MEAN WELL IRC3 Power Inverter Remote Control Owner’s Manual

June 3, 2024
MEAN WELL

MEAN WELL IRC3 Power Inverter Remote Control

MEAN-WELL-IRC3-Power-Inverter-Remote-Control-product

Features

  • Wall-mount and control panel are acceptable
  • Built-in ON/OFF button
  • Digital meters for battery level, output load level, and operating status on the remote control panel
  • LED indicators for remote ON/OFF, abnormal and power-saving mode
  • Remote panel with 10FT cable length, optional for 25FT or 50FT
  • Connect directly to the remote socket of the inverter, no power supply is needed 3 years warranty
  • Description: IRC1/IRC2/|RC3 is the monitoring and control unit used for the inverter series. It can decode the RS-232 signal sent by the inverter series and display it through digital meters. IRC1 / IRC2/ IROc3 can also turn the ON/OFF of the inverter remotely which makes the basic control more easily.

SPECIFICATION

MODEL IRC1 IRC2 IRC3

OUTPUT

| DIGITAL METER| —–| Display the battery level, output load level, and operating status of inverter unit
CONTROL OUTPUT| Remote ON/OFF for inverter unit
LED INDICATOR| Remote turn ON(Green) ; Remote turn Off(Orange) ; Abnormal (Red) ; Saving mode (Orange flash)




FUNCTION

| REMOTE ON/OFF CONTROL| The controlled inverter unit can be turned ON/OFF on the remote control panel for IRC1 / IRC2 / IRC3
POWER SAVING CONTROL| Power saving enable / disable activation



SUITABLE SERIES

| TS-700 / 1000 / 1500 / 3000

TN-1500 / 3000

NTS-750 / 1200 / 1700 / 2200 / 3200

NTU-1200 / 1700 / 2200 / 3200

| TS-700 / 1000 / 1500 / 3000

NTS-750 / 1200 / 1700 / 2200 / 3200

NTU-1200 / 1700 / 2200 / 3200

| TN-1500 / 3000

NTS-750 / 1200 / 1700 / 2200 / 3200

NTU-1200 / 1700 / 2200 / 3200



ENVIRONMENT

| WORKING TEMP.| -20 ~ +50℃
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes


EMC

| EMC EMISSION| Compliance to BS EN/EN55032 class A, BS EN/EN61000-3-2,3, FCC PART 15 class A
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,6,8
OTHERS| DIMENSION| 755521mm (LWH)
PACKING| 0.26Kg; 24pcs/7.3Kg/1.75CUFT
NOTE| 1.  The remote control can not re-power for the inverter at abnormal status.

2.  The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitudes higher than 2000m(6500ft).

Mechanical Specification

MEAN-WELL-IRC3-Power-Inverter-Remote-Control-
fig-1

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals