INSTRUCTIONS FOR USE

Package Contents:
Insta-Feed™ Bottle Warmer Quick Reference Guide 2x Storage Caps
Specifications:
Nominal voltage: 120VAC/60Hz 500W

WARNING: Read the ENTIRE instruction manual to become familiar with the features of the product before operating. Failure to operate the product correctly can result in damage to the product, and personal property and cause serious injury. Failure to operate this product in a safe and responsible manner could result in injury or damage to the product or other property. This product is not intended for use by children. Do not attempt disassembly or use incompatible components. This manual contains instructions for safety, operation, and maintenance.

IMPORTANT SAFEGUARDS
READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS BEFORE USING THIS APPLIANCE. WHEN USING ELECTRICAL APPLIANCES, PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, AND INJURY TO PERSONS, INCLUDES THE FOLLOWING:

  • DO NOT IMMERSE IN WATER.
  • HOUSEHOLD USE ONLY.
  • Do not touch hot surfaces.
  • DO NOT open Sterilizing Lid or reach over the appliance while in use, as steam will cause burns and serious injuries. Do not touch the lid or interior parts during use, as serious injury may occur.
  • Always remove the Sterilizing Lid carefully by the handle. Take care when removing the Sterilizing Lid as there may be some residual steam—keep hands and face away. Allow the steam to clear before reaching into the unit. Always retrieve the sterilized parts by removing the Lift-Out Basket.
  • To protect against electrical shock, do not immerse the cord or plug in water or other liquids.
  • Close supervision is necessary when any appliance is used near children.
  • This appliance shall not be used by children. Keep the appliance and its cord out of reach of children.
  • Unplug from outlet when not in use and before cleaning. Allow cooling before putting on or taking off parts.
  • Always unplug the warmer before filling. Do not use Sterilizing Lid for warming.
  • Do not operate any appliance with a damaged cord or plug or after the appliance malfunctions or has been damaged in any manner. Return appliance to the nearest authorized service facility for examination, repair, or adjustment.
  • Misuse of the product may cause potential injury.
  • The heating element surface is subject to residual heat after use.
  • The use of accessory attachments is not recommended by Handi-Craft Company and may cause injuries.
  • Do not use outdoors.
  • Do not let the cord hang over the edge of the table or counter or touch hot surfaces.
  • Do not place on or near a hot gas or electric burner or in a heated oven.
  • Extreme caution must be used when moving an appliance containing hot liquids.
  • To operate, plug the cord into a wall outlet. To disconnect, turn any control to “off,” then remove the plug from the wall outlet.
  • Always add water and then press Power Button. If the Power Button is pressed first, steam may form when water is added.
  • Never freeze glass containers, as glass may break.
  • Do not use this warmer for frozen milk or food. Always thaw frozen milk or food overnight in the refrigerator first before warming.
  • Do not use appliances for other than intended use.
  • Never immerse the warmer or power cord in water.
  • When in use, the warmer contains hot water. Be careful to avoid spilling or splashing any water on yourself when removing contents from the warmer.
  • Before serving, be sure the food is at a safe temperature.
  • Warming food for long periods is not recommended.
  • Food should not be heated for too long
  • Before feeding, always check the content temperature of the bottle or the small jar.
  • This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit into a polarized outlet only one way. If the plug does not fit fully into the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to modify the plug in any way.
  • Before servicing, unplug the cord from the wall outlet. Do not leave the cord within the child’s reach.
  • The preheating of the appliance is not necessary.
  • A short power-supply cord is provided to reduce the risk resulting from becoming entangled in or tripping over a longer cord.
  • Do not use an extension cord.
  • Children shall not play with the appliance.
  • Any maintenance servicing should be performed by an authorized service representative.
  • NOT FOR SPACE HEATING PURPOSES.

SAVE THESE INSTRUCTIONS

PARTS OF THE INSTA-FEED™BOTTLE WARMER:

  1. Warming Chamber
  2. Indicator Light
  3. Power Button
  4. Sterilizing Lid
  5. Adapter Ring
  6. Measuring Cup
  7. Lift-Out Basket
  8. Storage Caps

WARMING BOTTLES AND FOOD JARS
CAUTION: Always unplug the warmer before filling. Do not use Sterilizing Lid for warming.

  1. Remove the Measuring Cup from the rear of the warmer.

  2. Add DISTILLED water to the Measuring Cup, following the Warming Guide on page 5 to determine the amount of water to add based on your bottle type.
    Note: These amounts are a guide only. There are many variables that can impact the final temperature of the bottle or food jar you are warming, such as starting temperature, size, and shape. Always test the temperature before feeding your baby.

  3. Pour the DISTILLED water from the Measuring Cup directly into the Warming Chamber. Do not overfill, as overfilling may cause the bottle/food jar to be overheated
    or may cause damage to the unit.
    USE DISTILLED WATER ONLY! Tap water and bottled water contain minerals that shorten the life of this appliance. Damage from the use of non-distilled water will void the warranty.

  4. Replace the Measuring Cup and plug in the power cord. Note: The first time the unit is plugged in, the warming cycle may begin automatically. If the Indicator Light is on upon plugging the unit in, wait for the warming cycle to end (Indicator Light will turn off) and allow the unit to cool down for 10 minutes before using.

  5. Place the bottle or food jar inside the Warming Chamber as outlined below.
    • Wide Neck Bottle: Place bottle directly into Warming Chamber.
    • Narrow Bottle: Place the Adapter Ring on top of the Warming Chamber, then place the bottle in Warming Chamber. The Adapter Ring will keep your bottle centered
    over the heating plate for even warming.
    Note: To prevent leakage when warming Dr. Brown’s® bottles, remove the internal parts, collar, and nipple/teat, and replace them with the included Storage Cap.
    • Food Jar: Place the food jar into the Lift-Out Basket, then place Lift-Out Basket in
    Warming Chamber.
    Note: Always remove the lid of the food jar prior to warming. After warming cycle is complete, be sure to stir food thoroughly until it is an even temperature throughout.

  6. Press the Power Button. The Indicator Light will turn on, indicating the warming cycle has begun.
    **CAUTION: Always add water and then press Power Button. If the Power Button is pressed first, steam may form when water is added.
    WARNING: DO NOT reach over the appliance while in use, as steam will cause burns and serious injuries. Do not touch hot surfaces during or immediately after use.
    Note:** If the Power Button is pressed without water added, the unit will shut off automatically after a short period. If this happens, wait at least 10 minutes to allow the warmer to cool before adding water and starting the warming cycle.

  7. When the Indicator Light turns off, the warming cycle is done. Remove the bottle/food jar promptly to avoid overheating. Gently stir or swirl content to ensure it warms evenly. DO NOT shake.
    Note: Always test the temperature before feeding your baby. Adjust the amount of water added to the warming chamber as needed; if the bottle/food jar is too cold, add slightly more water next time. If the bottle/food jar is too warm, use slightly less
    water next time.

Wait at least 10 minutes to allow the warmer to cool before using again.
WARMING GUIDE

Bottle/Jar Type Volume **Temperature*** Fill Line (mL)

| ****

Plastic

| 4 oz / 120 mL| Room Temp| 8
4 oz / 120 mL| Refrigerator| 14+2
8 oz / 250 mL| Room Temp| 8
8 oz / 250 mL| Refrigerator| 14+2


Glass

| 4 oz / 120 mL| Room Temp| 5
4 oz / 120 mL| Refrigerator| 10
8 oz / 250 mL| Room Temp| 4
8 oz / 250 mL| Refrigerator| 7



| ****

Plastic

| 5 oz / 150 mL| Room Temp| 14+4
5 oz / 150 mL| Refrigerator| 14+14+2
9 oz / 270 mL| Room Temp| 14+7
9 oz / 270 mL| Refrigerator| 14+14+14+4


Glass

| 5 oz / 150 mL| Room Temp| 8
5 oz / 150 mL| Refrigerator| 14+2
9 oz / 270 mL| Room Temp| 10
9 oz / 270 mL| Refrigerator| 14+8


| Glass| 4 oz / 120 mL| Room Temp| 14+2
*Room Temp = 72ºF/22ºC, Refrigerator = 39ºF/4ºC|
WARNING: THIS TIME CHART IS APPROXIMATE FOR DR. BROWN’S ® **BOTTLE VESSEL SIZES. WARMING TIMES WILL VARY DEPENDING ON THE BOTTLE VESSEL SHAPE AND VOLUME.
CAUTION: NEVER FREEZE GLASS CONTAINERS, AS GLASS MAY BREAK. DO NOT USE THIS WARMER FOR FROZEN MILK OR FOOD. ALWAYS THAW FROZEN MILK OR FOOD OVERNIGHT IN THE REFRIGERATOR FIRST BEFORE WARMING.**

STERILIZING SMALL PARTS

CAUTION: Always unplug the warmer before filling.
The sterilize feature can be used for any small part safe for steam sterilization. DO NOT sterilize bottles in this sterilizer.

  1. Add 2 oz / 60 mL of DISTILLED water directly into the Warming Chamber. Do not overfill, as overfilling may cause damage to the unit.

  2. Place small parts (nipples/teats, pacifiers/soothers, etc.) to be sterilized in the Lift-Out Basket.

  3. Place the Lift-Out Basket with small parts into the Warming Chamber.

  4. Place the Adapter Ring on top of the Warming Chamber.

  5. Place the Sterilizing Lid on top of the Adapter Ring.

  6. Plug in the power cord and press the Power Button. The Indicator Light will turn on, indicating the sterilizing cycle has begun.
    WARNING: DO NOT open Sterilizing Lid or reach over the appliance while in use, as steam will cause burns and serious injuries. Do not touch hot surfaces during or immediately after use.

