BATHOLOGY Spectrum 510 Color Bathing LED RGB Lighting System User Manual

July 17, 2024
BATHOLOGY

PATHOLOGY Spectrum 510 Color Bathing LED RGB Lighting System

Specifications

DMX Driver Led Light

Operating Voltage: 24V DC
Power Consumption: 4.2 – 12.6 watts per channel
Output Voltage: 12-36V DC
Output Current: 350mA Constant Current
Zones: 1 Zone RGB
Beam Angle: 88 Lumens
Trim Finish: Stainless Steel
Housing: Stainless Steel
Lens Composition: Tempered Glass
Connection: RJ45 Cat6| Operating Voltage: 24V DC
Power Consumption: 3 Watts
Led Type: RGB
Lumens: 88
Trim Finish: Stainless Steel
Housing: Stainless Steel
IP Rating: IP20
Certifications: UL, CE, FCC, CRUus

Product Usage Instructions

Installation

  1. Ensure all wiring is done by a certified electrician following national electric code and local building codes.
  2. Install electrical components in a moisture-free location protected from weather elements.
  3. Consider maximum temperature ratings of components and avoid exceeding them to maintain warranty.
  4. Avoid placing LED lights directly above the steam outlet and position them carefully to prevent eye contact.
  5. Place the Light Control thoughtfully considering electrical and plumbing fixtures.
  6. Mount the Spectrum 510 control inside the Steam Room at a maximum of 48″ above the floor.
  7. Do not install the control on the same wall or within 24″ of the steam outlet.

SAFETY & WARNINGS

PLEASE READ THIS MANUAL IN ITS ENTIRETY PRIOR TO INSTALLATION!

  1. All wiring must be done in accordance with national electric code and local building codes by a certified electrician.
  2. All electrical components such as driver and power supply must be installed in a location protected from moisture, rain, and or inclement weather.
  3. Please note the maximum temperature ratings of all components on page 4 Specifications. Components should not be installed where maximum temperature of component will be exceeded, doing so will void warranty.
  4. Do not install Led lights directly above steam outlet.
  5. Consider light placement carefully. Each Led light should be placed to avoid direct contact with the bathers eyes.
  6. Prior to installation, consider the placement of the Light Control carefully, taking into account the location of electrical, plumbing, and other fixtures.
  7. The Spectrum 510 control is designed for installation inside of the Steam Room at a maximum of 48” above the floor.
  8. The control should not be installed on the same wall or within 24” of steam outlet
  9. The maximum light cable distance from Driver to farthest light is 100’.
  10. All system components should be tested prior to final installation.
  11. Always fully disconnect power from the system prior to making or disconnecting any connections.

Electrical Requirements
Always turn off the power at the breaker box before starting any electrical work.

  • A 120V AC electrical outlet is needed to power the lighting system.
  • Your electrician will determine the type of electrical outlet, box, and pip-ing to be used.
  • Improper voltage or connections will damage the components and void warranty.

PACKAGE CONTENTS

BATHOLOGY-Spectrum-510-Color-Bathing-LED-RGB-Lighting-System-
\(2\) BATHOLOGY-Spectrum-510-Color-
Bathing-LED-RGB-Lighting-System- \(3\)

SPECIFICATIONS

DMX Driver

  • Operating Voltage: 24V DC
  • Power Consumption: 4.2 – 12.6 watts per channel
  • Output Voltage: 12-36V DC
  • Output Current: 350mA Constant Current
  • Connections: Power In – DC Female Barrel
  • DMX In/Out – RJ45 Cat6
  • Led Out – RJ45 Cat6
  • Zones: 1 Zone RGB
  • Operating Temp: -4°F – 122°F
  • Dimensions: 7”L x 1.81”W x .82”H
  • Light Capacity: 6 (per Driver)
  • IP Rating: IP20
  • Certifications: UL, CE. FCC, CRUus

RGB Control

  • Output Signal: DMX
  • Operating Voltage: 24VDC
  • Power Consumption: 500mA
  • Material: Aluminum Housing / Glass Face
  • Connections: Power In – DC Female Barrel
  • DMX In – RJ45 Cat6
  • Mounting: Double Sided Adhesive/Silicone
  • Dimensions: 4.72”L x 3”W x .59”H
  • Operating Temp: 32°F – 122°F
  • Zones: 1 Zone RGB
  • IP Rating: IP67
  • Certifications: CE

Power Supply

  • Input Voltage: 120VA C
  • Output Voltage: 24V DC
  • Rated Power: 90W
  • AC Current: 1.3A
  • DC Current: 3.75A
  • Operating Temp: -22°F – 158°F
  • IP Rating: IP20
  • Certifications: UL, CE, FCC

Led Light

  • Operating Voltage: 24V DC
  • Power Consumption: 3 Watts
  • Led Type: RGB
  • Lumens: 88
  • Trim Finish: Stainless Steel
  • Housing: Stainless Steel
  • Beam Angle: 120° – Frosted Lens 35° – Clear Lens
  • Lens Composition: Tempered Glass
  • Connection: RJ45 Cat6
  • Rough-In Cutout: 1-5/8”
  • Trim Dimensions: 2” Diameter, 18” Profile
  • Body Dimensions: 1-15/35” Diameter 1-7/8” Deep
  • Operating Temp: 0°F – 230°F
  • IP Rating: IP68
  • Certifications: CE, ROHS

CONNECTION OVERVIEW

BATHOLOGY-Spectrum-510-Color-Bathing-LED-RGB-Lighting-System-
\(5\)
BATHOLOGY-Spectrum-510-Color-Bathing-LED-RGB-Lighting-System-
\(6\)

INSTALLATION

  1. STEP 1 – DMX DRIVER

  2. At determined location mount DMX driver.
    Note: DMX driver must be installed in a dry accessible location or inside a waterproof electrical enclosure.

  3. Take Output box and mount next to DMX driver. See Figure 1

  4. Route 50’ dc power cable from DMX driver location to control location.
    Note: Male end of dc cable connects to control.

  5. Route 25’ CAT6 cable from DMX driver location to control location

  6. At DMX driver take 25’ CAT6 cable ran to control and plug into DMX in lead on DMX driver.

  7. Route 25’ CAT6 cable from Output box to light location. Repeat this step for each additional light.
    Note: Refer to pages 9-12 for Output Box connections.

  8. Take 4 port DC splitter and connect one male end to power in on DMX driver. Connect second male end to 50’ dc power cable for control.

  9. Take 1’ Cat6 cable and connect one end to light out lead on DMX driver and other end to in port A of Output box.
    Note: Each lead/driver handles 6 lights max. For more than 6 lights a separate driver kit must be purchased.

  10. After checking and verifying all connections at driver and output box proceed to Led light installation.

  11. STEP 2 – BRILLIANCE LED LIGHTS

  12. Locate mounting plate and install at each light loca-tion by fastening plate to ceiling joist or wall stud. See figure 3

  13. After finished material is installed use the 1-5/8” hole saw and power drill, drill a hole for each light.

  14. After drilling hole ensure any installation is pushed to the side to maintain at least 2” clearance from top and sides of light.

  15. Take female RJ45 connector from light and plug into RJ45 cable from DMX driver.

  16. Run a 1/8” bead of silicone around edge of light for wet applications. See figure 3

  17.  Take light and push up into opening until trim is flush with surface.

  18. Back at DMX driver plug Cat 6 cables from each light into 12 port splitter box. Note: Repeat above steps for each additional light.
    Note: Refer to pages 9-12 for output box connec-tions and setup.

