GM Lighting 902518 ChromaDim Puck Downlight Instruction Manual

June 3, 2024
GM Lighting

INSTALLATION INSTRUCTIONS
ChromaDim™ Puck

BEFORE YOU START:

  • Please check local electrical codes before beginning
  • Turn power off before installing
  • Make sure to use proper rated wire

RECESSED INSTALLATION:

NOTE: WE RECOMMEND THAT YOU ENGAGE A QUALIFIED AND LICENSED ELECTRICIAN. ALL SYSTEM PARTS ARE COMPATIBLE WITH AND ONLY WORK TOGETHER. DO NOT ATTEMPT TO SWAP OUT OTHER MANUFACTURERS’ PRODUCTS. ENSURE THAT BOTH THE WALL SWITCH AND LED DRIVER IS GROUNDED IN ACCORDANCE WITH NEC OR LOCAL ELECTRICAL CODES.
DO NOT INSTALL IN AN APPLICATION THAT IS OUTSIDE OF THE PRODUCTS LISTED AMBIENT TEMPERATURE AND IN AN AREA THAT IS NOT EASILY ACCESSED FOR SERVICE REQUIREMENTS. MOUNT AND CONNECT CHROMADIM DRIVER AND WALL CONTROLLER PER INSTRUCTIONS THAT COME WITH THAT UNIT.

  1. Familiarize yourself with the puck mounting ring, and the puck body. You’ll need the mounting ring for surface mounting. Discard it for recessed mounting (Fig. 1)

  2. Determine the position of your puck(s) and trace a 3” diameter circle on the surface material. Using a keyhole saw or 3” hole saw, cut through the surface (Fig. 2).
    SURFACE INSTALLATION:

  3. Screw the puck mounting ring to the surface. (Fig. 3).

  4. Feed three-wire leads up into the surface hole. Connect the puck leads to the White, Red, and Green terminals in the ChromaDim driver (Fig. 4). Push the puck firmly up into the surface mount ring, allowing the springs to compress and hold the puck tightly to the surface mount ring (Fig. 5).
    RECESSED INSTALLATION:

  5. Follow the previous steps, but omit using a surface mount ring. Instead, push the ChromaDim puck body up into a hole cut out, achieving a clean recessed installation (Fig. 6).
    MULTIPLE PUCK INSTALLATION:

  6. You can install as many as 30 – 3W ChromaDim pucks on one lead. In order to do this, first lay out your run, giving ample distance between pucks, and install per directions for surface mount or recessed installation. Follow the diagram at right (Fig. 7).

©2022 GM Lighting Specifications are subject to change without notice.
18700 Ridgeland Ave.,
Tinley Park, IL 60477
Toll-Free: 866-671-0811
FAX: 708-478-2640
www.gmlighting.net
tech@gmlighting.net
ChromaDimDownLight-A_040822

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

GM Lighting User Manuals

Related Manuals