  7. When the Indicator Light turns off, the sterilizing cycle is done.

  8. Allow the unit to cool for at least 10 minutes before removing the Sterilizing Lid, Adapter Ring, and Lift-Out Basket.
    CAUTION: Be sure to observe the 10-minute cooling time as warmer parts and sterilized parts will be hot. Always remove the Sterilizing Lid carefully by the handle. Take care when removing the Sterilizing Lid as there may be some residual steam—keep hands and face away. Allow the steam to clear before reaching into the unit. Always retrieve the sterilized parts by removing the Lift-Out Basket.

TROUBLESHOOTING TIPS

  • If the warmer is not operating, check that the power cable is connected to the power outlet and water has been added to the warming chamber.
  • If Indicator Light does not come on/the warming cycle does not start, the warmer may be cooling down. Wait 10 minutes and try again.
  • If Indicator Light comes on upon plugging in but before Power Button is pressed, it is possible the Power Button was pressed while the warmer was unplugged. Wait for the warming cycle to end (Indicator Light will turn off) and allow the unit to cool down for 10 minutes before using.
  • If bottle/food is too warm/too cold after the warming cycle, note the Warming Guide only shows the approximate amount of water needed. Warming times are impacted
    by many variables, so adjust the amount of water added as needed. If the bottle/ food jar is too cold, add slightly more water next time. If the bottle/food jar is too warm, use slightly less water next time.

CLEANING THE INSTA-FEED™ BOTTLE WARMER AND PARTS
CAUTION: ALWAYS TURN OFF, UNPLUG, AND ALLOW THE UNIT TO COOL BEFORE CLEANING.
Bottle Warmer Unit: Wipe the outer surface and inside the Warming Chamber with a damp cloth or sponge using mild liquid soap. Wipe with clean water and allow unit to
air dry. DO NOT SUBMERGE THE UNIT IN WATER.
Lift-Out Basket, Adapter Ring, Sterilizing Lid, and Measuring Cup: Dishwasher safe (top rack only) or wash with soapy water. Rinse with clean water and allow to air dry.
DE-SCALING THE INSTA-FEED™ BOTTLE WARMER
It is recommended to de-scale your Insta-Feed™ Bottle Warmer every four weeks to ensure the unit continues to work properly. To de-scale, follow the steps below.

  1. Unplug the appliance from power.

  2. Mix 2 oz / 60 mL of white vinegar with 4 oz / 120 mL of distilled water.
    DO NOT USE BLEACH.

  3. Pour the white vinegar and water mixture directly into the Warming Chamber.

  4. Allow the mixture to stand in the unit until any mineral deposits dissolve.

  5. Discard the cleaning mixture and rinse with clean water.

  6. Wipe the Warming Chamber dry with a cloth or allow it to air dry.

NOTE: DO NOT USE BLEACH, HARSH ABRASIVES, OR SOLVENTS TO CLEAN THE WARMING CHAMBER OR HEATING ELEMENTS AS THEY MAY CAUSE PERMANENT DAMAGE AND WILL VOID THE WARRANTY.

LIMITED PRODUCT WARRANTY
Dr. Brown’s Natural Flow® Insta-Feed™ Bottle Warmer includes a one-year warranty against defects in material and workmanship from the date of purchase. In the unlikely
event of a malfunction or defect during the warranty period, please contact Handi-Craft’s Customer Service. If outside of the US or Canada, please contact your local distributor. You will be required to provide proof of purchase.
This warranty does not cover a defect that has been caused by negligence, accidents, or improper use of the appliance. To keep your Insta-Feed™ Bottle Warmer in good condition and retain your warranty, USE ONLY DISTILLED WATER.

CUSTOMER SERVICE
If you experience unsatisfactory operation or have questions/comments, please call Handi-Craft’s Customer Service at 1-800-778-9001, and send an email to [email protected], or write to Handi-Craft Company, Customer Service, 4433 Fyler Avenue, St. Louis, Missouri 63116 USA. Our Customer Service Representative will advise you on how to correct the problem yourself or will ask you to return the product for repair or replacement. If outside of the US or Canada, please contact your local distributor.

FCC Compliance Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Importer: Handi-Craft Company
Address: 4433 Fyler Ave., St. Louis, MO 63116
Phone: 800-778-9001
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

|
---|---

HANDI–CRAFT COMPANY
ST. LOUIS, MISSOURI 63116 USA/EE.UU.
drbrownsbaby.com 800-778-9001
Made in China. Fabriqué en Chine.
Fabricado en China.
May be patented in the USA,
see drbrownsbaby.com/patents.
©2021 Handi-Craft Company. All Rights Reserved. DR. BROWN’S and all other trademarks are owned or used under license by Handi-Craft Company.
WSP007

Documents / Resources

| DrBrown s AC184 Insta Feed Bottle Warmer [pdf] Instruction Manual
AC184, Insta Feed Bottle Warmer, AC184 Insta Feed Bottle Warmer, Feed Bottle Warmer, Bottle Warmer, Warmer
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

DrBrown s User Manuals

Related Manuals