BLAUPUNKT ADH501 Dehumidifier air purification function Instruction Manual

June 5, 2024
Blaupunkt

ADH501 Dehumidifier air purification function

BLAUPUNKKT

Instruction Manual

Enjoy it.

air purifier purifier parts

Important notes

symbol parts

  • Store the device in a room where there are no permanent fire (e.g. operating gas equipment) and ignition sources (e.g. operating electric heater).
  • Store the device in a way that prevents mechanical damage.
  • Do not pierce or expose to fire.
  • Any person involved in servicing or working one refrigerant circuit should have a current valid certificate issued by an accredited organization that confirms their qualifications regarding the safe handling of refrigerants according to requirements. Servicing works must be performed only according to the device manufacturer’s guidelines.
  • Maintenance or repair works that require the assistance of other trained personnel should be performed under the supervision of a person competent in the use of flammable refrigerants.
  • Before performing any works on circuits containing flammable refrigerants, it is essential to perform a safety inspection to minimize ignition risks, Works should be performed according toa control procedure to minimize the risk of flammable gas or vapors being present during the works. All maintenance personnel and other persons working in the vicinity must be instructed in the nature of the work. Avoid working in confined spaces. Isolate the area around the workplace. Ensure that the area has been inspected by means of the control of flammable materials
  • Refrigerant may be odorless.
  • The device contains a determined amount (in grams) of R290 refrigerant (see the nameplate).
  • R290 isa refrigerant that meets the requirements of the
  • European directives concerning environmental protection.
  • Do not pierce any element of the refrigerant circuit.
  • When installing, operating or storing the device in a place without adequate ventilation, the room must be designed in such a way that no refrigerant will accumulate (in case of leakage). Refrigerant accumulation can cause a fire or explosion due to the presence of electric heaters, stoves or other sources of ignition.
  • Transport of equipment containing flammable refrigerant: see transport regulations.
  • Equipment symbol designation: see local regulations.
  • Disposal of equipment containing flammable refrigerant: see national regulations.
  • Equipment/devices storage: store in compliance with the manufacturer’s guidelines.
  • Storage of packed (unsold) equipment: The protective packaging of stored equipment should prevent the refrigerant from leaking in case of mechanical damage to the equipment. The maximum number of items of equipment to be stored together is specified in local regulations.
  • To achieve the utmost in enjoyment and performance, and in order to become familiar with its features, please read this, manual carefully before attempting to operate this product.
  • Before using this device read the instruction manual and follow the instructions inside, The manufacturer is not liable for any damages caused by the misuse of this device due to inappropriate handling. Please keep this manual for future reference.
  • This device is for domestic use only. Do not use for any other purposes.
  • The device should only be connected to an earthed socket with values corresponding to the values on the rating label
  • It is necessary to check, if total current consumption of all devices plugged into the wall outlet does not exceed the fuse in the circuit.
  • If you are using an extension cord, make sure that the total power consumption of the equipment plugged into the extension cord does not exceed the extension cord power rating. Extension cords should be arranged in such a way as to avoid tripping hazards.
  • Make sure the cable is grounded, 3-cores with a socket and an earth cable.
  • Do not let cord hang over edge of counter, or touch any hot
  • surface.
  • The device is not designed to be controlled via an external timer, separate remote control, or other equipment that can turn the device on automatically.
  • Before maintenance work always disconnect the unit from the power supply.
  • When unplugging the power cord from electrical outlet, hold it by the plug only and remove the plug carefully. Never pull the cable as it may cause damage to the plug or power cord.
  • Damage to the power cord or plug can lead to an electrocution hazard.
  • Never leave the product connected to the power source without supervision
  • Never put the power cable, the plug or the whole device into the water or any other liquids.
  • The device should be cleaned regularly complying with the recommendations described in the section on cleaning and maintenance.
  • Do not place the device near sources of heat, flame, an electric heating element or a hot oven.
  • Do not place on any other device.
  • This equipment can be used by children aged 8 years and over as long as supervision is provided. People with reduced physical or mental capabilities, as well as people with no previous experience of using this equipment must be supervised and made aware of the risks. The instruction manual should be used asa reference for the safe use of this, equipment. Children should not play with the equipment.
  • Children without ensured supervision should not be allowed to perform the cleaning and maintenance of equipment Additional precautions should be taken when using this device in the presence of children or pets.
  • Do not allow children to play with the device
  • Never use the product close to combustibles.
  • Never expose the product to atmospheric conditions such as direct sun light or rain, etc… Never use the product in humid conditions (like bathroom or camping house).
  • The power cable should be periodically checked for damage.
  • If the power cable is damaged the product should be taken toa professional service location to be fixed or replaced to prevent any hazards from arising.
  • Never use the product with a damaged power cable or if it was dropped or damaged in any other way or if it does not work properly. Do not try to repair the defected product by yourself as it can lead to electric shock. Always return the damaged device to a professional service in order to repair it.
  • All the repairs should only be performed by authorized service professionals. Any attempted unauthorized repairs performed can be a hazard to the user.
  • Only Original accessories should be used, as well as accessories recommended by the manufacturer. Using accessories which are not recommended by the manufacturer may result in damage of the device and may render the device unsafe for use.
  • Position the unit to ensure optimal air flow. The dehumidifier should be placed at least 30 cm away from walls, furniture, curtains, etc.
  • The air-intake and outlet ventilation grilles should be cleaned on a regular basis.
  • Do not cover the unit or the ventilation grilles. Do not place any objects on the unit. Do not use the unit near solvents, paints, insecticides or any other chemicals Do not place or use the unit in areas where it could be exposed to water, e.g. near showers, bathtubs, washbasins, etc.
  • Do not tilt the unit if you suspect that there is any water in the water tank.
  • Place the unit ona surface with a load-carrying capacity of at least 40 kg.
  • Do not use the unit in spaces smaller than 6m?
  • Do not insert any objects into the inlet or outlet grilles.
  • Do not direct the air flow towards animals or plants.
  • The water which accumulates in the dehumidifier is unsuitable for consumption (it is highly demineralized). It should be discharged into the waste-water system.
  • The unit can be used at temperatures 5-32°C. The unit is not designed to maintain a very-low humidity level (below 35%) for a prolonged period.
  • Before the first use, remove all protective elements such as cardboard, foil, and foamed polystyrene.
  • Wait at least 3 hours before switching on the unit following transportation, or ifit has been turned upside down (i.e. placed in non-vertical position)

Device is compliant with EU directives:
– Low voltage directive (LVD)
– Electromagnetic compatibility (EMC)
Device marked CE mark on rating label

When this crossed-out wheeled bin symbol is attached to a product it means that the product,
Is covered by the European Directive 2012/19/EU. Please inform yourself about the local
separate collection system for electrical and electronic products. Used appliance should be
delivered to the dedicated collecting points due to hazardous components, which may affect
the environment. Do not dispose this appliance In the common waste bin.

Environmental information
All unnecessary packaging has been omitted. We have tried to make the packaging easy to
separate into three materials: cardboard (box), polystyrene foam(buffer) and poly ethylene
(bags, protective foam sheet). Your system consists of material which can be recycled and
reused if disassembled by a specialized company. Please observe the local regulations
regarding the disposal of packaging materials, exhausted batteries and old equipment.

Your products is designed a manufactured with high quality materials and components,
ZY which canbe recycled and reused

TECHNICAL SPECIFICATIONS

Rated power: 290W(27°C, 60%)
Maximum power consumption: 460W(32°C, 90%)
Maximum current: 2,1 (32°C, 90%)
Voltage: 220-240 ~50Hz
Tank volume: 3,51
Air-flow rate 130m?/h
Refrigerant: R290/559
Maximum noise level:< 48dB(A)
Maximum condensation pressure: 1,2Mpa
Maximum evaporation pressure: 2,5Mpa
Recommended air filter: Blaupunkt ACCO32

  1. Control pane!
    1a, Display
    1b, Power on/off button
    1c, Fan-speed contro] button
    1d, TIMER button
    1e, Temperature button
    1f. Humidity-level button
    1h, Full-water-tank indicator

  2. Air-outlet grille

  3. Air-intake grille

  4. Water tank

  5. Handles

  6. Water outlet

  7. Tube for continuous water drainage (12 mm)

INSTRUCTIONS FOR USE

1. Start-up procedure

  1. Press the power on/off button (1b). The unit will switch on in the last-selected mode.

  2. Shutdown procedure
    Press the power on/off button (1b). The unit will switch off after awhile. Oo not interrupt the shutdown procedure by removing the plug from the electrical outlet.

  3. Adjustment of the alr-flow rate: to change the fan speed, press the fan-speed-control button (1¢) The icon will be illuminated in green in the standard mode and in red in the fast mode.

  4. Adjustment of the target humidity level: set the target alr-humidity level using the + and — buttons (1f); 359%-80% (at 5% increments) or the continuous-operation (CO) mode.

  5. Thermometer: to check the temperature, press the temperature button (1e), The temperature will appear on the display. After a while, or when you again press the temperature button (1e), the display will show the humidity level

  6. Full-tank indicator: if the tank is full of water, the dehumidifier will terminate the drying process and generate a signal tone, and the full tank icon (1h) will light up on the panel.

  7. Timer Delayed-start function: press the timer button (1d) while the unit is connected to the power supply. Each time you press the button, the set-time period will advance by one hour. The unit will switch on at the end of the set time period. The display will show the time remaining for the activation, To change the set time period, press the timer button (1d). The time indicator on the display will start flashing, While the time indicator is flashing, the set time period will advance each time you press the timer button (1) – stop at the desired time-until 24 hours is reached, and then it will return to zero. To deactivate the timer, set the time to 0. Shutdown timer: press the timer button (1d) while the unit is on. Each time you press the button, the set time period will advance by one hour. The unit will switch off. the end of the set time period. After you set the timer, the display will show for a while the time remaining to the shutdown, and then it will change to the humidity level. To check how much time remains to the shutdown, press the timer button (1d) again.

  8. Continuous water drainage To facilitate the continuous water drainage’s bypassing the water tank, insert the continuous-drainage tube (7) into the water outlet (6) and the other end of the tube into the drainage outlet,

  9. Automatic defrosting: if the unit’s components ate frosted, the dehumidifier will automatically switch into the defrost mode. The fan will remain on, and the compressor will switch off. Once the components have been defrosted, the dehumidifier will automatically return to the normal operating mode.

CLEANING AND MAINTENANCE

Before you start cleaning the product, ensure that it has been disconnected from the power supply and has fully cooled down.

Keep the inlet and outlet openings free of dust. Clean the outer surface of the unit witha slightly damp cloth, and then wipe it dry.

The water tank should be cleaned on a regular basis with a sponge and dishwashing liquid, then rinsed and wiped dry, again with the sponge.

Clean the air filter on a regular basis. To do this, remove the ai-intake grille and remove the filter. Clean the filter. The filter should be replaced every 3~4 months (depending on the water hardness)
Recommended air filter: the Blaupunkt ACCO32. Do not activate the unit without an air filter.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals