BATHOLOGY Spectrum 440D Steam White Light System Instruction Manual

June 1, 2024
BATHOLOGY

Spectrum 440D Steam White Light System

“`html

Product Specifications

  • Product Name: Spectrum 440D Steam White Light System
  • Power Source: 120VAC Grounded
  • Control: External light switch (by others)
  • Installation: Requires a licensed, qualified electrician
  • Safety: Use safety goggles during installation

Product Usage Instructions

Installation Considerations

– Read the manual entirely before installation.
– Do not hot swap any electrical components.
– Review all installation options and instructions carefully.
– Use safety goggles at all times.
– Ensure the light switch is not reachable from tub or
shower.
– Check for piping/electrical before cutting or drilling.
– All wiring must comply with National Electric Code and local
building code.
– Install the system by a licensed electrician.
– Avoid placing fixtures directly in contact with bather’s
eyes.

Installation Steps

1. Identify desired switch location outside the steam
area.
2. Allow for 2 inches of clearance from insulation around the
fixture.
3. Follow the package contents list for proper installation
materials.
4. Install the driver, enclosure, strain relief bushings, and other
components as per the diagram.
5. Connect the necessary cables and wires according to the
electrical diagram provided.
6. Ensure all connections are secure and insulated before powering
on the system.

Electrical Diagram

– The diagram illustrates the connections between the dimmer,
light cable, male NEMA cable, and other electrical
components.
– Follow the color-coding and connection instructions for a safe
and functional installation.

Frequently Asked Questions (FAQ)

Q: Can I install the Spectrum 440D system myself?

A: It is recommended to have the system installed by a licensed,
qualified electrician to ensure safety and compliance with
regulations.

Q: What should I do if I need additional lights for the

system?

A: Purchase additional lights and ensure to increase quantities
of specific components indicated with an asterisk (*) per
additional light purchased.

Q: What safety precautions should I take during

installation?

A: Always wear safety goggles, avoid hot swapping electrical
components, and ensure all wiring is done following relevant codes
and guidelines.

“`

Spectrum 440D
Steam White Light System
Installation and Operation Manual

Spectrum 440D
Contents
Installation Considerations ——————————————— 3 Installation ————————————————————— 4 Electrical Diagram —————————————————— 6 Product Care ————————————————————- 11 Specifications ———————————————————— 12 Notes ——————————————————————— 13 Replacement Parts ——————————————————- 13
2

Installation Considerations
Please read this manual in its entirely prior to installation

IMPORTANT: DO NOT HOT SWAP ANY ELECTRICAL COMPONENTS. This will void the warranty, and likely cause the
product to fail.

Carefully review all installation options and instructions before proceeding.
For safety purposes, use safety goggles at all times.

The Spectrum 440D Steam White Light System can be controlled by the use of a light switch provided by others. NEVER place a switch where it can be reached from a tub or shower.

Do not hot swap any electrical components. This will void the warranty, and likely cause the product to fail. Fully disconnect the system from its power source before swapping any electrical components.
Check for piping / electrical before cutting or drilling.
Some electrical components are not waterproof.

! IMPORTANT All wiring must be done in accordance with National Electric Code and local building code.
! IMPORTANT The Spectrum 440D White Light System should be installed by a licensed, qualified electrician.
! IMPORTANT Consider light placement carefully. The fixture(s) for this system should be placed to avoid direct contact with the bather’s eyes.

If there is any risk of uninsulated electrical connections in your wall / ceiling area, use insulating gloves.

3

Spectrum 440D
Installation
I

Steam

K

J

Desired Switch Location (must be placed outside
the steam)

Allow for 2″ of clearance from insulation above and around fixture.
L
B

Package Includes

Item Quantity

Description

Item Quantity

Description

A

1

Driver

2

Enclosure Top Screws

1

Screw

4

Screws / Anchors

1

Locknut

4

Wire Nuts

B

1

Enclosure

1

Ground Connector

1

Enclosure Top

C

2

Strain Relief Bushings

4

G

For 2-6 lights Output Box will be used. Plug 1′ Cat6 cable into E and
into A of Output Box.

Accessible, dry location

B 6

B 5

B 4

B 3

B 2

B 1

OUTPUT

E

H

O N
B 12345678 9

1
2 ON: 1,2,3,4 OFF: 5,6,7,8,9
3 4 5 ON: 5,6,7,8 6 OFF: 1,2,3,4,9

(A/B) 2,3,4 (A/B) 3,4 (A/B) 4
(A/B) 6

B

12 3 4 5 6 78 9

INPUT

ON ON

DIP

O N
A 12345678 9

Lights

DIP Switch (A/B)

Terminator position

A

OUTPUT

A 6

A 5

A 4

A 3

A 2

A 1

D

C C
A

120VAC Grounded Power Source (Controlled by switch by others. NEVER place a switch where it can be reached
from a tub or shower)
IMPORTANT: DO NOT HOT SWAP ANY ELECTRICAL COMPONENTS

PHYSICALLY UNPLUG FROM POWER SOURCE BEFORE SWAPPING ELECTRICAL COMPONENTS

Package Includes

Item Quantity

Description

Item Quantity

Description

D

1

Male NEMA Cable

I

1*

Mounting Template

E

1

Light Cable

J

1*

Brilliance Light Fixture

F

1

Cat6 Cable, 1′

K

1*

Wire Fit Cap

G

1*

Cat6 Cable, 25′

1

Silicone Sealant, 1 ounce

H

1

Output Box

L

1

Dimmer

NOTE: Quantity with an * increases by one per each additional light purchased. Quantities shown
assume no additional lights purchased with Spectrum 440D system.
5

Spectrum 440D
Electrical Diagram

L Dimmer

Light Cable E

Gray Purple

Electrical Outlet Male NEMA Cable D

Neutral Ground
Switch Leg

White

Blue

A

Driver

B Enclosure

Neutral Hot

Ground

Field Supplied Factory Supplied
NOTE: Neutral from Electrical Panel not needed for Dimmer, but passes through to Electrical Outlet.
6

Electrical Panel

Electrical Detail

  1. Electricla Panel to Dimmer (L)

a) The Dimmer (F) will make use of a 120VAC, 15 Amp branch circuit. The Dimmer (L) should be place where most convenient for operation. The Dimmer (L) must be installed outside the Steam Room. Never place a switch where it can be reached from a tub or shower.

b)

ELECTRICAL PANEL ———-> DIMMER (L)

Ground

Ground

Neutral

(passes through to Outlet)

Hot

Black

  1. Dimmer (L) to Electrical Outlet

a)

DIMMER (L) ———–> ELECTRICAL OUTLET

Ground

Ground

(Neutral from Panel) Neutral

Red

Hot

  1. Driver (A) to Dimmer (L)

a)

DRIVER (A) ———-> DIMMER (L)

Blue

Purple

White

Gray

7

Spectrum 440D

Installation (Continued)

IMPORTANT: DO NOT HOT SWAP ANY ELECTRICAL COMPONENTS. This will void the warranty, and likely cause the
product to fail.

1. Install a standard single gang electrical box in an accessible, dry location.

Accessible, dry location

2. Run a grounded 120VAC from the power supply to the accessible, dry location’s electrical box.

120VAC Grounded Power Source

3. Secure enclosure (B) to wall in an accessible, dry location using provided screws / anchors.

Accessible, dry location

E

D

C

E
Black – Black Red – White

D
Brown – Black Blue – White Ground – GND

Typical Installation

A

B

A

Typical Installation

120VAC Grounded Power Source

Accessible, dry location
D E

B
Typical Installation
8

Installation (Continued)
4. Determine number of lights per input. Limit 6 lights per input.
5. Determine desired brilliance light fixture (J) location. Note: Fixture should be placed to avoid direct contact with the bather’s eyes. Allow for 2″ clearance from insulation above and around the fixture.

A6

A5

A4

A3

A2

A1

OUTPUT

ON
A 1 2 3 4 5 6 7 8 9

ON ON

DIP

12 3 4 5 6 78 9

ON
B 1 2 3 4 5 6 7 8 9

Lights

DIP Switch (A/B)

Terminator position

1
2 ON: 1,2,3,4 OFF: 5,6,7,8,9
3 4 5 ON: 5,6,7,8 6 OFF: 1,2,3,4,9

(A/B) 2,3,4 (A/B) 3,4 (A/B) 4
(A/B) 6

OUTPUT

B6

B5

B4

B3

B2

B1

A

INPU T

B

2″ Clearance from insulation above and around the fixture.

6. Optional: Mount 16″ location template (I) to ceiling / wall framework. Use notches to quickly align desired location to other fixtures in the room.

16″ Location Template I
1″ Ceiling / Wall
Material

Joist

Joist

Joist

Desired Fixture Location

Joist

Notch used to align fixture center to other
fixture centers

I
16″ Location Template

9

Spectrum 440D

Installation (Continued)

7. Make a 1-5/8″ hole in desired location.

Bathing Space

1-5/8″

8. For Wet environments, apply a 1/8″ bead of silicone around the edge of the light as required to form a water tight seal.

9. Mount brilliance light fixture (J)

to ceiling through 1-5/8″ cut-

out. Allow for 2″ clearance from

insulation above and around the

fixture.

J

10. Repeat steps 6 – 9 for each light.

11. Allow silicone to cure for 24 hours before exposing product to any source of moisture.

1/8″ bead of

silicone for wet

J

environments

10

Product Care
For routine cleaning, simply use a soft damp cloth and common household soap. Use a damp cloth to wipe clean, then dry. Clean product frequently to avoid calcium deposits on surfaces. Use only mild soap. Never use abrasive cleaners, bleach, disinfectants or cleaning products containing alcohol, ammonia, hydrochloric or phosphoric acids as they may damage the product’s finish. To clean electrical components, gently wipe down using a dry cloth or duster. Never use a wet duster, water, or any other liquid to clean the device.
11

Spectrum 440D

Terminator

2 Lights

Terminator

3 Lights

A

INPU T

A6

A5

A4

A3

A2

A1

OUTPUT

ON
A 1 2 3 4 5 6 7 8 9

ON ON

DIP

12 3 4 5 6 78 9

ON
B 1 2 3 4 5 6 7 8 9

Lights

DIP Switch (A/B)

Terminat position

1

2

ON: 1,2,3,4 OFF: 5,6,7,8,9

3

4

5 ON: 5,6,7,8 6 OFF: 1,2,3,4,9

(A/B) 2,3,4 (A/B) 3,4 (A/B) 4
(A/B) 6

OUTPUT

B6

B5

B4

B3

B2

B1

INPU T

B

A

A6

A5

A4

A3

A2

A1

OUTPUT

ON
A 1 2 3 4 5 6 7 8 9

ON ON

DIP

12 3 4 5 6 78 9

ON
B 1 2 3 4 5 6 7 8 9

Lights

DIP Switch (A/B)

1 2 ON: 1,2,3,4 3 OFF: 5,6,7,8,9 4

5 ON: 5,6,7,8 OFF: 1,2,3,4,9
6

Terminat position
(A/B) 2,3,4 (A/B) 3,4 (A/B) 4
(A/B) 6

OUTPUT

B6

B5

B4

B3

B2

B1

B

4 Lights

Terminator

5 Lights

A

INPU T

A6

A5

A4

A3

A2

A1

OUTPUT

ON
A 1 2 3 4 5 6 7 8 9

ON ON

DIP

12 3 4 5 6 78 9

ON
B 1 2 3 4 5 6 7 8 9

Lights

DIP Switch (A/B)

1
2 ON: 1,2,3,4 3 OFF: 5,6,7,8,9
4
5 ON: 5,6,7,8 6 OFF: 1,2,3,4,9

Terminat position
(A/B) 2,3,4 (A/B) 3,4 (A/B) 4
(A/B) 6

OUTPUT

B6

B5

B4

B3

B2

B1

INPU T

B

A

A6

A5

A4

A3

A2

A1

OUTPUT

ON
A 1 2 3 4 5 6 7 8 9

ON ON

DIP

12 3 4 5 6 78 9

ON
B 1 2 3 4 5 6 7 8 9

Lights

DIP Switch (A/B)

1
2 ON: 1,2,3,4 3 OFF: 5,6,7,8,9
4
5 ON: 5,6,7,8 6 OFF: 1,2,3,4,9

Terminat position
(A/B) 2,3,4 (A/B) 3,4 (A/B) 4
(A/B) 6

OUTPUT

B6

B5

B4

B3

B2

B1

B

6 Lights

A

INPU T

A6

A5

A4

A3

A2

A1

OUTPUT

ON
A 1 2 3 4 5 6 7 8 9

ON ON

DIP

12 3 4 5 6 78 9

ON
B 1 2 3 4 5 6 7 8 9

Lights

DIP Switch (A/B)

1
2 ON: 1,2,3,4 3 OFF: 5,6,7,8,9
4
5 ON: 5,6,7,8 6 OFF: 1,2,3,4,9

Terminat position
(A/B) 2,3,4 (A/B) 3,4 (A/B) 4
(A/B) 6

OUTPUT

B6

B5

B4

B3

B2

B1

B

12

8 Lights

A

INPU T

A6

A5

A4

A3

A2

A1

OUTPUT

ON
A 1 2 3 4 5 6 7 8 9

ON ON

DIP

12 3 4 5 6 78 9

ON
B 1 2 3 4 5 6 7 8 9

Lights

DIP Switch (A/B)

1
2 ON: 1,2,3,4 3 OFF: 5,6,7,8,9
4
5 ON: 5,6,7,8 6 OFF: 1,2,3,4,9

Terminat position
(A/B) 2,3,4 (A/B) 3,4 (A/B) 4
(A/B) 6

OUTPUT

B6

B5

B4

B3

B2

B1

B

Terminator

10 Lights

9 Lights

A

INPUT

A6

A5

A4

A3

A2

A1

OUTPUT

ON
A 1 2 3 4 5 6 7 8 9

ON ON

DIP

12 3 4 5 6 78 9

ON
B 1 2 3 4 5 6 7 8 9

Lights

DIP Switch (A/B)

1 2 ON: 1,2,3,4 3 OFF: 5,6,7,8,9
4 5 ON: 5,6,7,8 6 OFF: 1,2,3,4,9

Terminator position
(A/B) 2,3,4 (A/B) 3,4 (A/B) 4
(A/B) 6

OUTPUT

B6

B5

B4

B3

B2

B1

B

Terminator

11 Lights

A

INPU T

B

A6

A5

A4

A3

A2

A1

OUTPUT

ON
A 1 2 3 4 5 6 7 8 9

ON ON

DIP

12 3 4 5 6 78 9

ON
B 1 2 3 4 5 6 7 8 9

Lights

DIP Switch (A/B)

1
2 ON: 1,2,3,4 3 OFF: 5,6,7,8,9
4
5 ON: 5,6,7,8 6 OFF: 1,2,3,4,9

Terminat position
(A/B) 2,3,4 (A/B) 3,4 (A/B) 4
(A/B) 6

OUTPUT

B6

B5

B4

B3

B2

B1

INPU T

B

A

A6

A5

A4

A3

A2

A1

OUTPUT

ON
A 1 2 3 4 5 6 7 8 9

ON ON

DIP

12 3 4 5 6 78 9

ON
B 1 2 3 4 5 6 7 8 9

Lights

DIP Switch (A/B)

1
2 ON: 1,2,3,4 3 OFF: 5,6,7,8,9
4
5 ON: 5,6,7,8 6 OFF: 1,2,3,4,9

Terminat position
(A/B) 2,3,4 (A/B) 3,4 (A/B) 4
(A/B) 6

OUTPUT

B6

B5

B4

B3

B2

B1

Terminator
12 Lights

A

INPU T

A6

A5

A4

A3

A2

A1

OUTPUT

ON
A 1 2 3 4 5 6 7 8 9

ON ON

DIP

12 3 4 5 6 78 9

ON
B 1 2 3 4 5 6 7 8 9

Lights

DIP Switch (A/B)

1 2 ON: 1,2,3,4 3 OFF: 5,6,7,8,9
4 5 ON: 5,6,7,8 6 OFF: 1,2,3,4,9

Terminat position
(A/B) 2,3,4 (A/B) 3,4 (A/B) 4
(A/B) 6

OUTPUT

B6

B5

B4

B3

B2

B1

B

13

Spectrum 440D

Specifications

Driver Operating Voltage: 120 VAC Output Voltage: 700mA Power Consumption: 35W Nominal Amperage: 1.1 Amps Dimensions: 5-7/8″ W x 1-1/8″ H x 1-5/8″ D Brilliance Fixture Type: LED Cool White (5650-6300K) Operating Voltage: 12VDC Maximum Input Current: 700mA LED: 1 x 3 Watt Beam Angle: 35°Clear/120°Frosted Trim Finish: Polished Stainless Steel

Enclosure Housing Composition: Steel, black powder coated finish Dimensions: 7-3/4″ W x 1-7/8″ H x 4-7/8″ D Standards: NEMA 1 Listing: ETL, UL
Construction Template Composition: Steel, Galvanized, Gauge 22 Dimensions: 15-1/8″ L x 1/32″ H x 3″ D

Housing Composition: Stainless Steel
Lens: Clear or Frosted, 1-7/32″ Diameter

Dimmer Type: 0-10V

Lens Composition: Tempered Glass Rough-in Cutout: 1-5/8″ to 1-11/16″

Trim Dimension: 2-3/64″ Diameter, 1/8″ Profile

Body Dimensions: 1-15/32″ Diameter x 1-7/8″ Deep

Rating: IP68

Certifications: CE / RoHS / WEEE

Max Operating Temperature: 130°F when installed per instructions

14

Notes

Replacement Parts
Contact your Bathology representative for Spectrum 440D Steam White Light System
replacement parts.
800-957-2862
www.Bathology.com

Description Driver Enclosure Strain Relief Bushings Male NEMA Cable Cat6 Cable, 1′ Cat6 Cable, 25′ Output Box Mounting Template Clear LED White Light Frosted LED White Light

Part Number Spectrum114 Spectrum079 Spectrum077 Spectrum038 210-BP031128 210-BP031129 210-BP031140 Spectrum-68-Temp Spectrum100 Spectrum101

15

Spectrum 440D
Notes
16

Notes
17

www.Bathology.com 800-957-2862 A division of Bathing Brands,Inc.

Rev-08 12/23

Spectrum440D 900-0142-1019