ONFORU C15UVW UV LED Flood Light Instruction Manual

June 5, 2024
ONFORU

C15UVW UV LED Flood Light
Instruction Manual
ONFONFORU C15UVW UV LED Flood Light - icon 1ORU C15UVW UV LED Flood
Light

MODEL:
C15UuVw C30UuVw Cc6ouvw c100uvw

UV LED FLOOD LIGHT
Product Manual
UK 220-240V AC
ONFORU C15UVW UV LED Flood Light - fig

SAFETY INFORMATION

**** Disconnect the power supply before attempting any work on the unit!

  • Installing these units involves work on the mains voltage supply; installation must therefore be carried out professionally in accordance with the appliance national wiring regulations and electrical operating conditions.
  • Never plug the light in with wet hands in case of electric shock.
  • Check all components for damage, do not use the product if it is damaged.
  • To ensure the product can work normally, please use it in the voltage within the range on the lamp label.
  • Do not install the unit on (normally) flammable surfaces.
  • The floodlight enclosure heats up when the light is on. Only adjust the angle of the LED panel once it has cooled down. Do not look into the LED light at a short range or for any prolonged period(>5 min).
  • Do not alter or change parts of the light at will, in case of the accidents such as breakage, fall, electric shock, fire, etc.
  • The light is IP66 waterproof, but the plug is non-waterproof. Please connect the plug indoors or connect to a socket that provides IP65 protection.
  • This is a UV lamp. Human eyes can only detect a small part of the light, so it will appear a little dim when it lights up. Since it is mainly used for reaction and other purposes. If you just want to buy a violet light, this UV lamp is not recommended for you.

PARAMETER

ONFORU C15UVW UV LED Flood Light - fig 1

| A. 140x32x90 mm 5.51×1.26×3.54in
B.166x36x116mm 6.54×1.42×4.57in
C.240×41.5x160mm 9.45×1.63×6.3in
D.300×46.5x200mm 11.81×1.83×7.87in
---|---
| 100-120V AC 60Hz 220-240V AC 50Hz
| 385-400nm, UVA Level
| IP66
| -25°C – 40°C

**COMPONENTS AND STRUCTURE

ONFORU C15UVW UV LED Flood Light - fig 2**

  1. Tempered Glass Lid
  2. LED Light Source
  3. Lamp Bracket

Note: Cord – type Y attachment.
For type Y attachment: If the external flexible cable or cord of this luminaire is damaged, it is exclusively replaced by the manufacturer or his service agent or a similarly qualified person in order to avoid a hazard.
Instructions for the remote control

ON/OFF Turn on/off
UV UV light
WHITE White light
B+/B- Brightness adjustment, ten levels
S+/S- Speed adjustment, ten levels
FLASH Flash mode
STROBE Strobe mode
2H/4H/8H Timing

ONFORU C15UVW UV LED Flood Light - fig 3

NOTE
ONFORU C15UVW UV LED Flood Light - fig 4

  1. Make sure that the distance between the light and the object being lit is more than 1 meter, so as to avoid high temperature caused by short distance.
  2. Caution, risk of electric shock.
  3. Earth wire is required for connection for electric safety.

Non-User Replaceable Light Source
The light source contained in this flood light shall only be replaced by the manufacturer or his service agent or a similar qualified person.
Limitations of Indoor and Outdoor Use

  1. This light is waterproof and dustproof. It is protected against rain, but it cannot be immersed in water.
  2.  The mounting position of this light should be able to bear at least 10 times as heavy as the light.
  3. This light should be used in conditions with sound heat dissipation. The working temperature of it should be less than 45°C. Overhigh working temperature will cause serious lumen depression and affect the lifespan of the light.

INSTALLATION STEPS

ONFORU C15UVW UV LED Flood Light - fig 5

Step 1 : According to the spacing (see the “A” part of the picture) of two screw bits on the LED Light bracket, drill two mounting holes.
Step 2 : Put the bracket onto the prepared mounting holes and then screw it on.
Step 3 : Adjust the beam direction as you like, and then plug it into the main socket.

OPERATION & MAINTENANCE

  • Prior to cleaning the light, make sure it has been disconnected from the power supply.
  • The unit is not suitable for burglar alarm systems as it is not tamperproof in the manner prescribed for such systems.
  • Never use any chemicals or corrosive substances for cleaning.

DISPOSAL

Electrical and electronic equipment, accessories, and packaging must be recycled in an environmentally compatible manner.
Do not dispose of electrical and electronic equipment as domestic waste.
EU countries only:
Under the current European Directive on Waste Electrical and Electronic equipment and its implementation in national law, electrical and electronic equipment no longer suitable for use must be collected separately and recycled in an environmentally compatible manner.

Manufacturer / Hersteller:
Shenzhen ShiMeng ZhiTuo KeJiYou XianGongSi
Address: qianwanyilu 1hao A dong 201 shiqianhai Shenyang hezuoqu Shenzhen, Guang
Dong, 518000, CN
support@onforuled.com www.onforuleds.com

BellaCocool GmbH
Pettenkoferstraße 18, 10247, Berlin, Germany
support@onforuled.com

MDH LIGHTING LTD
UNIT G25 WATERFRONT STUDIOS 1 DOCK ROAD
LONDON UNITED KINGDOM E16 1AH
support@onforuled.com
Made in China

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals