Nedis AIPU100CWT Air Purifier User Manual
- June 5, 2024
- nedis
Table of Contents
AIPU100CWT Air Purifier
User Manual
Preface
Thank you for purchasing the Nedis AIPU100CWT.
This document is the user manual and contains all the information for correct, efficient and safe use of the product.
This user manual is addressed to the end user. Read this information carefully before installing or using the product.
Always store this information with the product for use in the future.
Product description
The Nedis AIPU100CWT is an air purifier with a display.
Intended use
The product is intended to purify the air in a room.
The purifier can filter the air in a room up to 20 m2.
Any modification of the product may have consequences for safety, warranty and proper functioning.
Specifications
Product
|
Air purifier
---|---
Article number
|
AIPU100CWT
Dimensions (l x w x h)
|
215 Ø x 460 mm
Applicable area
|
< 20 m2
Clean air delivery rate
|
200 m3 / h
Noise level
|
32 – 50 dB
Operating temperature
|
-10 °C – 40 °C
Operating humidity
|
< 95 % RH
Power supply
|
220 – 240 VAC ~ 50 / 60 Hz
Rated power
|
35 – 40 W
Standby power
|
< 0.5 W
Main parts (image A)
A
1. LED display
2. LED light
3. Air outlet
4. Power cable
5. Air inlet
6. Air filter
7. Filter cover
Interface (image B)
B
1. On/off button
2. Sleep mode button
3. Fan speed indicator
4. Fan speed button
5. Light button
6. Anion button
7. Fan speed indicator
8. Filter indicator
Safety instructions
WARNING
- Read the instructions before use.
- Only use the product as described in this manual.
- Do not connect a bound cable to the power outlet.
- Do not place the product near gas, an electric burner or a heated oven.
- Do not use a damaged product.
- Do not use the product in wet or damp environments.
- Only use the product indoors.
- If servicing is needed, refer to qualified personnel.
- Do not insert any objects into the product.
- Do not cover ventilation openings.
- Do not use the power cable to carry the device.
- Do not let the power cable touch hot surfaces.
- Do not place items on top of it.
- Do not unplug the product by pulling on the cable. Always grasp the plug and pull.
Installation
Check that all parts are present and that no damage is visible on the parts. If parts are missing or damaged, contact the Nedis B.V. service desk via the website: www.nedis.com.
- Removing the packaging
1. Open A 7.
2. Take out A 6.
3. Remove the packaging and reïnstall A 6.
4. Close A 7.
- Do not place the product within 40 cm of the wall to ensure proper operation.
5. Plug A 4 in a power outlet.
Use
Using the product
1. Press B 1 to switch on the product.
2. Press B 4 to increase / decrease the fan speed.
- B 3 indicates the selected fan speed.
3. Optionally, choose one of the following:
- B 2 to select ‘sleep’ .
- B 6 to select ‘anion’.
- Keep the windows closed while the product is switched on.
Set sleep mode
1. Press B 2 to select sleep mode.
- In sleep mode, the product operates as quiet as possible.
2. Press B 2 or B 1 to exit this mode.
Set anion mode
1. Press B 6 to select anion mode.
- The product releases millions of anions per second.
2. Press B 6 or B 1 to exit this mode.
Troubleshooting
Problem
|
Solution
---|---
The product does not switch on.
|
Connect to a power outlet.
Check if the power cord is damaged.
Make sure A 7 is closed.
The product is making strange noises.
|
Make sure A 6 is placed in the correct way.
Press B 4 to increase the speed
Replace A 6.
Poor purification quality.
|
Do not block ventilation openings and make sure that there is enough space around the product.
Make sure A 6 is placed in the right way.
Make sure the room is smaller than 20 m2.
Replace A 6.
The product spreads an unpleasant odour.
|
Make sure the room has a relative humidity below 85 %.
Replace A 6.
B 8 illuminates after replacing A 6.
|
Press and hold B 8 for 3 seconds to reset.
Maintenance
- Clean the product regularly with a soft, clean, dry cloth. Avoid abrasives that can damage the surface.
- Do not use aggressive chemical cleaning agents such as ammonia, acid or acetone when cleaning the product.
To clean the product:
- Unplug the product before servicing.
- Clean A 6 at least once a month with a vacuum cleaner.
- Do not clean with water or other liquids.
Check filter indicator
1. When B 8 illuminates, check A 6.
2. When dusty, clean as described in ‘To clean the product’.
Replace the filter
- Replace the filter every 6 – 8 months.
- See ‘Removing the packaging’ for information on how to remove and place A 6.
Warranty
Any changes and/or modifications to the product will void the warranty. We accept no liability for damage caused by improper use of the product.
Disclaimer
Designs and specifications are subject to change without notice. All logos, brands and product names are trademarks or registered trademarks of their respective owners and are hereby recognized as such.
Disposal
|
This symbol indicates that this product should not be thrown away with other household waste throughout the EU. To prevent possible harm to the environment or human health by uncontrolled waste disposal, you are responsible for recycling it so that it can promote the sustainable reuse of raw materials. To return your used product, you can use the regular return and collection systems or contact the store where the product was purchased. They can recycle this product for the environment
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>