ONFORU CTB24 LED Light Instruction Manual

June 5, 2024
ONFORU

CTB24 LED Light
Instruction Manual

ONFORU CTB24 LED Light LED LIGHT
Product Manual
Model:
CTB72/CTB24
CTB96/CTB48

ONFORU CTB24 LED Light - fig1

**** SAFETY INFORMATION

Disconnect the power supply before attempting any work on the unit!

  • Installing these units involves work on the mains voltage supply; installation must therefore be carried out professionally in accordance with the appliance national wiring regulations and electrical operating conditions.

  • The product must be installed by a licensed professional electrician.

  • Check all components for damage, do not use the product if it is damaged.

  • To ensure the product can work normally, please use it in the voltage within the range on the lamp label.

  • The floodlight enclosure heats up when the light is on. Please adjust the angle of the light after the power off for 10-15 minutes. Do not look into the LED light at a short range or for any prolonged period(>5 min).

  • Do not install the unit on (normally) flammable surfaces.

  • Do not alter or change parts of the light at will, in case of the accidents such as breakage,  fall, electric shock, fire, etc.

  • To reduce the risk of strangulation the flexible wiring connected to this luminaire shall be effectively fixed to the wall if the wiring is within arm’s reach

  • Please use tools to adjust the lights.

  • The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced.

  • This light is a non-dimmable product. To avoid failure, please don’t connect it with the dimming controller.

  • Never plug the light in with wet hands in case of electric shock.

  • The light is IP66 waterproof, but the plug is non-waterproof. Please connect the plug indoors or connect to a socket that provides IP65 protection.

  • For type Z attachments :
    The external flexible cable or cord of this luminaire cannot be replaced; if the cord is damaged, the luminaire shall be destroyed.

  • Do not connect this light fixture to an ungrounded electrical system.
    WARNING: Installing this light in an ungrounded electrical system may cause the metal parts of the light to carry current if any wires or wire connections are damaged or loose. In this case, anyone who touches the light will receive an electric shock, resulting in injury or death.

  • Be sure to use wire nuts/connectors rated for the correct gauge and number of wires used.
    NOTE: Make sure there are no exposed wire bundles outside the wire nut/connector (if applicable).

  • Be careful not to damage or cut the wire insulation (covering) during installation. Do not let the wires touch any sharp edges.

PARAMETER

ONFORU CTB24 LED Light - fig2

| A- 430x66x76 mm / 16.93×2.58×2.99 in
B- 430x80x79 mm / 16.93×3.15×3.11 in
C- 430x110x110 mm / 16.93×4.33×4.33 in
D- 430x140x110 mm / 16.93×5.5×4.33 in
---|---
| A- 0.53 kg / 1.17Ib
B- 0.90 kg / 1.98Ib
C- 1.16 kg / 2.56Ib
D- 1.65 kg / 3.64Ib
**| 100-120V ~60Hz 220-240V ~50Hz
| Daylight White 6500K
| IP66
PF**| >0.9
| -25°C – 40°C/-4°F-104°F

Max Projected Area
A: 0.0255m² B: 0.0309m² C: 0.0425m² D: 0.0542m²
Max. Lighting Coverage
A: 40m² B: 80m² C: 115m² D: 155m²

COMPONENTS AND STRUCTURE

ONFORU CTB24 LED Light - fig3ONFORU CTB24 LED
Light - fig4

  1. Tempered Glass Lid
  2. LED Light Source
  3. Lamp Bracket
  4. Screws For Mounty
  5. Plastic Expansion Nails
  6. Screws
  7. Lamp Brackets
  8. Hex Screw Key

NOTE

ONFORU CTB24 LED Light - fig5

  1. – Make sure that the distance between the light and the object being lit is more than 1 meter, so as to avoid high temperature caused by a short distance.
  2. – Earth wire is required for connection for electric safety.
  3. – Lights that are not suitable for covering with thermal insulation materials.

Limitations of Indoor and Outdoor Use

  1. This light is waterproof and dustproof. It is protected against rain, but it cannot be immersed in water.
  2. The mounting position of this light should be able to bear at least 10 times as heavy as the light.
  3. This light is powered by a High Voltage Alternating Current (HVAC). It should be connected to the ground wire and kept away from easy reach.
  4. This light should be used in conditions with sound heat dissipation. The working temperature of it should be less than 40°C. Overhigh working temperature will cause serious lumen depression and affect the lifespan of the light.

INSTALLATION STEPS

ONFORU CTB24 LED Light - fig6

Step 1: Fix the bracket on the lamp with the combination screw. (as shown in the image)
Step 2: According to the spacing (see the “A” part of the picture) of four holes on the lamp brackets, drill four mounting holes. (as shown in the image)
Step 3: Put the brackets onto the prepared mounting holes and then screw them on.
Step 4: Adjust the beam direction as you like, and then plug it into the main socket.

OPERATION & MAINTENANCE

  • Prior to cleaning the light, make sure it has been disconnected from the power supply.
  • The unit is not suitable for burglar alarm systems as it is not tamperproof in the manner prescribed for such systems.
  • Never use any chemicals or corrosive substances for cleaning.

DISPOSAL

Electrical and electronic equipment, accessories and packaging must be recycled in an environmentally compatible manner.
Do not dispose of electrical and electronic equipment as domestic waste.
EU countries only:
Under the current European Directive on Waste Electrical and Electronic equipment and its implementation in national law, electrical and electronic equipment no longer suitable for use must be collected separately and recycled in an environmentally compatible manner.

Manufacturer / Hersteller:
Shen Zhen Shi Meng Zhi Tuo Ke Ji You Xian Gong Si
Address: qian wan yi lu 1 hao A dong 201 shi qian hai shen gang he zuo qu Shen Zhen, Guang  Dong, 518000, CN
[email protected] www.onforuleds.com

ONFORU CTB24 LED Light - icon7 MDH LIGHTING LTD
Suite 302, 292 Strovolos Avenue, 2048 Strovolos
Nicosia, Cyprus | [email protected]

ONFORU CTB24 LED Light - icon8MDH LIGHTING LTD
69 Aberdeen Avenue, Cambridge CB2 8DL,
United Kingdom | [email protected]

Made in China

Documents / Resources