TESY CN 052 200 EI CLOUD W F Electric Panel Heater User Guide

June 5, 2024
TESY

TESY CN 052 200 EI CLOUD W F Electric Panel Heater User Guide

Quick start

Preened functions

Comfort mode

Activation

Deactivation

Predoomed functions

Eco mode

Deactivation

Sleep mode

Deactivation

Basic mode

Heating mode

Delay start function

Activation

Deactivation

Anti-frost mode

Temperature correction

Adaptive start

Reset

Keyboard lock

Open window

Day and time settings

Weekly program (24h/7h)

Tip-over switch

Device info

Sound

Wi-Fi

Quick menu

Comfort mode

Eco mode

Sleep mode

Delay start function

Weekly program (24h/7h)

IMPORTANT SAFETY MEASURES AND INSTRUCTIONS:

WARNING!

  • Please read this manual before operating the appliance and keep it at a safe place for future reference. In case the appliance is obtained by a new owner, it should be transferred together with its manual.
  • CAUTION: Children under 3 years of age should be kept away from the appliance unless they are under constant supervision. Children from 3 to 8 years of age are allowed to operate the on/off button ONLY, provided that the appliance is installed and ready for operation and such children have been supervised and instructed in safe operation of the appliance and they understand all related risks. Children from 3 to 8 years of age MUST NOT: connect the plug to power sockets, make adjustments, clean it or carry out user maintenance operations. This appliance can be used by children older than 8 years of age and by people with reduced physical, sensor and mental capabilities, as well as by people with insufficient experience and knowledge provided they are supervised or instructed in safe operation of the appliance and understand the related risks. Children should not be allowed to play with the appliance. Cleaning and user maintenance operations must not be carried out by children without supervision.
  • CAUTION: Some of the appliance parts may get very hot during operation and thus cause burns to users. In case there are children and vulnerable people in the room, special attention should be paid.
  • WARNING: Do not cover the appliance in order to prevent overheating!
  • The appliance must not be placed right under a socket box!
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  • Before connecting the appliance to the mains, check if the voltage indicated on its technical plate corresponds to the voltage of the electricity, supplied to your house.
  • This appliance shall be used only for the purpose it has been designed and intended for, i.e. heating of domestic premises. The appliance is not intended for commercial/industrial application. Every other use is to be considered improper, and therefore dangerous. The manufacturer doesn’t bear responsibility for damages arising from improper and irrational use. Non-adherence to these instructions would render the warranty invalid!
  • Do not leave your home while the heater is operating: make sure that the power switch is in OFF position (panel heaters with mechanical control).
  • Keep inflammable objects, such as furniture, pillows, bedding, paper, clothes, curtains etc. at a safe distance of at least 100 cm away from the panel heater.
  • Do not operate the appliance in areas of use or storage of combustible substances. Do not operate the appliance in areas of combustible media (for example in close proximity to inflammable gases or aerosols) – there is great risk of explosion and fire!
  • Do not insert and do not allow foreign objects to enter the ventilation openings (inlet and outlet) because this will cause electric shock, fire or will damage the appliance.
  • The appliance is not suitable for animal breeding. The panel heater is intended for domestic/indoor operation only.
  • When positioning the appliance, do not cover the safety grilles; do not hamper the incoming and outgoing air flow. All objects must be at a safe distance of at least 1 meter away from the appliance front and sides.
  • The most common reason for overheating is dust and fluff deposits in the appliance. Clean the ventilation openings on a regular basis with a vacuum cleaner, but before that it is very important to disconnect the heater from the mains.
  • Never touch the appliance with wet or moist hands – there is risk for your life!
  • The power socket should be accessible all the time in order to disconnect the power plug when needed as fast as possible! Never pull the power cord or the appliance itself in order to disconnect it from the mains.
  • PAY ATTENTION! Outgoing air gets heated during appliance operation (up to more than 100°С).
  • If you decide to stop using an appliance of this kind, it is recommended to make it unusable by cutting its power cord after you have disconnected it from the mains. It is advisable all possible risks related to the appliance to be secured, especially in relation to children that may play with out-of-use appliances.
  • Warning: Do not use this appliance with a programmer, counter or any other mechanism which could automatically turn on the heater – if the appliance is covered or positioned incorrectly there is a risk of fire.
  • Position the power cord in such a way that it does not obstruct the free movement of people and cannot be stepped on! Use only approved extension cords, which are suitable for this appliance, i.e. they have a compliance sign!
  • Never move the appliance by pulling its power cord; do not use the power cord for carrying other objects!
  • Do not bend the power cord and do not pull it against sharp edges; do not place the power cord on hot surfaces or open fire!

PACKING

  • After unpacking the appliance, check if its contents are intact and if it has not been damaged during transportation! In case a damage or incomplete delivery is found, contact your authorized retailer!
  • Do not dispose of the original packing box! It could be used for storage and transportation purposes in order to avoid damages during transportation!
  • Disposal of packing material should be done in the appropriate way! Children must be prevented from playing with polyethylene bags!

OPERATION AND INSTALLATION OF FEET SET

  • This panel heater is designed to be used indoors.

Important: In accordance with Regulation EU 2015/1188 implementing Directive 2009/125/EC this electric heating appliance is not intended for wall installation!
Important: In premises bigger than 45 m3, it is recommended to use a combination of 2 or more panel heaters.

  • Do not position the panel heater under a power socket or electricity connection box.

  • DO NOT install/operate the panel heater:
    1. in places where a draught is present, which could influence the control settings;
    2. right under a power socket;
    3. in “Volume 1” for bathrooms;
    4. in “Volume 2” if the control board can be reached by a person who is in a shower or in a bathtub;

  • Take the two feet out of the protective polyethylene bag, in case you intend to use the provided wheels set ­ take them out as well.

  • Either the feet only, or the feet combined with wheels, can be installed to the panel heater.

  • If you intend to use castor wheels, you will need to assemble the provided feet and wheels ­ take the foot with one hand and the wheel in your other hand. Insert the metal axis of the wheel into the special opening of the foot (there are special openings for the metal axes at the two ends of the foot) at a right angle ­ 90 °(between the axis and the horizontal of the foot).

  • Push the wheel and at the same time be careful not to injure yourself (the wheel is not capable to fix itself in one place and it rotates freely around its axis).

  • The pressure of your push must not exceed 20-30N (2-3kg). The wheel is to be considered safely attached if its axis restrictor has reached the cylindrical part in the foot opening.

  • Before starting the set installation check if the panel heater is disconnected from the power socket!

  • The feet are to be installed at the air inlets ­ it is correct them to be installed at the two sides ends of the panel heater in a symmetrical manner ­ at the same distance from the sides ends of the panel heater.

  • Mount the first foot ­ by inserting first the higher part of the foot into the panel heater (you should stand opposite of the face of the panel heater) ­ the part is lower than the front metal panel. Then you should take a Phillips screw-driver (not included in the product set) and screw in the two 3.5×9,5mm securing screws. The screw goes through the plastic foot and gets screwed into place in the metal body of the panel heater. You should repeat the same operation for the second foot.

  • The joint is secure in case the panel heater stands upright on the floor after its feet installation has been completed.

  • Do not use the power cord as a pulling rope in order to move the panel heater; any movement of the panel heater should be done when it is cold. Grasp by hand the upper metal part of the appliance and by directing it you should move it to the desired new location)!

  • Position the panel heater with installed feet on the floor and before connecting it to the power socket check if all instructions from the very beginning of this manual have been followed correctly (Important instructions and safety measures). The correct position is – the control panel should be at the top of the appliance and the feet – on the floor (If
    there are castor wheels installed – they should be on the floor)!

BATHROOM OPERATION

  • The panel heater must be installed in accordance with the normal trade practices and in compliance with the national legislation (EU electricity directives and regulations concerning special installations and places of operation including bathrooms, shower cabins HD60364-7-701(IEC 60364- 7-701:2006)).

  • In case this panel heater is to be used in a bathroom or other similar room, the following installation requirements must be observed: the panel heater is with IP24 protection (water drops protection). Hence it can be installed in “Volume 2” (see the diagram below) in order to avoid the risk of the control board (power switch and thermos regulator) being reached by a person who is in a shower or a bathtub. The minimum distance between the appliance and a water source should be not less than 1 meter and it is compulsory the appliance to be wall-mounted! If you do not feel sure about the installation of this panel heater in a bathroom, we recommend you to consult a professional electrician.

Note: If the above-mentioned instructions cannot be implemented, it is recommended to install the appliance in “VOLUME 3”.

  • In wet premises the power source must be installed at a height of at least 25 cm above the floor (bathrooms and kitchens).
  • The installation must be equipped with a safety fuse, and the distance between the fuse contacts in disconnected condition should be at least 3 mm.

