Features

  • Constant current design
  • Protections: Short circuit/Over voltage
  • Fully isolated plastic case
  • Small and compact size
  • Cooling by free air convection
  • Class II power unit, no FG
  • No load power consumption <0.5W
  • IP42 design
  • Suitable for LED lighting and moving sign applications
  • 100% full load burn-in test
  • Low cost / High reliability
  • 2 years warranty

Applications

Suitable for LED related fixture or appliance (such as LED Decoration or Advertisement devices) (Note.7)

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

Description

APC-16E series is one 16W AC/DC constant current mode single output LED power supply. It accepts input 180 264VAC and provides two models with different output current, 350mA and 700mA, respectively, that the small wattage LED applications employ the most frequently. Exploiting Class I design (without FG pin) and adopting the 94V-0 flame retardant plastic enclosure, APC-16E ideally fits the entry-level LED applications.

Model Encoding

SPECIFICATION

MODEL APC-16E-350 APC-16E-700



OUTPUT

| RATED CURRENT| 350mA| 700mA
DC VOLTAGE RANGE| 12~48V| 9~24V
RATED POWER| 16.8W| 16.8W
RIPPLE & NOISE **(max.)Note.2| 300mVp-p| 250mVp-p
VOLTAGE TOLERANCE Note.3| ±5.0%
CURRENT ACCURACY| ±8.0%
LINE REGULATION| ±1.0%
LOAD REGULATION| ±3.0%
SETUP, RISE TIME| 500ms, 200ms / 230VAC at full load
HOLD UP TIME (Typ.)**| 20ms/230VAC at full load





INPUT

| VOLTAGE RANGE Note.4| 180 ~ 264VAC        254 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.5/230VAC at full load
EFFICIENCY (Typ.)| 83%| 82%
AC CURRENT| 0.3A/230VAC
INRUSH CURRENT (Typ.)| COLD START 45A(twidth=210μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 13 units (circuit breaker of type B) / 23 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| 0.25mA / 240VAC
PROTECTION| OVER VOLTAGE| 50.4~ 60V| 27.6~ 33.5V
Protection type : Shut off o/p voltage, clamping by zener diode



ENVIRONMENT

| WORKING TEMP.| -30 ~ 70℃(Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.2%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes


SAFETY & EMC

(Note 5)

| SAFETY STANDARDS| IP42,BS EN/EN 62368-1 approved
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC
ISOLATION RESISTANCE| I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032,BS EN/EN61000-3-2,BS EN/EN61000-3-3
EMC IMMUNITY| Compliance to BS EN/EN55024,BS EN/EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV)


OTHERS

| MTBF| 6106.2K hrs min.      Telcordia SR-332 (Bellcore) ;     1014.0K hrs min.      MIL-HDBK-217F (25℃)
DIMENSION| 774029(LWH)
PACKING| 0.1Kg; 120pcs/14Kg/1.06CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.

  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

  3. Tolerance: includes set up tolerance, line regulation and load regulation.

  4. Derating may be needed under low input voltage. Please check the static characteristic for more details.

  5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
    complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

  6. The ambient temperature derating of 3.5 C/1000m with fanless models and of 5 C/1000m with fan models for operating altitude higher than 2000m(6500ft).

  7. This product is not intended for LED lighting luminaire applications in the EU.(ln the EU the LPF/NPF/XLG series are recommended.)

  8. For any application note and IP water proof function installation caution, please refer our user manual before using.
    https://www.meanwell.com/Upload/PDF/LED_ENpdi
    X Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Product Liability Disclaimer For detailed information , please refer to https :// www . meanwell . com / serviceDisclaimer . aspx

Mechanical Specification

MEAN-WELL-APC-16E-Series-16W-Single-Output-fig3

Block Diagram

MEAN-WELL-APC-16E-Series-16W-Single-Output-fig4

Derating Curve

MEAN-WELL-APC-16E-Series-16W-Single-Output-fig5

Static Characteristics

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals