SDC ED3000 Series Monitoring Switch Kit Instruction Manual
- June 5, 2024
- SDC
Table of Contents
SDC ED3000 Series Monitoring Switch Kit Instruction Manual
REMOVE TWO TOP ASSEMBLY SCREWS PLACE SWITCH ASSEMBLY AS SHOWN AND FASTEN
SCREWS.
WIRING SPECIFICATION
WHT – COM
YEL – N/O
ORG – N/C
5 AMP MAX.
Applications
Remote Latch Status Monitoring:
Retracting the latch by depressing the push pad provides an output signal for
local or remote visual and audible annunciation indicating forced entry or
unauthorized egress.
Access Control REX:
When connected to the Request-To-Exit input of a keypad, card or biometric
Access Controller, depressing the push pad and retracting the latch actuates
the Latch Status contact, shunting the control access control alarm to permit
authorized egress and/or releases the magnetic door lock for uninhibited
egress.
Magnetic Lock Release:
Where Access Controller with REX input is unavailable, the N/C contact of the
switch is wired in series between the power supply and fail safe magnetic
lock. Depressing the exit device pushpad retracts the latch, causing the
contact to open, thereby releasing the magnetic lock for uninhibited egress.
Mantrap Logic:
Provides N/O and N/C contacts required for 2 or more communicating doors for
Interlock and Mantrap applications.
Any suggestions or comments to this instruction or product are welcome. Please contact us through our website or email engineer@sdcsecurity.com