Completely read through the operating instructions, the “Warranty and Additional Information” booklet as well as the latest information under the internet link at the end of these instructions. Follow the instructions they contain. This document must be kept in a safe place and passed on together with the device.

Function / Application

The MaxView Camera is a camera unit for connection to the base VideoFlex unit. When combined with the base unit, color video images are sent to the LCD for inspecting highly inaccessible locations such as cavities, shafts, masonry, or vehicles.

General safety instructions

  • The device must only be used in accordance with its intended purpose and within the scope of the specifications.
  • The measuring tools and accessories are not toys. Keep out of reach of children.
  • The structure of the device must not be modified in any way.
  • Do not expose the device to mechanical stress, extreme temperatures or significant vibration.
  • The device must no longer be used if one or more of its functions fail or the battery charge is weak.
  • The camera head is not acid-resistant or fireproof.
  •  It is absolutely vital to ensure that the MaxView Camera does not come into contact with chemicals, voltage, moving or hot objects. This can damage the device and put its user at risk of serious injury.
  • The MaxView Camera must not be used for medical examinations / examining people.
  • Please ensure compliance with the safety regulations set out by local and national authorities with regard to the correct and proper use of the device.
  •  The unit is not suitable for taking measurements close to dangerous voltages. Therefore always make sure that conductive parts are at zero potential when carrying out measurements in the vicinity of electrical systems. Safe isolation from the power supply and precautions to prevent systems being switched on again must be ensured by implementing suitable measures.

Safety instructions
Using artificial, optical emission (OStrV)

LED outlet

Laserliner 082.217A MaxView Camera - LED outlet

  • The device works with LEDs of risk group RG 0 (exempt, no risk) in accordance with the latest versions of applicable standards relating to photobiological safety (EN 62471:2008-09ff / IEC/TR 62471:2006-07ff).
  • When used for the intended purpose and under reasonably foreseeable conditions, the accessible radiation of the LEDs is safe for the human eye and skin.

Safety instructions
Dealing with electromagnetic radiation

  • The measuring device complies with electromagnetic compatibility regulations and limits values in accordance with EMC-Directive 2014/30/EU.
  • Local operating restrictions – for example, in hospitals, aircraft, petrol stations, or in the vicinity of people with pacemakers – may apply. Electronic devices can potentially cause hazards or interference or be subject to hazards or interference.

Information on maintenance and care

Clean all components with a damp cloth and do not use cleaning agents, scouring agents, or solvents.
Store the device in a clean and dry place.

Laserliner 082.217A MaxView Camera - Information on maintenance and
care

  1. Base unit connection
  2. Flexible cable
  3. Camera head with 4 high-power LEDs

 Focal depth

The MaxView Camera delivers sharp images in a range between 2 and 30 cm from the camera head.

Laserliner 082.217A MaxView Camera - Focal depth

Objects well beyond the focus range may appear blurred.

Laserliner 082.217A MaxView Camera - blurred

Connection for flexible cable

Laserliner 1519100 Ultra Camera - Connection for flexible
cable

Technical data

Subject to technical alterations. 20W41

Type of camera CMOS image sensor
Camera head ø 17 mm
Camera head protection class water-resistant, IP 67
Camera head LEDs 4
Camera resolution 640 x 480 pixels
Field of vision 57°
Camera focus F2 cm – F30 cm
Cable diameter 9,5 mm
Length of flexible cable 1,5 m
Minimum bending radius 75 mm
Operating conditions 0°C … 45°C, max. humidity 20 … 90% rH,

no condensation, max. working altitude 4000 m above sea level
Storage conditions| -10°C … 60°C, max. humidity 80% rH
Weight| 298 g
Dimensions (W x H x D)| 1580 x 18 x 18 mm

EU directives and disposal
This device complies with all necessary standards for the free movement of goods within the EU.
This product is an electric device and must be collected separately for disposal according to the European Directive on waste electrical and electronic equipment.
Further safety and supplementary notices at: http://laserliner.com/info?an=AIF

MaxView Camera

Laserliner 082.217A MaxView Camera - MaxView Camera

SERVICE

Umarex GmbH & Co. KG
– Laserliner –
Möhnestraße 149, 59755 Arnsberg, Germany
Tel.: +49 2932 638-300,
Fax: +49 2932 638-333
[email protected]| Umarex GmbH & Co. KG
Donnerfeld 2
59757 Arnsberg, Germany
Tel.: +49 2932 638-300,
Fax: -333
www.laserliner.com
---|---

Rev20W41

Documents / Resources

| Laserliner 082.217A MaxView Camera [pdf] Instruction Manual
082.217A MaxView Camera, 082.217A, MaxView Camera
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Laserliner User Manuals

Related Manuals