Televes 593100 Series CATV Meter Analyzer with Remote Control User Guide
- October 27, 2023
- Televes
Table of Contents
- Televes 593100 Series CATV Meter Analyzer with Remote Control
- Overview
- Key Features
- General Specification
- Technical Specifications
- Description of equipment components
- Keyboard
- Power supply
- Product Operation
- Channel Info
- System Scan
- Tilt
- Spectrum
- Constellation
- Voltmeter & Hum
- Learning plan
- Speed Test
- IPTV (H30D+Adv.)
- Echoes (H30D+Adv.)
- Web Application
- Maintenance
- Warranty
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Televes 593100 Series CATV Meter Analyzer with Remote Control
Overview
Introducing the H30+.
New from Televes, a go-to meter designed with the needs of a Cable TV operator in mind. The H30+ is a lightweight, rugged unit, packed with all the features needed to install and troubleshoot a television system using QAM digital modulation as well as analog signals. This handy little unit is even inexpensive enough to leave in your headend and use its unique in its class remote measurement and control capabilities to provide long-term monitoring or to troubleshoot those hard-to-find, intermittent problems.
Available for the first time in such a portable and affordable package, its real-time digital processing engine gives the installers the lab-precision measurements needed in today’s fulfillment environment.
Key Features
- User friendly, handheld QAM meter.
- Remote measurements and control in an affordable package.
- Complete portfolio of Analog/Digital measurements with easy-to-read pass/fail indicators.
- Quick and easy to use interface with features such as Channel measurements, System Scans, Tilt Function, Constellation Diagram, Spectrum Analyzer, Voltmeter, Hum, Service Identification, Datalogger, and more.
- Rugged, light weight, fully automatic, fast, and accurate.
- Automatic through-the-cloud software updates.
- 100% automatic ITU-T J.83 Annex A/B parameter detection and measurement with no setup needed.
- Up to 1794MHz spectrum range with selectable span.
- PASS/FAIL Indicators: Icons indicate if a measurement is good, bad, or in the warning zone for quick and easy status checks. Reduce installer entry errors and improve decision making.
- Control your H30+ remotely and make measurements from any internet connected device. Ideal for extended signal tests over time in headends and broadband distribution networks. Leave your H30+ connected to your headend or anywhere in your plant and control the unit and measure signals and quality parameters remotely. Once finished, export the results to your computer using the included Remote Application software.
General Specification
Display | 2.8” TFT 400 x 240 full colour |
---|---|
Weight | H30+ : 529g (1.16lb) |
H30D+ & H30D+Adv: 633g (1.39lb)
Dimensions| 6.9 x 3.9 x 2 in / 175 x 100 x 52 mm (H x W x D)
AC Adaptor| Input: 100-240V~ 50-60Hz
Output: 12VDC, 2A
Battery| Li- Ion smart battery (7.2VDC, 2550mAh)
Operating Time| Up to 4 hours
Operating Temperature| -5ºC to 45ºC (23ºF to 104ºF)
Storage Temperature| -20ºC to 70ºC (-4ºF to 158ºF)
Humidity| 5% to 95% non-condensing
Ruggedness| Survives 1 m (3 ft) drop to concrete on all sides
Communication Interfaces| RJ45 10/100/1000-T Ethernet interface for
Remote Control, Measurements, Datalog Retrieval and Automatic Software Updates
Storage| 1.5 GB (internal) for measurements
Power up time| < 10 seconds
Technical Specifications
References
H30+| 593901
H30D+| 593902
H30D+ Advance| 593905
Frequency
Range| 593901: 5 MHz to 1002 MHz
593902: 5 MHz to 1218 MHz
593905: 5 MHz to 1794 MHz
Resolution| 50 kHz
Tuning| Frequency or channel
Input
Impedance| 75Ω F-type connector
Spectrum Analyzer
