Laserliner 815666 ArcoMaster 40 Digital Goniometer Instruction Manual
- June 5, 2024
- Laserliner
Table of Contents
Laserliner 815666 ArcoMaster 40 Digital Goniometer
Read the operating instructions and the enclosed brochure „Guarantee and additional notices“ completely. Follow the instructions they contain. This document must be kept in a safe place and passed on together with the device.
Digital electronic angle gauge with inside or outside angle display from 0° to 220°. The folding measuring arm can be pulled out on either side and can also be extended. Additional vertical and horizontal vial and two illuminated flip displays that can be rotated 180°.
PRODUCT DESCRIPTION
Keypad
-
ON/OFF-Activates the 180° flip display
-
Angle bisector
-
Hold measured value
-
Set reference angle
Display -
Battery indicator: empty
-
Symbol for REF mode
-
Value of measured angle
-
HOLD indicator
ArcoMaster 40/60 -
Suspension eye
-
Vertical vial
-
Horizontal vial
-
Folding measuring arm can be pulled out on either side
-
Lay edge
-
Base / measuring surface
-
Pivot joint
Rear -
Battery compartment
-
LCD on both sides
Inserting batteries:
Open the battery compartment (16) on the rear of the device and insert two new
batteries (AA/LR6) as per the installation symbols. Correct polarity must be
observed.
- As soon as the battery symbol (5) lights up, replace the batteries.
Switching on and measuring:
The ArcoMaster can measure angles continuously from 0° to 220°.
-
Press button (1) to switch the device on.
-
All display symbols appear for a couple of seconds.
-
Place the measuring arm at the required position; the value of the measured angle (opening angle between the base arm and the folding measuring arm) appears on the display (7).
-
The measured value can be read from both displays.
NOTE: The barely audible noise emitted by the pivot joint is due to a precise sensor and is part of the design.
Holding an angle (HOLD) -
Button (3) can be used to hold the measurement results; once
they have been transmitted, pressing button (3) again will reset them.
Flip display can be rotated 180° -
If angles are to be measured overhead, press button (1) briefly and repeatedly to rotate the display by 180°.
Changing the reference angle: -
Angular differences can be transmitted using button (4): Set the required angle and press button (4). The display then changes to “0.0” and (S) also appears. The required reference angle is now set and can be transmitted to other objects. This function can also be used to measure an angular difference.
IMPORTANT: Once all angles have been transmitted, the new reference angle must be cleared; to do this, press the REF button repeatedly. Switching the device off/on will also delete the REF value.
Function of the spirit levels: -
The vertical and horizontal vials (10, 11) indicate the alignment to the measuring surface (14).
Switching off / auto shut off: -
To switch the device off, press button (1) and hold it down for at least 3 seconds. The device will switch off automatically if left in an idle state.
Technical data:
Technical data:
Vial precision| ± 0.25 mm / m
Accuracy| ± 0.2°
Measurement range:| 0 – 220°
AutoShut Off| 3 min
Arm length 40 / 60| 40 / 60 cm
Power supply| 2 x 1.5V batteries (AA/LR06)
Dimensions 40| 420 x 57 x 40 mm (W x H x D)
Dimensions 60| 600 x 57 x 40 mm (W x H x D)
Weight 40| 0.8 kg
Weight 60| 1.05 kg
Technical revisions reserved 01.17
EU directives and disposal
This device complies with all necessary standards for the free movement of
goods within the EU.
This product is an electric device and must be collected separately for
disposal according to the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
www.laserliner.com/info
SERVICE
Umarex GmbH & Co. KG
– Laserliner –
Möhnestraße 149, 59755 Arnsberg, Germany Tel.: +49 2932 638-300, Fax: +49 2932
638-333 laserliner@umarex.de
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>