MEAN WELL HRP-150N 150W Single Output with PFC Function Instruction Manual

June 5, 2024
MEAN WELL

150W Single Output with PFC Function
Instruction Manual 

MEAN WELL HRP-150N 150W Single Output with PFC Function -
ICON

Features

  • Universal AC input / Full range
  • Built-in active PFC function, PF>0.95
  • 250% peak power capability
  • High efficiency up to 89%
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Cooling by free air convection
  • 1U low profile 38mm
  • Built-in remote sense function
  • 5 years warranty

Applications

  • Industrial automation machinery
  • Industrial control system
  • Mechanical and electrical equipment
  • Diagnostic or biological facilities
  • Test or measurement systems
  • Telecommunication equipment

■ GTIN CODE
MW Search :https://www.meanwell.com/serviceGTIN.aspx

Description
HRP-150N is a 150W single output type AC/DC power supply. This series operates for 85-264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by free air convection, working for the temperature up to 70°C without cover. Moreover, HRP-150N provides 250% short-duration peak power for motor applications and electromechanical loads requiring much higher power during start-up.
Model Encoding

HRP Output voltage(12/24/36/48V)
150N Rated wattage
24 Series name

 SPECIFICATION

MODEL| HRP-150N- 2| HRP-150N-24| HRP-150N-36| HRP- 150N-48
---|---|---|---|---
OUTPUT| DC VOLTAGE| 12V| 24V| 36V| 48V
RATED CURRENT| 13A| 6.5A| 4.3A| 3.3A
CURRENT RANGE| 0 ~ 13A| 0 ~ 6.5A| 0 ~ 4.3A| 0 ~ 3.3A
RATED POWER| 156W| 156W| 154.8W| 158.4W
RIPPLE & NOISE (max.) Note.2| 120mVp-p| 150mVp-p| 200mVp-p| 240mVp-p
VOLTAGE ADJ. RANGE| 10.2 ~ 13.8V| 21.6 ~ 28.8V| 28.8 ~ 39.6V| 40.8 ~ 55.2V
VOLTAGE TOLERANCE Note.3| ±1.5%| ±1.5%| ±1.5%| ±1.5%
LINE REGULATION| ±0.3%| ±0.2%| ±0.2%| ±0.2%
LOAD REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 3000ms, 50ms/230VAC 3000ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)| 16ms/230VAC 16ms/115VAC at full load




INPUT

| VOLTAGE RANGE ote.4| 85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.95/230VAC         PF>0.98/115VAC at full load
EFFICIENCY (Typ.)| 88%| 88%| 89%| 89%
AC CURRENT (Typ.)| 1.7A/115VAC  0.9A/230VAC
INRUSH CURRENT (Typ.)| 35A/115VAC 70A/230VAC
LEAKAGE CURRENT| <1mA / 240VAC
PROTECTION| ****

OVERLOAD

| Normally works within 105 ~ 200% rated output power for more than 5 seconds and then shut down o/p voltage, re-power on to recover
Constant current limiting for output power >280% rated for more than 5 seconds and then shut down o/p voltage, re-power on to recover
OVERVOLTAGE| 14.4 ~ 16.8V| 30 ~ 34.8V| 41.4 ~ 48.6V| 57.6 ~ 67.2V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT| WORKING TEMP.| -40 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -50 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.04%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
OPERATING ALTITUDE Note.6| 5000 meters







SAFETY & **EMC**

(Note 5)

| SAFETY STANDARDS| UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004, AS/NZS 62368.1 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC  I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032| Class B
Radiated| BS EN/EN55032| Class B
Harmonic current| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| —–





EMC IMMUNITY

| BS EN/EN55035 , BS EN/EN61000-6-2(BS EN/EN50082-2)
Parameter| Standard| Test Level / Note
ED| BS EN/EN61000-4-2| Level 3, 8KV air; Level 2, 4KV contact
RF field| BS EN/EN61000-4-3| Level 3, 10V/m
EFT/ Burst| BS EN/EN61000-4-4| Level 3, 2KV
Surge| BS EN/EN61000-4-5| Level 4, 4KV/Line-FG; 2KV/Line-Line
Conducted| BS EN/EN61000-4-6| Level 3, 10V
Magnetic Field| BS EN/EN61000-4-8| Level 4, 30A/m
Voltage Dips and Interruptions| BS EN/EN61000-4-11| 95% dip 0.5 periods, 30% dip 25 periods, 95% interruptions 250 periods
**OTHERS| MTBF| 1740.3K hrs min.     Telcordia SR-332 (Bellcore) ; 221.7K hrs min.       MIL-HDBK-217F (25℃)
DIMENSION| 1599738mm (LWH)
PACKING**| 0.54Kg; 24pcs/12.96Kg/0.9CUFT

NOTE

  1. All parameters NOT specially mentioned are measured at 230VAC input rated load, and 25℃ of ambient
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 1uf & 47uf parallel capacitor.
  3. Tolerance: includes set up tolerance, line regulation, and load
  4. Derating may be needed under low input Please check the derating curve for more details.
  5. The power supply is considered a component that will be installed into a final All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to  EMI testing of component power supplies. (as available on http://www.meanwell.com)
  6. The ambient temperature derating of 5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitudes higher than 2000m(6500ft).

※ Product Liability Disclaimer For detailed information, please refer to https://[www.meanwell.com/serviceDisclaimer.aspx](http://www.meanwell.com/serviceDisclaimer.aspx)

**Block Diagram

**

PWM fosc: 90KHz

MEAN WELL HRP-150N 150W Single Output with PFC Function -
fIG

Derating Curve

MEAN WELL HRP-150N 150W Single Output with PFC Function - fIG
1

Output Derating VS Input Voltage

MEAN WELL HRP-150N 150W Single Output with PFC Function - fIG
2

Function Manual

  1. Remote Sense
    The remote sensing compensates for voltage drop on the load wiring up to 0.5V.
    MEAN WELL HRP-150N 150W Single Output with PFC Function - fIG
2

  2. Peak Power
    MEAN WELL HRP-150N 150W Single Output with PFC Function - fIG
3P av: Average output power (W)
    P pk: Peak output power (W)
    P npk: Non-peak output power(W)
    P rated: Rated output power(W)
    t : Peak power width(sec)
    T : Period(sec)
    MEAN WELL HRP-150N 150W Single Output with PFC Function - fIG
4

For example (12V model) :
Vin = 100V Duty_max = 25%
Pav = Prated = 156W
Ppk = 300W
t ≤ 5 sec
T≧ 20 sec
MEAN WELL HRP-150N 150W Single Output with PFC Function - fIG
5P npk≤ 108W

Mechanical Specification

Terminal Pin No. Assignment :

Pin No. Assignment Pin No. Assignment
1 AC/L 4,5 DC OUTPUT -V
2 AC/N 6,7 DC OUTPUT +V
3 FG

Connector Pin No. Assignment (CN100) :
HRS DF11-6DP-2DSA or equivalent

Pin No. Assignment Mating Housing Terminal
1 -S HRS DF11-6DSor equivalent HRS DF11-**SC or equivalent
2 +S
3-6 NC

Installation Manual
Please refer to : http://www.meanwell.com/manual.html

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals