstage equalizer| | 0/3/62
Figura de ruido| Noise figure| | < 6
Tensión 64QAM 4TP (En de salida cumplimiento de
la norma KBW)
| Output level| 64QAM 4TP ( In
compliance with KBW standard)
|
dBmV
|
55 (BER: 1.0 e-8)
Pérdidas de retorno| Return losses|
dB
| >12
Toma de prueba| Test socket| -20
General| General| | |
Consumo Power consumption| W| 6,6
Consumo máx. total
Tensión de red
| Max. total consumption
Mains voltage
| mA
V~
| 107
110 – 230
Hz| 50-60
Tipo de clavija| Plug type| | |
Temperatura de trabajo| Operating temperature| ºF/ºC| +14 . . . +113 /-10 … +
45
Protección descargas electrostáticas (EN61000-4-2)| Electrostatic discharges
protection (EN61000-4-2)|
kV
|
8
Clase de protección| Protection class| class| II isolation
Índice de protección| Protection index| IP| 20
Conectores RF| Connectors RF| type| F-female
Dimensiones| Dimensions (W x H x D)| in /mm| 7.2 x 3.1 x 1.3 / 185 x 80 x 35
Peso| Weight| lb /g| 0.88 / 400
- Gain configurable by means Interstage attenuator 0/5dB.
- Active/passive configurable by means plug in jumpers
Typical applications
Description of the electrical safety symbols
This symbol indicates that the equipment complies with the safety requirements for class II equipment.
This symbol indicates that the equipment complies with the requirements of the CE mark.
Recycling information
The disposal of this product after its useful life must be made as an
electronic scrap in compliance with the current disposal regulations of your
district/country.
Class B equipment.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Televes USA LLC. Norfolk Tech Center 16596 E. 2nd Avenue Aurora, CO 80011 USA
Telephone: +1 (720) 379 3748
televes.usa@televes.com