MEAN WELL SPV-150-48 Enclosed Power Supply
Specifications :
- Model: SPV-150 series
- Output Power: 150W
- Input: Universal AC input / Full range
- PFC Function: Built-in active PFC function, PF>0.94
- Protections: Short circuit, Overload, Over voltage, Over temperature
- Cooling: Free air convection
- Output Voltage Programmable: 20~110% by 1~5.5VDC external control signal
- Remote ON-OFF Control: Built-in
- Switching Frequency: Fixed at 100KHz
- Warranty: 3 years
Product Usage Instructions
Installation :
- Ensure the input power matches the specified voltage range (88 ~ 264VAC).
- Connect the output to the intended device, ensuring proper polarity.
- For voltage adjustment, use a 1~5.5VDC external control signal within the specified range.
Operation:
- Apply power to the unit within the specified input voltage range.
- Use the remote ON-OFF control for power management.
- Monitor for any abnormal operation or triggering of protection mechanisms.
Maintenance :
- Regularly check for dust accumulation and ensure proper ventilation for cooling.
- If encountering issues, refer to the user manual for troubleshooting steps.
FAQ :
-
Q: What is the warranty period for the SPV-150 series?
A: The product comes with a 3-year warranty. -
Q: How can I adjust the output voltage of the power supply?
A: The output voltage can be programmed from 20~110% by using a 1~5.5VDC external control signal -
Q: What are the main protections provided by the SPV-150 series?
A: The power supply offers protections against short circuit, overload, over voltage, and over temperature.
150W Single Output with PFC Function
Features
- Universal AC input / Full range
- Built-in active PFC function, PF>0.94
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Cooling by free air convection
- Output voltage programmable from 20~110% by 1~5.5VDC external control signal
- Built-in remote ON-OFF control
- Fixed switching frequency at 100KHz
- 3 years warranty
GTIN CODE MW Search: https://www.meanwell.com/serviceGTIN.aspx
SPECIFICATION
MODEL | SPV-150-12 | SPV-150-24 | SPV-150-48 |
---|---|---|---|
OUTPUT | DC VOLTAGE | 12V | 24V |
RATED CURRENT | 12.5A | 6.25A | 3.125A |
CURRENT RANGE | 0 ~ 12.5A | 0 ~ 6.25A | 0 ~ 3.125A |
RATED POWER | 150W | 150W | 150W |
RIPPLE & NOISE (max.) **Note.2** | 150mVp-p | 150mVp-p | 240mVp-p |
VOLTAGE ADJ. RANGE | 10.8 ~ 13.2V | 20 ~ 26.4V | 41 ~ 52.8V |
VOLTAGE TOLERANCE Note.3 | ±1.0% | ±1.0% | ±1.0% |
LINE REGULATION | ±0.3% | ±0.2% | ±0.2% |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% |
SETUP, RISE TIME | 800ms, 50ms/230VAC 2500ms, 50ms/115VAC at |
full load
HOLD UP TIME (Typ.)| 16ms/230VAC 16ms/115VAC at full load
INPUT| VOLTAGE RANGE Note.5| 88 ~ 264VAC 124 ~
370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.94/230VAC PF>0.98/115VAC at full
load
EFFICIENCY (Typ.)| 82%| 83%| 83%
AC CURRENT (Typ.)| 2.5A/115VAC 1.25A/230VAC
INRUSH CURRENT (Typ.)| 20A/115VAC 45A/230VAC
LEAKAGE CURRENT| <1mA / 240VAC
PROTECTION| OVERLOAD| 105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after
fault condition is removed
OVER VOLTAGE| 13.8 ~ 16.2V| 27.6 ~ 32.4V| 57.6 ~ 67.2V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after
temperature goes down
FUNCTION| REMOTE CONTROL| 4 ~ 10VDC power off, <0 ~ 0.8VDC power on
OUTPUT VOLTAGE TRIM| 2.4 ~ 13.2V| 4.8 ~ 26.4V| 9.6 ~ 52.8V
ENVIRONMENT| WORKING TEMP.| -20 ~ +65℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY EMC (Note 4)| SAFETY STANDARDS| UL60950-1, TUV BS
EN/EN62368-1, IEC62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS
EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS
EN/EN55024, light industry level, EAC TP TC 020
OTHERS| MTBF| 2112.6K hrs min. Telcordia SR-332 (Bellcore) ;
210.3K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 21511550mm (LWH)
PACKING| 1.1Kg; 12pcs/14Kg/0.92CUFT
NOTE|
- All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- Tolerance : includes set up tolerance, line regulation and load regulation.
- The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EM testing of component power supplies.” (as available on http://www.meanwell.com)
- Derating may be needed under low input voltages. Please check the derating curve for more details.
- The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx