BLAUPUNKT WP1001 Black Water Pump Owner’s Manual

October 27, 2023
Blaupunkt

BLAUPUNKT WP1001 Black Water Pump

IMPORTANT NOTES

  • To achieve the utmost in enjoyment and performance, and in order to become familiar with its features, please read this manual carefully before attempting to operate this product.
  • Before using this device read the instruction manual and follow the instructions inside. The manufacturer is not liable for any damages caused by the misuse of this device due to inappropriate handling. Please keep this manual for future reference.
  • This device is for domestic use only. Do not use for any other purposes.
  • The device should only be connected to an earthed socket with values corresponding to the values on the rating label. It is necessary to check, if total current consumption of all devices plugged into the wall outlet does not exceed the fuse in the circuit.
  • If you are using an extension cord, make sure that the total power consumption of the equipment plugged into the extension cord does not exceed the extension cord power rating. Extension cords should be arranged in such a way as to avoid tripping hazards.Make sure the cable is grounded, 3-cores with a socket and an earth cable.
  • Do not let cord hang over edge of counter, or touch any hot surface.
  • The device is not designed to be controlled via an external timer, separate remote control, or other equipment that can turn the device on automatically.
  • Before maintenance work always disconnect the unit from the power supply.
  • When unplugging the power cord from electrical outlet, hold it by the plug only and remove the plug carefully.Never pull the cable as it may cause damage to the plug or power cord. Damage to the power cord or plug can lead to an electrocution hazard.
  • Never leave the product connected to the power source without supervision.
  • The device should be cleaned regularly complying with the recommendations described in the section on cleaning and maintenance.
  • Do not place the device near sources of heat, flame, an electric heating element or a hot oven. Do not place on any other device.
  • This equipment can be used by children aged 8 years and over under as long as supervision is provided. People with reduced physical or mental capabilities, as well as people with no previous experience of using this equipment must be supervised and made aware of the risks. The instruction manual should be used as a reference for the safe use of this equipment. Children should not play with the equipment. Children without ensured supervision should not be allowed to perform the cleaning and maintenance of equipment. Additional precautions should be taken when using this device in the presence of children or pets. Do not allow children to play with the device.
  • Never use the product close to combustibles.
  • Never expose the product to atmospheric conditions such as direct sun light or rain, etc… Never use the product in humid conditions (like bathroom or camping house).
  • The power cable should be periodically checked for damage. If the power cable is damaged the product should be taken to a professional service location to be fixed or replaced to prevent any hazards from arising.
  • Never use the product with a damaged power cable or if it was dropped or damaged in any other way or if it does not work properly. Do not try to repair the defected product by yourself as it can lead to electric shock. Always return the damaged device to a professional service in order to repair it. All the repairs should only be performed by authorized service professionals. Any attempted unauthorised repairs performed can be a hazard to the user.
  • Only Original accessories should be used, as well as accessories recommended by the manufacturer. Using accessories which are not recommended by the manufacturer may result in damage of the device and may render the device unsafe for use.
  • PDo not use the pump in the swimming pools. Do not use the pump in water bodies in which people are swimming.
  • The pump is used to transfer dirty water. Do not use the pump to transfer aggressive liquids such as petrol, greases, chemicals, salt water.
  • The pump is intended for transferring dirty water, in which the diameter of the impurities is not greater than the diameter indicated in the technical data. Larger impurities can damage the pump or block the flow.
  • The temperature of the pumped water must not exceed 35°C.
  • Do not use the pump to transfer drinking water. Leakage of lubricants may cause contamination of the water.
  • Do not turn on the pump which is not immersed in water (no water flow, dry-run).
  • Do not leave the pump at a negative temperature.
  • The pump is not designed for continuous operation. Do not use the pump for more than 8 hours continuously.
  • The pump must rest on the bottom or be secured with a rope to the handle. Do not hang the pump on the power cord or on the water drain hose.
  • Provide a space of at least 40 x 40 x 50 cm around the pump so that the float can freely move.
  • To ensure the pump’s reliable operation, do not immerse the pump base in the sludge, slit or other impurities.
  • When connecting the pump to the power supply source, make sure that the plugs and electrical sockets are not exposed to water flooding, and weather factors, such as rain.

Device is compliant with EU directives:

  • ow voltage directive (LVD)
  • lectromagnetic compatibility (EMC)

Device marked CE mark on rating label

When this crossed-out wheeled bin symbol is attached to a product it means that the product is covered by the European Directive 2012/19/EU. Please inform yourself about the local separate collection system for electrical and electronic products. Used appliance should be delivered to the dedicated collecting points due to hazardous components, which may affect the environment. Do not dispose this appliance In the common waste bin. Environmental informationAll unnecessary packaging has been omitted. We have tried to make the packaging easy to separate into three materials: cardboard (box), polystyrene foam (buffer) and poly ethylene (bags, protective foam sheet). Your system consists of material which can be recycled and reused if disassembled by a specialized company. Please observe the local regulations regarding the disposal of packaging materials, exhausted batteries and old equipment.
Your products is designed a manufactured with high quality materials and components, which can be recycled and reused

  1. Handle
  2. Body
  3. Base
  4. Float cable handle
  5. Universal connector

Technical data

Specification/Model WP4001 WP7501 WP1001 WP1601
Voltage 230 V ~ 50 Hz
Maximum power 400 W 750 W 1000 W 1600 W
Maximum flow 8000 l/h 11000 l/h 16000 l/h 20000 l/h
Maximum head 5,5 m 7,5 m 9m 10 m
Maximum working depth 7 m 7 m 7 m 8 m
Maximum water temperature 35 ºC
Maximum size of particles/impurities 35 mm
IPX protection class IPX8

INSTALLATION

  • The pump is intended for placement in the basement or other places exposed to flooding, or immersing in a water body. Make sure that the float can move freely, is not blocked by other objects or does not get stuck in the mud.
  • The device should work in a vertical position.
  • Make sure that the water can be drained to the desired location (check local regulations) before using the pump.
  • The pump is equipped with a universal connector which allows for the connection of hoses with different diameters. In case of connecting the 13 mm (1/2’’), 15 mm (5/8’’) or 19 mm (3/4’’) hose – cut off the narrowest part of the connector, screw a connector with the diameter of 24.5 mm onto the thread, then attach the hose quick-connector to the connector. In the case of 25 mm (1’’) hose – the hose must be screwed in and pressed onto the universal connector. Secure the hose with a clamp. In the case of 32 mm (1 ¼’’) hose, cut off the narrowest part of the connector together with the adjacent threaded segment. Screw and push the hose onto the remaining connector, then secure it with a clamp.
  • The above-mentioned components, such as the connector, quick-connector, clamp and hose – are not supplied with the device.
  • Always make sure that the pump, power cord and plug are not damaged before use. Make sure that the turn-on point and the turn-off point are correctly set. It is worth checking the operation of the pump in the barrel – whether the pump starts and stops when the float position is changed.

PUMP OPERATION

  • The attachment of the float cable in the handle determines the turn-on/turn-off height. The upper position determines when the pump will start operating. The lower position determines the pump turn-off moment.
  • Place the pump on a hard surface or use a rope attached to the pump handle to hang it in the reservoir. Connect the pump to the power supply.
  • Pump starting and stopping depend on water level and float position.

CLEANING AND MAINTENANCE

  • Make sure that the pump is disconnected from the power supply before proceeding with maintenance. If the pump is carried – wash the pump after each use.
  • When using the pump in one place, it is recommended to clean it once every 3 months.
  • The accumulated sludge can be washed with a pressure washer. Wipe the components with a cloth. Do not use aggressive detergents, solvents or sharp objects.
  • Do not use the pump when the temperature is below 0°. Store the pump in a place where the temperature is higher than 0°.
  • It is recommended to use the pump at least once every 3 months.

Competence Center
2N-Everpol Sp. z o.o. ul. Pulawska 403A 02-801 Warsaw, Poland
Phone: + 48 22 688 08 00
e-mail: [email protected]
www.blaupunkt.com
W przypadku pytar’i lub problem6w prosimy o kontakt z naszym serwisem. In case of questions or problems please contact our service.
Tel. 00 48 22 688 08 33
Email:[email protected]

All rights reserved. All brand names are registered trademarks of their respective owners. Specifications are subject to change without prior notice.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Blaupunkt User Manuals

Related Manuals