  19. STEP 3 – CONTROL

  20. At determined control location cut a 1-1/2” x 2-13/32 square hole to mount control.

  21. Take the 25’ CAT6 cable run from DMX driver and plug into RJ45 pigtail on control.

  22. Take 50’ DC Power Cable and plug into DC pigtail on control.

  23. Remove backing off double sided adhesive.

  24. Run a continuous bead of silicone on back side of control.

  25. Press control onto wall ensuring level and secure. Wipe away any access silicone.

BATHOLOGY-Spectrum-510-Color-Bathing-LED-RGB-Lighting-System-
\(9\)

  1. STEP 4 – STARTUP & TESTING

  2. After completing all installation steps take 4 port DC splitter and plug Female end into Male end from power supply.

  3. Plug power supply into 120VAC outlet.

  4. Verify DMX driver lights up and screen displays 001
    Note: If driver is not displaying 001 or any other number upon applying power proceed to troubleshooting steps on page #13.

  5. At control press power button to turn on lights. Verify all lights in room come on and cycle through colors.

If you encounter any issues during startup refence page # 13 for troubleshooting steps.

OUTPUT BOX SETTINGS

Note: Input A will handle up to 6 lights.

BATHOLOGY-Spectrum-510-Color-Bathing-LED-RGB-Lighting-System-
\(10\) BATHOLOGY-Spectrum-510-Color-
Bathing-LED-RGB-Lighting-System- \(11\) BATHOLOGY-Spectrum-510-Color-Bathing-LED-RGB-Lighting-System-
\(12\) BATHOLOGY-Spectrum-510-Color-
Bathing-LED-RGB-Lighting-System- \(13\)

TROUBLESHOOTING

No Power

  • Verify electrical outlet has proper voltage.
  • Check that connections on DC splitter secure and connected.

Power but lights not turning on

  • Check DMX CAT6 cable from driver to control is secure and connected.
  • Check DC power cable from driver to control is secure and connected.
  • Check 1’ CAT6 cable to output box is secure and connected on both ends.
  • Check all 25’ CAT6 cables to lights are secure and connected.
  • Verify correct setup on output box for the amount of lights. See pages 9-12
  • Verify each light functions by testing directly to driver independently.
  • Note: If one light goes bad with multiple lights all lights will shut off as lights are in series.

Lights on no function from Control

  • Check DMX CAT6 connections at control and driver are secure and connected.
  • Check DC power cable from driver to control is secure and connected.

DMX Driver Menu Settings
To access menus to verify or troubleshoot follow steps bellow, see figure 5 for reference.

Channel Menu

  1. Press and hold buttons #2 and #3 at the same time for 3-5 seconds, screen will flash.
  2. Press button #1 until 1ch displays.
  3. Press and hold any button for 3-5 seconds to exit and save setting.

Mode Menu

  1. Press and hold buttons #1 and #2 at the same time for 3-5 seconds, screen will flash.
  2. Press button #3 until ru2 displays.
  3. Press and hold any button for 3-5 seconds to exit and save setting.

DMX Address Menu

  1. Press and hold button #1 for 3-5 seconds, screen will flash.
  2. Press button #1, #2, and #3 until 001 displays.
  3. Press and hold any button for 3-5 seconds to exit and save setting.

PWM Frequency Menu

  1. Press and hold button #1 and #3 for 3-5 seconds, screen will flash and display P – c.
  2. Press button #1, until 2 displays. Press button #3 until 2 displays. Screen should display 2 – 2
  3. Press and hold any button for 3-5 seconds to exit and save setting.

REPLACEMENT PARTS

Description Part Number

DMX Driver 350mA

|

BP031122

Touch Control RGB

|

SPECTRUM097

LED Light, RGB, Clear

|

SPECTRUM098

LED Light, RGB, Frosted

|

SPECTRUM099

Power Supply 90 watt

|

BP031137

Output Box

|

BP031140

AC Power Cord

|

BP031132

4 Port DC Splitter

|

BP031138

50’ DC Power Cable

|

BP031134

RJ45 Pigtail Cable

|

BP031141

DC Pigtail Cable

|

BP031143

25’ CAT 6 Cable

|

BP031129

1’ CAT 6 Cable

|

BP031128

Mounting Template

|

SPECTRUM-68-TEMP

Driver Kit for Additional Lights 7-12 (does not come with lights)|

SPECTRUM201

Spectrum510
REV – 2.0-02/2024
© 2024 Bathing Brands, Inc.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>