Thank you for choosing CN052 panel heater. This is a product providing heating in winter depending on the consumers’ needs for comfortable room temperature. If operated and taken care of properly in accordance with these instructions, the appliance will provide you with many years of useful operation.

OPERATION INSTRUCTIONS

“Temperature correction for the sensor” function
Due to the specifics of the temperature profile in some premises there may be difference from the temperature shown on the display and the actually measured temperature in the various locations of the heating appliance in the room.

  • See the temperature shown on the display of the appliance
  • Measure the temperature at a place where the temperature is “comfortable” enough for you (usually at a height of 60 cm from the floor, in sitting position). If you find a difference within a range of ±4°, you can set the necessary correction in the convector’s menu (It is important to note that this function can be set only after the temperature has become the same all around the room, and depending on the room type, the minimum required time is 7 hours) by entering the temperature difference resulting between the value on the display and the actually measured temperature.

Note: This function is used with the purpose of providing better temperature comfort and energy saving for the user of the electric convector in the room which it is in. A temperature difference greater than ±4 °C from the measured temperature in a specific location in the room indicates that the room where you use the convector in is not well insulated or the temperature is not the same all around the room.

Example: a convector in a room on a stone floor ­ the convector displays 18° (the set temperature is 22°), the actually measured temperature (feeling of reached comfort temperature) is 22° at a height of 60 cm from the floor – > in this case the convector continues to overheat the room (this is a direct energy loss, but the convector cannot reach the set temperature because it measures the temperature at a low height close to the floor) and it will never switch off. In this case a temperature correction of +4° needs to be applied to the sensor, thus the convector will display 22° and it will start switching off, and eventually it will maintain the set temperature of 22°).
The normal status of the function is 0°C by default

Activation and deactivation of Temperature correction – /Quick start B4/
If the factory reset function is used, the temperature correction has to be set again. The factory setting of its value is 0°C.
Function Adaptive start Adaptive start is a function which predicts and initiates the optimal start of heating in order to reach the set-point temperature at the desired time;
Test according to user instruction / documentation. The function is tested in a room with a continuous heat demand of 50 – 60% with reference to the wattage of the test device. The product is working at a comfort temperature 23°C ± 3°C setpoint until stable conditions. This temperature is the reference comfort temperature “Ct”. Activate a set-back period of 7h +2h/-0h per 24h with a set- back of 4°C ± 1°C . The comfort period being 17 -2h/+0h hours. With the adaptive control activated – let the heater thermostat working during 4 periods (4 x 24 hours) of comfort and low setback cycles. After the latest low setback period finishes the comfort temperature “Ct” should be reached within ± 30 minutes deviation to the time target – with a maximal difference of ± 1⁰C from the reference comfort temperature “Ct” – Factory settings of the function is ‘’ON”

Activation and deactivation of Adaptive start – /Quick start B5/

RESET to default settings
If the customer wants reset the convector to factory settings.
Visualization on Display in “RESET” settings /Quick start B6/
After using the reset function, the following functions will be re-set:
– clock time
– temperature correction value 0⁰C
– function Anti-frost mode is activated
– adaptive start is activated
– weekly program – 24/7 is reset.

Open window/door function
Room temperature control with open window detection – the product is equipped with an integrated electronic device that reduces the heat output when detects an open window or door. A sensor is used to detect eventual drop in the room temperature. If the temperature falls more than 5°C, the convector will switch off by itself. Within 15 min the open window detection should turn the appliance off. When the room temperature rises by at least 0.5°C and the difference from the initial set point is below 5°C, the convector switches itself on with the settings already made. If the temperature does not rise for more than 60 minutes, the convector enters Standby mode. The function is allowed to be cancelled manually.
The function can be switched Off manually.

Activation and deactivation of Open window/door function – /Quick start B8/

Note: When the “Open window” function is enabled, the “Anti-frost” function does not work!

Keyboard lock (Protection from children)
When user turns on this function, all keys of the control panel remain locked.
Activation and deactivation of Keyboard lock – /Quick start B7/

Day and time ­ settings /Quick start B9/
First step or use after factory reset function

Weekly program (timer) 24hours/7days

Min 300 sets of time periods
Electronic thermoregulatory with weekly program (timer) 24/7 – electronic room temperature control plus weekly timer means the product is equipped with an electronic device, either integrated or external, which allows the product automatically to vary its heat output over a certain time period. In relation with a certain required level of indoor heating comfort. It allows the setting of timing and temperature levels for a full week. During the 7-day period the settings must allow a variation on a day-to-day basis;

Activation and deactivation of Weekly program – /Quick start B10/
There have three options /Quick start B10/:
– CREATE PROGRAM
– ERASE PROGRAM
– VIEW PROGRAM
The temperature of 22 ˚C started at 12.30 to 15.00 on Sunday. The convector will heat till reach the settings of the next given point.

If the TIME PERIOD is empty (no time set) – visualization should be

– One step back – with single pushing of ON/OFF button .
– No limit of time periods – step is 0.5 hour (30 minutes).
– Adaptive start function is switched on by default.

Built in tip-over switch /Quick start B11/ – if the convector tilts with more than 45° or falls down, the power must switch Off and indicate on display ‘’tilt’’. After restoring the device to its normal position, operation of the last set function must continue.

Function Wi-Fi
Activation and deactivation of Wi-Fi Function and Wi-Fi Local Function – / Quick start B14/

Work mode of display:
When pressed – backlight intensity – 100%; after 5s – OFF

Sound option
Activation and deactivation of sound function – /Quick start B13/

Device info
Visualization on Display in “Device info” /Quick start B12/
– ID
– MAC address
– Firmware version

Quick menu /Quick start C 1 -5/
Push the “Mode” button to start quick already configured program.
Content function:
– Comfort
– Eco
– Sleep
– Delay start
– Weekly schedule
Exit from the any mode – with single pushing of ON/OFF button

Errors mode:
If the display shows “t1” or “t2“, this means that the self- diagnostic system has found a problem with the temperature sensor. “t1” indicates a disconnected cable at the sensor, while “t2” indicates short circuit at the sensor. In this case the electric convector will be automatically switched off and it can be switched on again only after the problem has been fixed. The problem has to be handled by a qualified specialist.

DISCONNECTION FROM THE POWER SUPPLY:
If the electric convector is disconnected from the mains, this will not affect the set temperature and the mode of operation which has been active prior to its disconnection. If for example the convector has been in “Heating” mode, after it has been disconnected and reconnected to the mains, it will continue
operating in the same mode with the same set temperature.

The principle of operation of the electric convector with energy-independent memory is to store the settings for 120 minutes guaranteed, and up to 180 minutes not guaranteed.

If the time is more than 120 min the appliance going to Stand by mode.

PROTECTION

  • The appliance is equipped with a safety thermos turn-off device, which automatically turns the heater off in cases of extreme temperature of the panel heater /i.e. overheating of the appliance/.
  • The safety thermos turn-off device will automatically restore the heater operation when the temperature of the appliance falls below the permissible ultimate values.

CLEANING

  • It is compulsory first to turn off the appliance through its power switch and to disconnect it from the power socket. Before starting the cleaning session you should wait until the panel heater cools down in a disconnected state.
  • Clean the heater body with damp cloth, vacuum cleaner or a brush.
  • Never immerse the appliance into water – there is danger for your life from electric shock!
  • Never use gasoline, thinner or hard abrasive products to clean the appliance, because they will damage the appliance coating.

STORAGE

  • Before putting the panel heater away let it cool down after you have disconnected it from the power socket
  • Use the appliance original packing to store it, if the panel heater will not be in use for a long period of time. By storing the product in its original packing you protect it from excessive dirt and dust accumulation.
  • Never put a hot panel heater in its packing!
  • It is necessary the product to be stored at a dry and dark place, protected from direct sun light.
  • It is explicitly forbidden to store the panel heater in damp and wet premises.

MAINTENANCE OPERATIONS OF THE APPLIANCE

  • In case of appliance malfunction, please contact the authorized service center closest to your location. /service centres are indicated in appliance warranty documents/.
  • Important: In case of a claim and/or violation of your consumer rights, please contact the supplier of this appliance at the indicated locations or via the Internet page of the company: www.tesy.com

DIMENSIONS OF HEATED VOLUME AND HEATED AREA OF A ROOM / APPLIANCE MODELS

TABLE 2: INFORMATION REQUIREMENTS FOR ELECTRIC LOCAL SPACE HEATERS

TESY Ltd 48 Madara Blvd, Shumen, 9700, Bulgaria
16 Operation and Storage Manual of Panel Heater

TROUBLESHOOTING

TESY Ltd – Head office 1166 Sofia, Sofia Park, Building 16V, 2nd Floor PHONE: +359 2 902 6666, FAX: +359 2 902 6660,
office@tesy.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals