Micron Electronics AIRE100V LTE Tracker User Manual

June 5, 2024
Micron Electronics

Micron Electronics AIRE100V LTE Tracker User Manual

Introduction

AIRE100V is a powerful LTE Tracker which is designed as Emergency call equipment. It works on LTE B4/B13 with superior receiving sensitivity. Its location can be real time or schedule tracked by backend server or specified terminals. Based on the embedded wireless tracking protocol, AIRE100V can communicate with the backend server through LTE network, and transfer reports of emergency. Service provider is easy to setup their tracking platform based on the functional wireless tracking protocol.

The WIFI function will be activated and report the MAC addresses once the device is in alerting state. The BLE function will be activated and scan the third party BLE data or Beacon broadcast by custom setting or protocol.

RF 433.92MHz is used as a supervised short range RF communication link between the unit and the Base Station to determine if they are no longer in range with each other.

Product Overview

Appearance

Product Overview

Figure 1‐1

Buttons Interface Description

Button /USB Interface Description


KEY/interface

|

Description

Reset Key

| Power off     the Prime AIRE100V
Adapter|

Connected to a Power supply socket can power on AIRE100V

Function Key

| SOS mode

Feature Key

|

Play to do list audios.

TEST Key|

Test mode

LED Description

LED Description
Figure 1‐2

There are 3 LED lights in AIRE100V device, the description as following.

Light Event State
Function Key LED Function Key pressed Solid when pressed
Feature Key LED Feature Key pressed Solid when pressed
Test Key LED Test Key pressed Solid when pressed
Breath Light Test Key long press Breath effect

Getting Started

Parts List

Name

| Picture|

Remark

---|---|---

AIRE100V Base Station

| Parts List| The LTE Base Station.
AIRE100V adapter| Parts List|

It used to power on the AIRE100V.

Built-in Battery

The following items are suggestion for built‐in battery usage, please pay more attention.

  • The device is Emergency call equipment, which is designed to be used by adapter always plugged.
  • There is a 850mAh Lithium polymer battery integrated in device. The built‐in battery will only be used when the adapter unplugged.

Note: If the AIRE100V device is firstly used, please make sure the adapter of the device is plugged in the power supply socket.

AIRE100V Adapter

AIRE100V base station is connected with an AC Adapter.
The adapter is used for device power on, built‐in battery charging, which should be plugged in power supply socket at any time ( by end user).
Parts List
Figure 2‐1

Power on/Power off

Power on/Power off
Figure 2‐2

Power on:

  • Plug in the power adapter and power on.

Power off:

  • Unplugged the power adapter and press the Reset button.

Note: the user can not power off AIRE100V if the adapter is plugged.

Frequency

  • LTE: Band4, Band13
  • WIFI: 2412‐2462MHz
  • BLE: 2402‐2480MHz
  • 433: 433.92MHz

Trouble shooting and Safety info

Trouble shooting

Trouble

| Possible Reason|

Solution

---|---|---
Messages can’t be reported to the backend server by Mobile network.| APN is wrong. Some APN can not visit the internet directly.| Ask the network operator for the right APN.
The IP address or port of the backend server is wrong.| Make sure the IP address for the backend server is an identified address in the internet.
Unable to power off AIRE100V .| The function of power key was disabled by AT+GTFKS.| Enable the function of power key by AT+GTFKS.
Battery can not be charged| The battery has not been used for too long time and has been locked.| Using a external power source with 3.6V to 4.2V DC power supply to active the battery or apply for after sale help.

Safety info

The following items are suggestion for safety use, please pay more attention.

  • Please do not disassemble the device by yourself.
  • Please do not put the device on the overheating or too humid place, avoid exposure to direct sunlight. Too high temperature will damage the device or even cause the battery explosion.
  • Please do not use AIRE100V on the airplane or near medical equipment.

FCC Caution

This device complies with part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference.

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may Cause undesired operation.

§ 15.21 Information to user.
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

§ 15.105 Information to the user.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator& your body.

ISED RSS Warning:
This device complies with Innovation, Science and Economic Development Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

ISED RF exposure statement:
This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator& your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.