BATHOLOGY Spectrum 440 Steam White Light System User Manual

June 1, 2024
BATHOLOGY

BATHOLOGY Spectrum 440 Steam White Light System

BATHOLOGY-Spectrum-440-Steam-White-Light-System-
PRODUCT

FAQ

Frequently Asked Questions

  • Q: Can I install the Spectrum 440 system on my own?
    • A: It is recommended to have the system installed by a licensed, qualified electrician to ensure proper installation and safety compliance.
  • Q: What should I do if I encounter uninsulated electrical connections during installation?
    • A: In case of uninsulated electrical connections, use insulating gloves to protect yourself from any potential hazards.

Installation Considerations

Please read this manual in its entirely prior to installation

IMPORTANT: DO NOT HOT SWAP ANY ELECTRICAL COMPONENTS. This will void the warranty, and likely cause the product to fail.

  • CAUTION: Carefully review all installation options and instructions before proceeding.
  • CAUTION: For safety purposes, use safety goggles at all times.
  • WARNING: Do not hot swap any electrical components. This will void the warranty, and likely cause the product to fail. Fully disconnect the system from its power source before swapping any electrical components.
  • WARNING: Check for piping / electrical before cutting or drilling.
  • WARNING: Some electrical components are not waterproof.
  • WARNING: If there is any risk of uninsulated electrical connections in your wall / ceiling area, use insulating gloves.
  • WARNING: The Spectrum 440 Steam White Light System can be controlled by the use of a light switch provided by others. NEVER place a switch where it can be reached from a tub or shower.
  • IMPORTANT: All wiring must be done in accordance with National Electric Code and local building code.
  • IMPORTANT: The Spectrum 440 Steam White Light System should be installed by a licensed, qualified electrician.
  • IMPORTANT: Consider light placement carefully. The fixture(s) for this system should be placed to avoid direct contact with the bather’s eye.

Installation

Package Includes

BATHOLOGY-Spectrum-440-Steam-White-Light-System-FIG-1

Item Quantity Description
A 1 Driver
  1 Screw
1 Locknut
B 1 Enclosure
  1 Enclosure Top
  2 Enclosure Top Screws
--- --- ---
4 Screws / Anchors
4 Wire Nuts
1 Ground Connector
C 2 Strain Relief Bushings

BATHOLOGY-Spectrum-440-Steam-White-Light-System-FIG-2

Item Quantity Description
D 1 Male NEMA Cable
E 1 Light Cable
F 1 Cat6 Cable, 1’
G 1* Cat6 Cable, 25’
H 1 Output Box
--- --- ---
I 1* Mounting Template
J 1* Brilliance Light Fixture
K 1* Wire Fit Cap
  1 Silicone Sealant, 1 ounce

NOTE: Quantity with an * increases by one per each additional light purchased. Quantities shown assume no additional lights purchased with Spectrum 440 system.

IMPORTANT: DO NOT HOT SWAP ANY ELECTRICAL COMPONENTS. This will void the warranty, and likely cause the product to fail.

BATHOLOGY-Spectrum-440-Steam-White-Light-System-FIG-4

  1. Install a standard single gang electrical box in an accessible, dry location.
  2. Run a grounded 120VAC from the power supply to the accessible, dry location’s electrical box.
  3. Secure enclosure (B) to wall in an accessible, dry location using provided screws / anchors.BATHOLOGY-Spectrum-440-Steam-White-Light-System-FIG-5
  4. Determine number of lights per input. Limit 6 lights per input.
  5. Determine desired brilliance light fixture (J) location. Note: Fixture should be placed to avoid direct contact with the bather’s eyes. Allow for 2” clearance from insulation above and around the fixture.BATHOLOGY-Spectrum-440-Steam-White-Light-System-FIG-6
  6. Optional: Mount 16” location template (I) to ceiling / wall framework. Use notches to quickly align desired location to other fixtures in the room.BATHOLOGY-Spectrum-440-Steam-White-Light-System-FIG-7
  7. Make a 1-5/8” hole in desired location.
  8. For Wet environments, apply a 1/8” bead of silicone around the edge of the light as required to form a water tight seal.
  9. Mount brilliance light fixture (J) to ceiling through 1-5/8” cutout. Allow for 2” clearance from insulation above and around the fixture.
  10. Repeat steps 6 – 9 for each light.
  11. Allow silicone to cure for 24 hours before exposing product to any source of moisture.

Product Care

For routine cleaning, simply use a soft damp cloth and common household soap. Use a damp cloth to wipe clean, then dry. Clean product frequently to avoid calcium deposits on surfaces. Use only mild soap. Never use abrasive cleaners, bleach, disinfectants or cleaning products containing alcohol, ammonia, hydrochloric or phosphoric acids as they may damage the product’s finish. To clean electrical components, gently wipe down using a dry cloth or duster. Never use a wet duster, water, or any other liquid to clean the device.

Installation

BATHOLOGY-Spectrum-440-Steam-White-Light-System-FIG-8 BATHOLOGY-Spectrum-440-Steam-White-Light-System-
FIG-10

Specifications

Driver

  • Operating Voltage: 120 VAC Output
  • Voltage: 700mA
  • Power Consumption: 35W Nominal
  • Amperage: 1.1 Amps Dimensions: 5-7/8” W x 1-1/8” H x 1-5/8” D

Brilliance Fixture

  • Type: LED Cool White (5650-6300K)
  • Operating Voltage: 12VDC
  • Maximum Input Current: 700mA
  • LED: 1 x 3 Watt
  • Beam Angle: 35°Clear/120°Frosted
  • Trim Finish: Polished Stainless Steel
  • Housing Composition: Stainless Steel
  • Lens: Clear or Frosted, 1-7/32” Diameter
  • Lens Composition: Tempered Glass
  • Rough-in Cutout: 1-5/8” to 1-11/16”
  • Trim Dimension: 2-3/64” Diameter, 1/8” Profile
  • Body Dimensions: 1-15/32”
  • Diameter x 1-7/8” Deep
  • Rating: IP68
  • Certifications: CE / RoHS / WEEE
  • Max Operating Temperature: 130°F when installed per instructions

Enclosure

  • Housing Composition: Steel, black powder coated finish
  • Dimensions: 7-3/4” W x 1-7/8” H x 4-7/8” D
  • Standards: NEMA 1
  • Listing: ETL, UL

Construction Template

  • Composition: Steel, Galvanized, Gauge 22
  • Dimensions: 15-1/8” L x 1/32” H x 3” D

Replacement Parts

Description Part Number
Driver Spectrum078
Enclosure Spectrum079
Strain Relief Bushings Spectrum077
Male NEMA Cable Spectrum038
Cat6 Cable, 1’ 210-BP031128
Cat6 Cable, 25’ 210-BP031129
Output Box 210-BP031140
Mounting Template Spectrum-68-Temp
Clear LED White Light Spectrum100
Frosted LED White Light Spectrum101

Contact

A division of Bathing Brands,Inc.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BATHOLOGY User Manuals

Related Manuals