Span| 2.5, 6.25, 12.5, 25, 62.5, 125, 250, 500 MHz
and Full
Scale| 5 and 10 dB/div
Auto and manual reference level| **
Reverse Path Ingress Scan
Range| Selectable 5 to 42MHz, 5 to 65MHz, 5 to 85MHz and 5 to 204MHz
Mode| Peak, Average, Min, and Real-time
Digital Channel Power Measurements
Power| -15 to +50 dBmV (-35 to +60dBmV opt.593235)
Accuracy| ±2 dB
Resolution| 0.1 dB
Digital Measurements DVB-T (H30D+Adv or opt. 593231)
Freq. Range| 42 – 1002MHz
Modulations| COFDM (QPSK, 16QAM, 64QAM)
MER| Up to 35dB
C/N| Up to 40dB
CBER| 9.9E-2 – 1.0E-6
VBER| 1.0E-3 – 1.0E-8
Echoes|
Constellation with Zoom Capability| **
Digital Measurements DVB-T2 (H30D+Adv or opt. 593231 + 593232)
Freq. Range| 42 – 1002MHz
Modulations| COFDM (QPSK, 16QAM, 64QAM and 256QAM)
MER| Up to 35dB
C/N| Up to 40dB
LDPCBER| 9.9E-2 – 1.0E-6 (Pre LDPCBER)
BCHBER| 1.0E-3 – 1.0E-8 (Pre BCHBER or Post LDPCBER)
Link Margin| Up to 30dB
Echoes|
Constellation with Zoom Capability| **
Digital Measurements DVB-C
Freq. Range| 42 – 1002MHz
Demodulation| ITU-T J.83 Annex A/B standard
Support| 16, 32, 64, 128 and 256 QAM, QPSK
Symbol Rate| 2 to 6.9 MS/sec
Q.A.L. Technology (QAM Auto Lock)| Automatic detection of signal
characteristics and modulation parameters
C/N| Up to 45 dB
---|---
MER| Up to 45 dB
Pre-BER and Post-BER (Annex B)| 1.0E-3 to 1.0E-8
BER (Annex A)| 1.0E-3 to 1.0E-8
Constellation with Zoom Capability| **
Analog Measurements
Freq. Range| 42 MHz to 1002 MHz
Level measurement| -15 to +50 dBmV (-35 to +60dBmV opt.593235)
V/A| up to 30 dB
C/N| up to 54 dB
Accuracy| ±2 dB
Resolution| 0.1 dB
Channel Plans
Factory channel plans| FCC STD, FCC EXT, FCC OFFAIR, CCIR, CCIR+LTE
Custom channel plans| **
(learning plan)
System Scan
Channels| User selectable zoom up to all channels (analog or digital)
Measurements| Level bar representation and C/N BER/MER of the selected
channel
Tilt
Channels| Up to 16 channels (analog and/or digital)
Selectable markers| **
Pass/Fail Indicators
Factory profiles| Headend, Fiber Nod, Trunk, Bridge, Line Ext, Tap, End
Line, Ground, Modem/STB, Off Air
Custom profiles| up to 20 profiles
Voltmeter
Range| ±5VDC to ±150VDC, ±5VAC to ±100VAC
Accuracy| ±(0.5V +1%)
Speed Test
DCHP Status| **
Connection Status| **
Ping| **
Lost packets| **
DS/US speeds
| 593901: 20Mbps
593902: 500Mbps
593905: 1000Mbps
Service Info
Channel parameters| NIT, PAT, TSID, CBRT, number of services
Service parameters| SID, VID, AID, bitrate, encoding type
Video visualization| MPEG-2 / MPEG-4
HEVC visualization| Up to 1080p (H30D+Adv or opt. 593252)
Cable Modem (H30D+ / H30D+ Adv)
Modes| 3.1 / 3.0 / BPI+
Dowstream| Up to 32 QAM channels and 2 OFDM channels of 192MHz
UpStream| Up to 8 QAM channels and 2 OFDM-A channels
Connect Status| DS and US frequency, DHCP, TOD, config. file name,
security level, registration
---|---
Diplexer| Auto (config. file) or user selectable (5-85MHz / 108-1002MHz)
(5-204MHz / 258-1218MHz)
Measurements| Bar diagram of DS and US channels. Power, MER, PreBER and
PostBER of selected channel
Throughput Test| IP modem, DS and US maximun speed, ping current and
average delay, lost packets, transfer speed
Modem Emulation| Connection status of the modem, instantaneous speed and
size data sent through the modem
D3.1 Advanced Measurements
| PLC: Frequency, level, MER, CWE Level: average, max, min
MER: average, std, pctl NCP CWE
Profile A: Corrected / Uncorrected CWEMER:
average, std, pctl
Upstream Equalizers| Bar diagram of US channels equalizer,
level, time and distance of selected channel
Throughput Test
| DHCP Status, Connection Status, Ping Delay, Lost Packets,
Upstream and Downstream Speed, Modem IP, maximum DS and US Speed,
current and average PING delay, lost packets, transfer speed (via FTP).
LT Monitoring
Historical measurements in the selected channel|
Time interval between two consecutive measure shots|
User defined
Connectivity
Bluetooth|
Wifi|
Wi – Fi Scan (H30D+Adv or Option 593250)
Automatic Wi-Fi networks scan|
Data shown| networks name, MAC, channels,
access point power, protection access type
Views| list and map
IPTV Analyzer (H30D+Adv or Option 593251)
Measurements
| packets per second,
min. and max. packet arrival time,
IP payload bitrate, UDP payload bitrate, media loss rate, lost IP frames
Service info|
- Specifications are subject to change without notice.
Description of equipment components
Connectors and controls
- External power connector (12VDC).
- LCD display.
- Keyboard and LED indicators
- Ethernet connector.
- USB connector.
- RF F-connector.
- DOCSIS connector.
Keyboard
- Device On/Off button: To turn the equipment off, press and hold for approximately 3 seconds.
- Back button: Return to the previous menu or close a parameter entry window.
- Home button: Return to the main menu.
- Navigation buttons through options.: Used to scroll
- OK Button: To confirm the selection.
- Setup button: Parameter window for the current function.
- LED Load: Indicates if the equipment is powering an external load.
- LED Charging Battery: Indicates if the battery is charging.
- LED Power ON: Illuminated when the equipment is on.
Power supply
A DC adapter is provided to power and charge the meter. Plug the adapter into a properly grounded electrical supply and the power connector on the side of the unit.
When external power is supplied, the battery management system automatically controls the charging process. A battery icon indicates the charge status of the battery. When the battery is fully charged, the battery icon is completely filled. As the battery discharges, the amount the icon is filled decreases in steps. The icon shows 5 states representing the approximate battery charge:
- Battery charge less than 5%.
- Battery charge between 5% and 25%.
- Battery charge between 25% and 50%.
- Battery charge between 50% and 75%.
- Battery charge greater than 75%.
From a fully discharged state, a full charge takes approximately 8 hours and a 3 hour charge will provide approximately a 75% charge. The charge management system will detect various conditions preventing charging, such as a battery that is over a safe temperature.
Battery Recommendations
To maximize battery life:
- Avoid fully discharging the battery.
- The battery should always be charged with the battery pack attached to the device and using the supplied DC adapter or applying a constant voltage within the specified range (12-15VDC).
- For long-term storage, keep the unit at room temperature, or about 25º C. Start with a charged battery and re-charge the battery every 2 to 3 months.
Product Operation
Docsis (H30D+ / H30D+Adv)
In this menu are grouped all functions related to the Docsis network.
Connection Status
This function shows all the steps the H30D+/H30D+Adv is taking to connect to a DOCSIS network. Each time a step is successfully completed, it is indicated with a checkmark. The steps are shown in order. The first thing that the modem has to do is read the status of the connection. Then, the modem has to range and lock on to the downstream channel. Once the modem is locked, it is shown the frequency of the channel used for receiving data from the CMTS (Cable Modem Termination System). The modem will then attempt the same with the upstream channel. Then, the DHCP server must assign the IP network parameters to the modem. The next step is to synchronize the time with the TOD (Time Of Day) server. In both cases, the IP addresses of the servers will be shown in the window. The modem then gets and displays the name of the configuration file given by the CMTS. Last, is the modem registration status, the level of security (None or BPI+), the DOCSIS version, and the channel bonding configuration.
Main window
Below is a capture of a Connection window with a brief explanation of its
features.
Docsis3.1 Advanced
This function shows all the measurements of the OFDM Docsis channel. In addition to the level and MER measurements, all the PLC (physical link channel) and NCP (next codeword pointer) measurements are also shown which are very important for the system to work properly. For the Level measure, the average, maximum and minimum values of all the frequencies are shown. For the MER measure, the average, maximum and minimum values of all the frequencies are shown. For the PLC, the average, maximum and minimum values of all the frequencies are shown., the MER and the uncorrectable codeword errors. This last measure is also shown for NCP.
Main window
Below is a capture of a Docsis3.1 Advanced window with a brief explanation of
its features.
Measurements
This function shows the status of all the upstream and downstream channels at a glance. The internal modem of the H30D+/H30D+Adv supports two 192 MHz OFDM downstream channels, thirty two single-carrier QAM downstream channels, two 96 MHz OFDM-A upstream channels and eight single-carrier QAM upstream channels. This function graphically shows the status of all of these channels in a way that clearly shows which channels comply with the used-defined thresholds by its green, yellow, or red colour. A single channel can then be chosen for further analysis. The detailed measurements of the selected channel as well as the modulation data
Throughput test
This function measures the upstream and downstream rates of the DOCSIS
network.
The rate measurements are performed using an FTP server that must be
configured by the user (URL, file, get/put, user, password). See section
1.56Setup.
This feature shows the IP modem within the DOCSIS network and the maximum
speed negotiated (DS/US). When you start the speed test, the speed value is
updated at the end of the test.
Main window
Below is a capture of a Throughput Test window with a brief explanation of its
features.
Modem Emulation
This function sets the H30D+/H30D+Adv to be used as a DOCSIS modem. It may be
used to give another device a connection to the DOCSIS network via the
H30D+/D+Adv’s Ethernet port.
Main window
Below is a capture of a Modem Emulation window with a brief explanation of its
features.
Setup
The features in this menu allow you to set the required parameters to analyze a DOCSIS network. You can access to Setup menu by pressing a button.
- Tuning mode: Auto, Manual.
- If Auto is selected, the H30D+/D+Adv tries to find a DOCSIS channel following this searching sequence:
- PLC (with steps of 1MHz)
- QAM Annex B in FCC STD channel plan
- QAM Annex B in FCC HRC channel plan
- QAM Annex A in CCIR channel plan
- If you select Manual, you must select one channel from the Channel list.
- Plan: FCC STD, FCC RETURN, FCC IRC, FCC HRC, FCC OFFAIR, CCIR, Custom plans.
- Channel: Allows you to select the channel when Manual is selected in the Tuning mode. FTP Test: These parameters allows to set the ftp to do the Throughput test.
- FTP Server: Enter the ftp address using navigation buttons
- FTP Path: Enter the file path using navigation
- buttons. Method: GET, PUT. GET selects the downstream channel and PUT select the upstream for the FTP Test in the Troughput test feature.
- User: Enter the user for the FTP server.
- Pass: Enter the appropriate password for the FTP server user.
- Ping Test: These parameters allows to set the IP to do the Throughput test
- IP: Enter the IP address using navigation buttons Count: Enter the number of PINGs to do using navigation buttons
Channel Info
Analog and digital channels are very different in terms of signal content and
power distribution and thus require the advanced SLM techniques provided in
the Televes H30+/D+/D+Adv. In analog mode, video and audio levels, V/A and
Carrier to Noise (C/N) are measured. In digital mode it´s Power, C/N, Pre-BER
and Post-BER.
Main window
Below is a capture of a Channel Info window with a brief explanation of its
features. Setup
Press to change the Channel Info options.
- Ter. Plan: Selected Terrestrial plan.
- Tuning: Channel, Frequency
- A/D: Auto, Analog, Digital
- Save datalog: Saves the current measurements. You can see the catalogs using the remote control application.
System Scan
This function scans the selected channel plan and detects every existing
analog and digital channel in real-time to determine the overall frequency
response of the system.
The scan measurement leverages the location-based thresholds to clearly show
whether or not signal levels comply with the cable system’s specifications
with their green, yellow and red bars. This gives an easy-to-understand real-
time view of the system, including the BER and MER values of the selected
channel.
Main window
Below is a capture of a System Scan window with a brief explanation of its
features:
Setup
Press to change the System Scan options.
- Ter. Plan: Selected Terrestrial plan.
- Digital tuning: If it is ON, allows to see C/N and MER measurements when a digital channel is selected and the user presses Ok button.
- Ref. Level: Select the reference level of the bar graph
- Span: Select the number of channels shown in the bar graph
- Save datalog: Saves the current scan measurements. You can see the catalogs using the remote control application
Tilt
Any number of analog, digital or DOCSIS channels can be measured using the
tilt measurement, and you can even select which carriers are your reference
points to determine the tilt between any of the channels included in the
measurement.
The Tilt measurement leverages the location-based thresholds to clearly show
whether or not signal levels comply with the cable system’s specifications
with their green, yellow and red bars.
Main window
Below is a capture of a Tilt window with a brief explanation of its features:
Setup
Press to change the Tilt options.
- Ref. Level: Select the reference level of the bar graph.
- Ter. Plan: Selected Terrestrial plan.
- Channels: Select the channels to show in the bar graph
- Quality profiles: Trunk, Tap, End Line, Ground.
Select thresholds according to the testing location.
- Save datalog: Saves the current scan measurements. You can see the data logs using the remote control application.
Spectrum
Real-time processing speeds ensure the capture of any fast, intermittent plant impairments. Due to the accuracy and level of detail provided by this spectrum analyzer, the H30+/D+/D+Adv is the ideal tool for identifying and locating noise, interference, ingress, and other waveforms that may be affecting cable service
quality.
Main window
Below is a capture of a Spectrum window with a brief explanation of its features:
Setup
Press to change Spectrum options.
-
Ter. Plan: Selects the channel plan
-
Aim antenna: Emits a modular audible signal with frequency directly proportional to signal level in the spectrum trace relative to a reference level.
It is recommended to set the reference level manually, as well as to select the span to include a frequency range wide enough. The audible signal becomes continuous when the signal leaves close to the reference level. Then it is necessary to increase the reference level to get a more accurate adjustment. This is a useful feature to point antennas without having to look at the display. -
Span: 2.5MHz, 6.25MHz, 12.5MHz, 25MHz, 62.5MHz, 125MHz, 250MHz, 500MHz, Full.
-
Set the span of the spectrum. To easily change the span, use the OK Button to decrease the span and the Back Button to increase the span.
-
Ref. Level: Select the reference level of the spectrum graph
-
Tuning: Channel, Frequency
-
A/D: Auto, Analog, Digital.
-
dB/div: 5 dB/div, 10 dB/div
-
C/N: ON, OFF. Shows/Hides the C/N measure.
-
Hold mode: ON, OFF. Shows/Hides the maximum graph.
-
Save datalog: Saves the current scan measurements. You can see the data logs using the remote control application.
Constellation
Digital video often does not show signal impairment until it is too late due
to the small margin between acceptable quality and failure.
Constellation diagrams are an indispensable tool to help detect the presence
of noise, phase jitter, interference, and gain compression, all of which
impact overall signal quality and thus reduce the Modulation Error Ratio
(MER).
Ideally, each of the symbols in a constellation diagram should display a clean
dot indicating a perfect QAM signal.
The H30+/D+/D+Adv’s real-time constellation, allows the installer to assess
the size and shape of the build-up of dots indicative of problems that
contribute to bit errors leading to service disruption
Main window
Below is a capture of a Constellation window with a brief explanation of its
features:
Setup
Press to change Constellation options.
- Ter. Plan: Selected Terrestrial plan.
- Zoom: OFF, 1st, 2nd, 3rd, 4th. Select a quadrant of the constellation to be represented for a more detailed view. Select Zoom OFF for the full constellation.
- Tuning: Channel, Frequency
- Save datalog: Saves the current scan measurements. You can see the catalogs using the remote control application.
Voltmeter & Hum
H30+/D+/D+Adv measures the voltage present at the RF input.
The HUM measurement indicates the variation in the percentage of the video
carrier amplitude of the TV signal. This will help you diagnose those ground
and power interference problems that may result from a defective power supply
or faulty/overloaded power inserters.
Main window
Below is a capture of a Voltmeter & Hum window with a brief explanation of its
features:
Setup
Press to change Voltmeter & Hum options.
- T uning: Channel, Frequency.
- Save datalog: Saves the current scan measurements. You can see the data logs using the remote control application.
Learning plan
- Analyzes the input signal to the meter and automatically detect all channels.
- This feature automatically identifies the channels as either analog or digital and performs measurements on each.
- A bar graph is displayed with the height representing the power for digital channels and the level of the video carrier for the analog channels.
