Laserliner 082.027A ClimaData Stick Digital Hygrometer Instructions
- June 5, 2024
- Laserliner
Table of Contents
- Laserliner 082.027A ClimaData Stick Digital Hygrometer
- Function / Application
- General safety instructions
- Safety instructions
- Information on maintenance and care
- OVERVIEW
- Inserting battery
- Software installation / Commissioning
- User interface
- Setup menu – long-term measurement
- Setup menu – real time measurement
- Notes on the measurement process and on use 6 Long-term measurement
- Measurement analysis
- Technical data
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Laserliner 082.027A ClimaData Stick Digital Hygrometer
Completely read through the operating instructions, the „Warranty and Additional Information“ booklet as well as the latest information under the internet link at the end of these instructions. Follow the instructions they contain. This document must be kept in a safe place and passed on together with the device.
Function / Application
This measuring device is used for long-term and real time measurement of ambient temperature and humidity. Measurements are stored internally and can be accessed by connecting the device to a PC via USB. Using the supplied software on a PC, the measurement parameters can be configured, a new measurement prepared, and the data subsequently analysed.
General safety instructions
- The device must only be used in accordance with its intended purpose and within the scope of the specifications.
- The structure of the device must not be modified in any way.
- Do not expose the device to mechanical stress, extreme temperatures or significant vibration.
Safety instructions
Dealing with electromagnetic radiation
- The measuring device complies with electromagnetic compatibility regulations and limit values in accordance with EMC-Directive 2014/30/EU.
- Local operating restrictions – for example, in hospitals, aircraft, petrol stations or in the vicinity of people with pacemakers – may apply. Electronic devices can potentially cause hazards or interference or be subject to hazards or interference.
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents, scouring agents and solvents. Store the device in a clean and dry place.
OVERVIEW
- Sensor
- Measurement active
- Alarm function
- Battery compartment
- Start measurement recording
- USB interface
- Protective cap
- Wall bracket
Inserting battery
Open the battery compartment and insert battery according to the symbols. Be sure to pay attention to polarity. With measurement recording activated,no LED flashing or LED (2) flashing red every 60 seconds indicates the battery charge is low.
Software installation / Commissioning
Load the CD in the drive and follow the installation routine. Close the installation program once installation has been successfully completed.
Now plug the device in a free USB port on your computer and start the application.
The software is only available in English.
User interface
Setup menu – long-term measurement
Measurement-specific settings on the connected device can be defined in the Setup menu.
New configuration automatically deletes all existing data.
-
Current time
Current time“ shows the date and time of your computer -
Start mode
Measurement can be started manually or directly.-
Manual:
Measurement is started by briefly pressing button (5). LED (2) double-flashing indicates that measurement has not yet started. -
Direct:
Measurement starts after the settings have been saved. LED (2) flashes green every 10 seconds.
-
-
Sampling rate
The sampling rate defines how often measurements are recorded. Setting options: 2 … 30 seconds, 1 / 5 / 15 / 30 minutes and 1 / 5 / 12 / 24 hours. „Max. points“ shows the maximum number of measurements. The maximum measurement duration is calculated under „Recording time”. The measurement memory is full at the end of this time. -
LED cycle setting
LED (2) indicates that recording is active. The LED signal can be set to appear every 5, 10, 15, 20, 25 or 30 seconds. -
Einstellungen Alarmfunktion
- The alarm range can be freely defined for the two measured variables temperature and relative humidity. If the measuredvalue goes above or below the set cap or floor, the alarm LED (3) flashes every 10 seconds.
- Temperature below set value: LED (3) flashes yellow
- Temperature above set value: LED (3) double-flashes yellow
- Humidity below set value: LED (3) flashes red
- Humidity above set value: LED (3) double-flashes red
-
Unit of temperature
Measured values can be shown in °C or °F.
Setup menu – real time measurement
Measurement-specific settings on the connected device can be defined in the Setup menu.
New configuration automatically deletes all existing data.
Notes on the measurement process and on use 6 Long-term measurement
- Connect ClimaData Stick to the PC
- Download and backup any existing data. Starting or configuring a new measurement deletes all existing data.
- Configure recording in the Setup menu (see section 4) and save the settings
- Depending on your start parameter, position the device at the measuring point and record measurements. Briefly press button 5 for „manual start“.
- The end of recording is reached when the memory is full or the recording is stopped by connecting and reading out the device.
- Connect ClimaData Stick to the PC, download and backup data.
Real time measurement
- Connect ClimaData Stick to the PC
- Download and backup any existing data. Starting or configuring a new measurement deletes all existing data.
- Configure recording in the Setup menu (see section 5).
- Recording starts when the settings are saved.
- The data can be saved at the end of recording.
Position the device upright to ensure sufficient air circulation around the sensor. Use the supplied wall bracket.
If the device has been placed in a cold and/or very humid environment, condensation may form in the sensor housing when it is removed due to the change in climate. Position the device upright for a while to allow it to acclimatise.
Measurement analysis
The recorded measured values are shown in a list and on a bar graph.
Long-term measurement
Real time measurement
Zoom
You can zoom in and out of partial areas. Place the mouse pointer on the bar
graph and scroll. Use the horizontal scroll bar to display further
measurements.
Context menu
The bar graph can be copied, saved as an image, printed and zoomed in the
context menu.
Technical data
EU directives and disposal
This device complies with all necessary standards for the free movement of
goods within the EU.
This product is an electric device and must be collected separately for
disposal according to the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=clidasti
SERVICE
Umarex GmbH & Co. KG
– Laserliner –Möhnestraße 149, 59755 Arnsberg, Germany Tel.: +49 2932
638-300, Fax: +49 2932 638-333 info@laserliner.com
Umarex GmbH & Co. KG Donnerfeld 2
59757 Arnsberg, Germany Tel.: +49 2932 638-300, Fax: -333
www.laserliner.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>