MEAN WELL RSD-100D Series 100W Railway Single Output DC-DC Converter Owner’s Manual
- June 13, 2024
- MEAN WELL
Table of Contents
RSD-100D Series 100W Railway
Single Output DC-DC Converter
Owner’s Manual
100W Railway Single
Output DC-DC Converter
RSD-100 series
Features :
- Compliance to BS EN/EN50155 and BS EN/EN45545-2 railway standard
- 2:1 wide input range
- Protections: Short circuit / Overload / Over voltage /Input reverse polarity
- 4000VDC I/O isolation
- Cooling by free air convection
- Half encapsulated
- Built-in constant current limiting circuit
- 1U low profile 36mm
- All using 105°C long life electrolytic capacitors
- LED indicator for power on
- 100% full load burn-in test
- 3 years warranty
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
SPECIFICATION
MODEL| RSD•100B-5| RSD•100B•12| RSD•100B-24| RSD•100C•5| RSD-100C-12| RSD-
100C•24| RSD•100D•5| RSD•100D•12| RSD•100D•24
---|---|---|---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 5V| 12V| 24V| 5V| 12V| 24V| 5V| 12V| 24V
RATED CURRENT| 20A| 8.4A| 4.2A| 20A| 8.4A| 4.2A| 20A| 8.4A| 4.2A
CURRENT RANGE| 0 – 20A| 0 – 8.4A| 0 – 4.2A| 0 – 20A| 0 – 8.4A| 0 – 4.2A| 0 –
20A| 0 – 8.4A| 0 – 4.2A
RATED POWER| 100W| 100.8W| 100.8W| 100W| 100.8W| 100.8W| 100W| 100.8W| 100.8W
RIPPLE & NOISE (max.) Note/| 100mVp-p| 120mVp-p| 150mVp-p| 100mVp-p| 120mVp-p|
150mVp-p| 100mVp-p| 120mVp-p| 150mVp-p
VOLTAGE TOLERANCE Note.3| ±2.0%| ±2.0%| ±2.0%| ±2.0%| ±2.0%| ±2.0%| ±2.0%|
±2.0%| ±2.0%
LINE REGULATION| ±0.5%| ±0.3%| ±0.2%| ±0.5%| ±0.3%| ±0.2%| ±0.5%| ±0.2%| ±0.2%
LOAD REGULATION| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
SETUP, RISE TIME| 800ms, 50ms at full load
HOLD UP TIME (Typ.)| Please refer o page 3 Hold up Time( Load de-rating curve
)
INPUT| VOLTAGE RANGE| CONTINUOUS| 16.8 – 31.2VDC| 33.6 – 62.4VDC| 67.2 –
143VDC
1 SEC.| 14.4 – 33.6VDC| 28.8 – 67.2VDC| 57.6 – 154VDC
EFFICIENCY (Typ.)| 88%| 89%| 89%| 89%| 91%| 91%| 89.5% 91%| 90%
DC CURRENT (Typ.)| 4.8N24V| 4.8/V24V| 4.8N24V| 2.4N48V| 2.4A/48V| 2.4N48V|
1.2A/110V| 1 1.2A/110V| 1.2N110V
INRUSH CURRENT (Typ.)| 30A/24VDC| 30A/48VDC| 30A/110VDC
INTERRUPTION OF VOLTAGE SUPPLY| EN50155:2007-BIC- type comply with S1 level §
full load, comply with S2 level § 70% load ; 0-type comply with 52 level @full
load
EN50155:2017-Comply with S1 level
PROTECTION| OVERLOAD| 105 -135% rated output power
Protection type : Constant current limiting, recovers automatically after
fault condition Is removed
OVER VOLTAGE| 5.75 – TV| 1 13.8 – 16.2V1| 27.6 – 32.4V15.75| – 7V| 1 13.8 –
16.2 VI 27.6 – 32.4V1| 5.75 – 7V| 1 13.8 – 16.2V1| 27.6 – 32.4V
Protection type : Shut down ofp voltage, re-power on to recover
ENVIRONMENT| WORKING TEMP.| -40 – +55t (no derating) ; +70°C § 60% load by
free air convection ; +70t no derating with external base plate, TX class
compliance
WORKING HUMIDITY| 5 – 95% RH non-condensing
STORAGE TEMP.| -40 – +85t
TEMP. COEFFICIENT| ±0.03%/’C (0 – 50’C )
VIBRATION| 10 – 500Hz, 5G 10minitcycle, 60min. each along X, Y, Z axes ;
Mounting : compliance to IEC61373
OPERATING ALTITUDE| 5000 meters
SAFETY &
EMC (Note 5)| SAFETY STANDARDS| IEC 62368-1. UL 62368-1. AS/NZS 62368-1, EAC
TP TC 004 approved. Design refer to BS EN/EN62368-1
WITHSTAND VOLTAGE| 11P-0/13:4KVDC I/P-FG:2.5KVDC O!P-FG:2.5KVDC
ISOLATION RESISTANCE| UP-0/P, I/P-FG, O/P-FG:100M Ohms! 500VDC I25-C/ 70% RH
EMC EMISSION| Compliance to BS EWEN55032 (CISPR32) Conduction Emission: Class
A, Radiation Emission: Class 6, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2.3,4,5,6,8, BS EN/EN55035. light
industry level, EAC TP TC 020
RAILWAY STANDARD| BS EWEN50155 / IEC60571 including IEC61373 for shock &
vibration, BS ENIEN50121-3-2 for EMC ; BS EWEN45545-2 for fire protection
OTHERS| MTBF| 2446.2K hrs min. Telcordia SR-332 (Bell core) :254.2K hrs min.
MIL-HDBK-217F (25C)
DIMENSION| 161’68’36mm (12W1-1)
PACKING| 0.563Kg; 24pcs/14.5Kg10.91CUFT
NOTE| 1.All parameters NOT special y mentioned are measured at 24.48.110VDC
input, rated load and 25t: of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted
pair-wire terminated with a 0.1 uf & 47u1 parallel capacitor.
3.Tolerance : includes set up tolerance, line regulation and load regulation.
4.Strongly recommended that external output capacitance should not exceed
5000uF. (Only for: RSD-100-5 / -12)
5.The power supply is considered a component which will be installed into a
final equipment All the EMC tests are been executed by mounting the unit on a
360mm360mm metal plate with 1mm of thickness. The final equipment must be re-
confirmed that it sill meets EMC directives. For guidance on how to perform
these EMC tests. please refer to “EMI testing of component power supplies: (as
available on http://www.meanwell.com)
6.The ambient temperature derating of 3.5C/1000m with finless models and of
5C/1000m with fan models for operating altitude higher than 2000m(650040.
,I)., Product Liability Disclaimer : For detailed information. please refer to
https://wm.meanwell.corNserviceDisclaimecaspx
Mechanical Specification
Block Diagram
Input Fuse
There is one fuse connected in series to the positive input line, which is
used to protect against abnormal surge. Fuse specifications of each model are
shown as below.
Type | Fuse Type | Reference and Rating |
---|---|---|
B | Time-Lag | Conquer UDA-A, 10A, 250V |
C | Time-Lag | Conquer UDA-A, 5A, 250V |
D | Time-Lag | Conquer UDA-A, 3.15A, 250V |
Input Reverse Polarity Protection
There is a MOSFET connected in series to the negative input line. If the input
polarity is connected reversely, the MOSFET opens and there will be no output
to protect the unit.
Input Range and Transient Ability
The series has a wide range input capability. Within 30% of rated input
voltage, it can be executed at full-load operation and operate properly; with±
40% of rated input voltage, it can withstand that for 1 second.
Input Under-Voltage Protection
If input voltage drops below Vipin, the internal control IC shuts down and
there is no output voltage. It recovers automatically when input voltage
reaches above Vipin, please refer to the curve below.
Inrush Current
Inrush current is suppressed by a resistor during the initial start-up, and
then the resistor is bypassed by a MOSFET to reduce power consumption after
accomplishing the start-up.
Hold-up Time
EN50155: 2007 version –
D type is in compliance with S2 level, while B and C types are in compliance
with S1 level at full load output condition. To fulfil the requirements of S2
level, B and C types require de-rating their output load to 70%, please refer
to the curve diagrams below.
EN50155: 2017 version – Comply with S1 level
Output Voltage Adjustment
This function is optional, which the standard product does not have it. If you
do need the function, please contact MW for details.
Efficiency vs Load & Vin Curve
The efficiency vs load & Vin curves of each model are shown as below.
Parallel and Series Connection
A. Operation in Parallel
Since RSD-100 series don’t have built-in parallel circuit, it can only use
external circuits to achieve the redundant operation but not increase the
current rating.
- Add a diode at the positive-output of each power supply (as shown as below), the current rating of the diode should be larger than the maximum output current rating and attached to a suitable heat sink. This is only for redundant use (increase the reliability of the system) and users have to check suitability of the circuit by themselves.
- When using S.P.S. in parallel connection, the leakage current will increase at the same time. This could pose as a shock hazard for the user. So please contact the
supplier if you have this kind of application.
B. Operation in Series
RSD-100 can be operated in series. Here are the methods of doing it:
- Positive and negative terminals are connected as shown as below. According to the connection, you can get the positive and negative output voltages for your loads.
- Increase the output voltage (current does not change). Because RSD-100 series have no reverse blocking diode in the unit, you should add an external blocking diode to prevent the damage of every unit while starting up. The voltage rating of the external diode should be larger than V1+V2 (as shown as below).
Overload Protection
If the output draw up to 105~135% of its output power rating, the converter will go into overload protection which is constant current mode. After the faulty condition is removed, it will recover automatically. Please refer to the diagram below for the detail operation characteristic. Please note that it’s not suitable to operate within the overload region continuously, or it may cause to over temperature and reduce the life of the power supply unit or even damage it.
Over Voltage Protection
The converter shuts off to protect itself when the output voltage drawn
exceeds 115~140% of its output rating. It must be repowered on to recover.
LED Indicator
Equipped with a built-in LED indicator, the converter provides an easy way for
users to check its condition through the LED indicator.
Green : normal operation; No signal: no power or failure.
Derating Curve
a. Single unit operation
If the unit has no iron plate mounted on its bottom, the maximum ambient
temperature for the unit will be 55 as operating under full load condition. It
requires℃ de-rating output current when ambient temperature is between 55-70 ℃
, please refer to the de-rating curve as below.
Suitable installation methods are shown as below. Since RSD-100 is a semi- potted model, its thermal performances for the following installation methods are similar and share the same derating curve.
b. Operate with additional iron plate
If it is necessary to fulfil the requirements of EN50155 TX level that operate
the unit fully-loaded at 70℃ , RSD-100 series must be installed onto an iron
plate on the bottom. The size of the suggested iron plate is shown as below.
In order for optimal thermal performance, the iron plate must have an even &
smooth surface and RSD-100 series must be firmly mounted at the center of the
iron plate. Suitable installation methods are shown as below. Since RSD-100 is
a semi-potted model, its thermal performances for the following installation
methods are similar and share the same derating curve.
Immunity to Environmental Conditions
Test method | Standard | Test conditions | Status |
---|---|---|---|
Cooling Test | EN 50155 section 12.2.3 (Column 2, Class TX) EN 60068-2-1 | ||
Temperature: -40`C Dwell Time: 2 hrs/cycle | No damage | ||
Dry Heat Test | EN 50155 section 12.2.4 (Column 2, Class TX) |
EN 50155 section 12.2.4 (Column 3, Class TX & Column 4, Class TX) EN
60068-2-2| Temperature: 70°C 1 zest Duration: 6 hrs! 10min| PASS
Damp Heat Test, Cyclic| EN 50155 section 12.2.5 EN 60068-2-30| Temperature:
25°C-55°C Humidity: 90%-100% RH Duration: 48 hrs| PASS
Vibration Test| EN 50155 section 12.2.11 EN 61373| Temperature: 19°C Humidity:
65%
Duration: 10 mins| PASS
Increased Vibration Test| EN 50155 section 12.2.11 EN 61373| Temperature: 19 C
Humidity: 65% Duration: 5 hrs| PASS
Shock Test| EN 50155 section 12.2.11 EN 61373| Temperature: 21 ± St Humidity:
65 ± 5% Duration: 30ms’18| PASS
Low Temperature Storage Test| EN 50155 section 12.2.3 (Column 2, Class TX) EN
60068-2-1| Temperature: -40`C Dwell Time: 16 hrs| PASS
Salt Mist Test| EN 50155 section 12.2.10 (Class ST4)| Temperature: 35°C ±2t
Duration: 96 hrs| PASS
EN45545-2 Fire Test Conditions
Test Items | Hazard Level |
---|---|
Items | Standard |
R22 | Oxygen index test |
Smoke density test | EN 45545-2:2013 EN ISO 5659-2:2006 |
Smoke toxicity test | EN 45545-2:2013 |
NF X70-100:2006 | PASS |
R24 | Oxygen index test |
R25 | Glow-wire test |
R26 | Vertical flame test |
https://www.meanwell.com/Upload/PDF/DC-DC_EN.pdf