- The measurements made for analog channels are video carrier level and V/A. For digital channels, the measurements are power and C/N.
- The analog channels will have an extra, smaller white bar indicating the level of the audio carrier.
Main window
Below is a capture of a Learning Plan window with a brief explanation of its features:
Ingress Scan
Help identify reverse path problems before your customers are affected. Poorly
shielded coaxial cable and faulty terminations are important sources of
ingress noise which can easily add up in the return due to the large number of
subscriber-generated signals that are sent back to the headend. The combined
and amplified interference is often responsible for service disruption, so
having a good reverse path ingress scan tool is a must.
Main window
Below is a capture of an Ingress Scan window with a brief explanation of its
features:
Setup
Press to change the Ingress Scan options.
- Ingress frequencies: 5-42 MHz, 5-66 MHz, 5- 86 MHz, 5-206 MHz.
- Select the span of the graph.
- Ref. Level: Select the reference level of the bar graph
- Reset Data: Delete the max-hold and min-hold graph
Speed Test
Allows you to check your basic network performance parameters so you don’t
need to get your laptop out. This function attempts to connect to the server
(the server is selected automatically by the H30+/D+/D+Adv by location) and
checks the DHCP protocol and the connection to the Internet. If it is all
right, the H30+/D+/D+Adv makes a ping to the server and shows the delay times.
Finally, the H30+/D+/D+Adv makes a download and upload speed test. To start a
new test, press the OK button.
Main window
Below is a capture of a Speed Test window with a brief explanation of its
features:
MPEG
The H30+/D+/D+Adv’s MPEG feature will show the image of the selected service.
Main window
Below is a capture of a MPEG Info window with a brief explanation of its
features:
Setup
Press to change the Channel info options.
- Ter. Plan: Selected Terrestrial plan.
- Volume
- Info Service: On/Off info about the Service.
LT Monitoring
The H30+/D+/D+Adv’s Long Term Monitoring feature allows automatic monitoring
of the selected channel. The user must select the time interval elapsed
between two consecutive measurement shots. The H30+/D+/D+Adv automatically
performs all the measurements on the selected channel and saves them in
memory.
Once you enter the function, you must press the OK button to start measuring.
The H30+/D+/D+Adv will measure and store all the measurements while the user
does not leave the function.
Main window
Below is a capture of an LT Monitoring window with a brief explanation of its
features:
Configuration
Press to change LT Monitoring options.
- Measure delay: Select the time interval between two consecutive measure shots. The minimum value is 1 second.
- Measure 1, 2, 3: Allows select the three measures that the user wants to visualize in the main window:
Wi-Fi Scan (H30D+Adv)
Analyzes the Wi-Fi band and automatically detects all the Wi-Fi networks, as
well as their names and the power of the access point’s signal.
There are two different screens to display the information: List and Map.
List view
You can go through the list using and select one of the Wi-Fi networks to display it separately. If a Wi-Fi network has multiple access points, you will see several networks with the same name. If you select one of them, you will separate all the access points of that network. The first one in the list is the one you are connected to, which is the one that has more signal power at that point. Map view
Setup
Press to change the Wi-Fi Scan options.
- Band: Select band to scan (2.4GHz, 5GHz or both)
- Mode: Selects between Map or List View
- Sort: Only in List View mode. Allows to select how to sort the Wi-Fi list: name, level, or channels
- Save datalog: Saves the current scan measurements. You can see the datalogs using the remote control application.
Setup
Change main configuration settings:
- T er. Network: Aerial, Cable.
- Cable Standard: J.83-B / A.
- T er. Plan: Selected Terrestrial plan.
- L anguage: English, Español.
- Units: dBµV, dBmV, dBm
- Quality profiles: Trunk, Tap, End Line, Ground.
- Different thresholds are available for different testing locations.
- Analog Standard: Selects the standard for the analog channels and changes automatically the audio carrier to a value according to the selected standard.
- Audio Carrier: 4.5 MHz, 5.5 MHz, 6.0 MHz, 6.5 MHz.
- volume Network:
- Setup: Manual, Auto. When Setup Manual is selected, the user must set the IP, gateway and DNS. Gateway IPDNS
- Wi-Fi: Allows to connect the H30+/D+/D+Adv to a Wi-Fi network.
- Wi-Fi: On, Off
- Scan: When Wi-Fi is turned on, shows a list of all the found Wi-Fi networks.
As you can see in the image above, the list shows the name of the Wi-Fi
networks and indicates if the network is open or restricted, as well as the
protection access type.
To access to a restricted network, you must enter the password using and To
verify the password, find a red square behind the last character of the
password
and press
If you connect a mobile device (such as a mobile phone, tablet, etc.) and your H30+/D+/D+Adv to the same Wi-Fi network, you can use your mobile device to control your H30+/D+/D+Adv. You just have to download the H30+/D+/D+Adv app (available for IOS and Android)
- MAC: The MAC can be set automatically or user-selected
- Setup: Auto, Manual
- MAC: When Setup Manual is selected, the user must enter the MAC using navigation buttons and
- SSID: Shows the SSID of the H30+/D+/D+Adv
- BSSID: Shows the SSID of the H30+/D+/D+Adv
- IP: Shows the SSID of the H30+/D+/D+Adv
- Units System: Metric, Imperial
- Time and Date: Set the current time (hour and minutes) and date (day of the month, month, and year).
- Energy:
- Auto Suspension
- Auto shutdown
- Update firmware: ON, OFF
- When ON, every time the H30+/D+/D+Adv is connected to the internet, it will allow the user to update the firmware if a new version is available.
- Reset configuration: Resets the meter to factory settings.
- Licenses: Shows the options included in you H30+/D+/D+Adv
- About SW: Shows the firmware version
- About HW: Shows the product reference number, serial number and IP address.
IPTV (H30D+Adv.)
This menu provides the necessary measurements and parameters to guarantee a
correct reception of IPTV services.
IPTV functions
To achieve this, this menu has three functions:
Measurements
This function shows all the necessary measurements of the selected IPTV
channel.
Main Window
Below is a capture of an IPTV Measurements window with a brief explanation of
its feature:
Setup
Press to change IPTV Measurements options.
- Save Datalog: Saves the current IPTV measurements. You can see the datalogs using the remote control application.
Echoes (H30D+Adv.)
It is important to check that no echoes can cause problems in the reception of DVBT / T2 signals. This feature you allows to visualize the echoes of the received signal, helping the installer to minimize them as much as possible for optimal signal reception. In addition to the echoes graph, this function shows the channel power and MER measurements, as well as the FFT mode, the guard interval, and the Cell ID.
Main window
Below is a capture of an Ecos window with a brief explanation of its features:
Setup
Press to change Echoes options.
- Powering: Off, 13V, 18V, 24V.
- Tuning: Channel, Frequency
- Units: us, km
Firmware Update
Whenever your H30+/D+/D+Adv is connected to the internet, it will
automatically check if there is a newer firmware version. If it is so, an
arrow icon will appear at the top of the screen:
If the user wants to update the firmware, please select the function Update firmware in the Setup menu If there is a new firmware version, a message will be displayed when the user selects this function:
Press the OK button to automatically download and install the new firmware version.
Web Application
First of all, connect your H30+/D+/D+Adv to the network using the Ethernet connector or the Wi-Fi interface. Then you must find out the IP of your H30+ (see section 14.- Setup – Network/Wi-Fi). Then, type your H30+/D+/D+Adv IP in the address bar of your web browser and press Enter. Then you can see the home window of the H30+/D+/D+Adv web application:
Measurements
In this window, you can see all the catalogs saved in your H30+/D+/D+Adv. They
are grouped by date in a calendar:
To change the display mode from calendar mode to list mode, just click on the corresponding button placed at the menu bar:
Using the buttons placed at the top right of the screen, you can remove the selected Data logs or download them to your computer in .xls format (it will be generated a .xls file for each Datalog and they all will be downloaded together in a .zip file) Clicking on a Datalog of the list, the measurements of that Datalog will be displayed:
Plans
- In this window, you can see all the channel plans of your H30+/D+/D+Adv.
Terrestrial and Customer Channel Plans
-
The channel plans are grouped in three categories: Terrestrial and Customer.
-
The default Terrestrial channel plans are the standard channel plans.
-
These plans can be removed from the meter, but they can not be edited. However, you can make a copy of one of them to build a new customer channel plan from it.
The duplicated plans will appear in the Customer list automatically. -
The customer channel plans can be edited:
-
You can create a new channel plan from an existing one by clicking on the corresponding button. Or you can start from scratch, by clicking on the “New custom plan” button:
Plans repository
- The application also allows to configure the channel plans according to the geographic area you will use the meter. When you turn the meter on for the first time, you must select the languaje and then you must select the geographic area. So, the channel plans corresponding to that area will be available in your H30+/D+/D+Adv. But the user may add other standard channel plans corresponding to other geographic areas (this is specially helpful for those places located near the frontier between two areas). To do that, click on the “Channel plan repository” button :
- The channel plans added from the repository will
- be uploaded to your H30+/D+/D+Adv, but none of the channel plans in your meter will be removed.
IPTV
Using this function, the user can create and edit IPTV channels plans. Each
channel plan has only one plan, indicating the IP address and the port for
each channel:
Quality Profiles
Using the web application you can add new quality profiles. The H30+/D+/D+Adv
has two pre-defined quality profiles (head-end and outlet) that can not be
edited, but they can be duplicated. The duplicated quality profiles are saved
in the custom quality profiles, and the custom quality profiles can be edited.
Multiscreen
Using this feature you can control your H30+ remotely. For this to work, it is
necessary that the H30+/D+/D+Adv and the computer are connected to the same
LAN.
To access to this feature you must enter the password admin in the right top
part of the window. Then you will see the screen of the H30+/D+/D+Adv on your
computer:
Clone
Using this feature it is very easy to have the same configuration in all your
H30+/D+/D+Adv meters. You only have to export the configuration of the
H30+/D+/D+Adv that you wanto to copy, using the Export feature. This
configuration will be saved to a file on your computer. Then, connect other
H30+/D+/D+Adv where you want to copy the configuration to and select the
Import feature.
Update
In this section, you can update the firmware of your H30+/D+/D+Adv, as well as
install new licenses in your meter. If your H30+/D+/D+Adv is connected to the
internet, the system will detect automatically if your meter is already
updated by clicking on “Last firmware version”. If it is not, then you can
download the new version and install it automatically from this menu. If you
get the updated file from your distributor, you can install it on your
H30+/D+/D+Adv by clicking on “Manually updating firmware”.
Same with licenses: if your H30+/D+/D+Adv is connected to the internet, it
will detect newly purchased licenses automatically when you turn it on, and
will install them automatically. But if you get the licenses from your
distributor, you can install them on your device by clicking on “Add license”.
Maintenance
Always disconnect the unit before cleaning. Use only a mild solution of
detergent and water applied with a soft damp cloth. Dry thoroughly before use.
Do not use aromatic hydrocarbons or chlorinated solvents. These products may
damage the unit.
Do not use alcohol or alcohol-based products on the front panel, especially
the display. These products may damage the unit.
Technical support
For any questions, contact Technical Support at www.televes-
usa.com.
Before contacting Technical Support for repair, read the manual to ensure
proper use and attempt to RESET the unit to clear any problems.
Repair service
- Do not return the unit without first contacting Televes Technical Support.
- If the unit needs to be returned, Televes will arrange for free shipping. The unit will need to be appropriately packed for shipping.
- In compliance with IATA Regulations, when using our shipping service follow these instructions:
- Label the package.
- The equipment should fit as snugly as possible in the box. It is recommended to use the original packing materials.
- Attach the precaution label to the package.
- Failure to comply with these shipping requirements may result in the shipping agent rejecting the package.
Warranty
- A) Televes warrants, only to the original Purchaser, all Products be free from any defect in materials or workmanship for a period of one (1) year, six (6) months for the battery, from the date of original purchase, unless otherwise specified.
- (B) T eleves shall, free of charge and in its sole discretion, either repair, replace with a new or factory reconditioned equivalent, or refund the purchase price of the Product(s), that has been determined by Televes to be defective in material or workmanship, subject to the limits of this warranty.
(C) T his warranty excludes any inoperability resulting from:
- use or installation that is not in strict compliance with the written instructions and specifications;
- any modification or alteration performed by any third party not authorized in writing by Televes;
- service or repair performed by any third party not authorized in writing by Televes;
- misuse, abuse, intentional harm, or lack of reasonable care;
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>