MILOO 107002D940 Electronics Mediled 2.0 Instruction Manual

June 13, 2024
MILOO

MILOO 107002D940 Electronics Mediled 2.0

Product Information

  • Product Name: MEDILED 2.0
  • Product Type: Luminaire
  • Intended Use: Designed to illuminate interiors of health care facilities featuring increased hygienic requirements; can be installed in ARMSTRONG Q-CLIP F ceiling systems
  • Installation Procedure: Flush-mounted or surface-mounted
  • Options Available: ECO and NEO
  • IP Rating: IP40 (for flush-mounted) and IP65 (for surface-mounted)
  • Manufacturer: MILOO-ELECTRONICS Sp. z o. o.

Product Usage Instructions

  1. Installation should be carried out by a duly authorized person.
  2. Always switch off the supply voltage before proceeding with any work on the luminaire.
  3. When installing luminaires in a coffered ceiling, check the load bearing capacity of the ceiling and the weight of the luminaires to be installed.
  4. To relieve the strain on the ceiling, it is recommended to fix the MEDILED 2.0 luminaires on 2 to 4 wires (not included) to a solid ceiling or a permanent construction.
  5. For flush-mounted installation, secure the flush-mounted flange in the ceiling using the mechanism provided.
  6. For surface-mounted installation, fix the mandatory safety wire for surface-mounted versions and mount the luminaire in a flush-mounted flange or a surface-mounted housing.
  7. Pay attention to the factory markings on the luminaire and wire colors when connecting.
  8. Maintain the luminaire by carrying out routine maintenance of the protective lampshade using cleaning agents. Do not clean with pressurized water or use caustic agents or solvents. Use a soft cloth to wipe the luminaire dry.
  9. In case of defects subject to guarantee, send or deliver the product to the manufacturer’s address for repair.
  10. The light source used in this luminaire should only be replaced by the manufacturer or its service representative, or a similarly qualified person.
    Note: Due to constant product development, the manufacturer reserves the right to introduce design changes in luminaires and update luminaire parameters.

IMPORTANT
Installation of the luminaire should be carried out by a duly authorised person.

SAFETY INSTRUCTIONS
Before proceeding to any work on the luminaire, always switch off the supply voltage first!

INTENDED USE

MEDILED 2.0 luminaires are designed to illuminate interiors of health care facilities featuring increased hygienic requirements; the luminaire is provided with additional frames so that it can be installed in ARMSTRONG Q-CLIP F ceiling systems.

LUMINAIRE INSTALLATION PROCEDURE

MEDILED 2.0 K (coffer)

  • When installing luminaires in a coffered ceiling, always make sure to check the load bearing capacity of the ceiling and the weight of the luminaires to be installed. To relieve the strain on the ceiling, it is recommended to fix the MEDILED 2.0 luminaires on 2 to 4 wires (not included) to a solid ceiling or a permanent construction.

  • Installation details for flush-mounted and surface-mounted

  • Figure 1 Securing the flush-mounted flange in the ceiling

  • Figure 2 Securing the base luminaire in a frame before installing in a flush-mounted flange or a surface-mounted housing.

  • Figure 3 Fixing the mandatory safety wire for surface-mounted versions

  • Figure 4 Mounting of luminaire in a flushmounted flange or a surface-mounted housing

MEDILED 2.0 – PT (flush-mounted)

  • ECO flush-mounted option

  • NEO flush-mounted option

MEDILED 2.0 – NT (surface-mounted, pendant)

CONNECTION DIAGRAMS

When installing, pay attention to the factory markings on the luminaire and wire colours

MAINTENANCE

To ensure optimum luminous flux, carry out routine maintenance of the protective lampshade. Use cleaning agents for this purpose. Do not clean with pressurised water. Do not use caustic agents or solvents. Use a soft cloth to wipe the luminaire dry.

PRODUCT GUARANTEE

  1. The following product of MILOO-ELECTRONICS Sp. z o. o. was designed and manufactured as per the applicable standards. To ensure proper functioning and user safety, the product is subject to quality control procedures during the production process. MILOO-ELECTRONICS Sp. z o. o. grants a guarantee of proper quality and functioning of the luminaire.
  2. The guarantee does not include liability for consequential damage caused to third party property.
  3. The guarantee service involves repair or replacement of defective parts at manufacturer’s discretion.
  4. The guarantee will not cover damage to parts subject to wear and tear, damage and malfunctions caused by improper operation or maintenance.
  5. During the guarantee period, the manufacturer will correct any deficiencies caused by defects in material or workmanship.
  6. The guarantee is valid only if the luminaire (complete rather than disassembled into parts), a brief description of the defect, receipt, bill of sale (with the date of purchase and stamp of the store) or a copy of the purchase invoice is sent or delivered to MILOO-ELECTRONICS Sp. z o. o. location.
    For general guarantee terms and conditions visit: https://www.emiloo.pl/en/files

REPAIR SERVICE

  • In case of defects subject to guarantee, please send or deliver the product to the address of our company.
  • Any repairs of defects outside the scope of product guarantee as well as post-guarantee repairs are carried out by our in-house service team. Please send or deliver the luminaire to the manufacturer’s address for visual inspection and cost estimate.
  • The light source used in this luminaire should only be replaced by the manufacturer or its service representative, or a similarly qualified person.
  • Given the constant product development we reserve the right to introduce design changes in luminaires and update luminaire parameters.

ABOUT COMPANY

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

MILOO User Manuals

Related Manuals