WISI VX45E In-house amplifier local feed Instructions

June 5, 2024
WISI

WISE HOME LINE
VX 45E
In-house amplifier local feed
Operating instructions
WISI VX45E In-house amplifier local feed


  • Very compact housing
  • Rotary switches for attenuator and equalizer
  • High output level (107 dBµV) channel load
  • External test socket at in -and output
  • All settings without interruption of service
  • Precise and readable alignments

****Services and repairs should only be carried out by experts.
Pay attention to live parts or wires! Switch off the power supply.
Tighten housing screw (approx. 1.3 Nm)

Settings

WISI VX45E In-house amplifier local feed - Settings

Block diagram

WISI VX45E In-house amplifier local feed - Block
diagram

Drilling dimensions

Legende
DS = Down Stream
ATT = Attenuator
EQ = Equalizer

Specifications

Downstream

Frequency range 47-862 MHz
Gain 36 dB
Attenuator Jumper 0 / 5 dB

1 dB steps rotary switch 0-15 dB
Equalizer| 1.5 dB steps rotary switch 0-22.5 dB
Interstage
– Attenuator – Equalizer| Jumper 0/6 dB
Jumper 0/6 dB
Output level -CSO
-CTB| CENELEC 42 ch / 6 dB slope 107 dBpV

60 dB
60 dB
Noise figure| < 7.5 dB
Test points| -20 dB

General

Operating voltage 230 VAC ±10 % / 50/60 Hz
Power consumption < 5 W
Impedance, connector 75 il / F
Screening factor Class A
Ambient temperature -20°C…+55°C
Storage temperature -25°C…+75°C
Max. humidity non-condensing 95 ok
Dimensions WxHxD 163 x 90 x 47 mm
Lightning protection DS input 1 kV – EN61000-4-5 1,2/50 ps pulse

WISI Communications GmbH & Co. KG Empfangs- und Verteiltechnik
Wilhelm-Sihn-Straße 5-7, 75223 Niefern-Öschelbronn
Tel . 07233 / 66-292, Fax. 66-320,wisigroup.com
… a link to the future
Technische Änderungen und Druckfehler vorbehalten!
Technical Modifications reserved. WISI cannot be held liable for any printing error.
05/08

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

WISI User Manuals

Related Manuals