Johnson Pump Aqua O2 Flex Mount 800 GPH Aerator Pump Installation Guide

June 16, 2024
Johnson Pump

Johnson Pump Aqua O2 Flex Mount 800 GPH Aerator Pump

Specifications

PART NUMBER| PUMP SIZE| DESCRIPTION| CAPACITY STRAIGHT (12V) GPH| CAPACITY STRAIGHT (12V) L/MIN| VOLTAGE| AMP| FUSE SIZE| HOSE CONN.| WEIGHT
---|---|---|---|---|---|---|---|---|---
10-13642-01| Aqua O2 Cartridge Aerator Pump| 500 GPH| 585| 37| 12V| 2.7A| 3.5A| 3/4″| 9.6 oz.
10-13649-01| Aqua O2 Cartridge Twin Port Aerator Pump| 800 GPH| 810| 51| 12V| 3.7A| 5A| 3/4″| 10.4 oz.

Features

  • High Flow Impeller Design – Heightened efficiency and an increased flow rate
  • Quick-Change Motor Connection – Enjoy quick and hassle-free cartridge motor changes or capacity upgrades
  • Reorient discharge in any direction – Unmatched versatility for ease of installation
  • Durable Thermoplastic Housing Design Commonality with Removable Motor Cartridge – A common body allows the interchangeable motor cartridge replacement to the same or different size
  • Water-cooled motor, 316 Stainless Steel Shaft and Permanently Lubricated Double Bearings – Corrosion-resistant and extended life
  • Dual Port Inlet – Allows single transom intake for dual intake pump application. Choose the correct intake for the application

Benefits

  • Heightened efficiency and increased flow rate compared to other pumps in the same capacity category
  • Quick and hassle-free cartridge motor changes or capacity upgrades
  • Versatile installation options with the ability to reorient discharge in any direction
  • Interchangeable motor cartridge replacement to the same or different size due to common body design
  • Corrosion-resistant and extended life due to water-cooled motor, 316 stainless steel shaft, and permanently lubricated double bearings
  • A dual port inlet allows for a single transom intake for dual intake pump application

Competitive Advantages

  • The most efficient and highest flow in GPH capacity category
  • Industry-first and only cartridge motor pump with included harness connection requiring no cutting and splicing of wires

Product Usage Instructions

Installation

  1. Choose the appropriate size of the Aqua O2 Aerator or Livewell Pump based on the desired flow rate.
  2. Ensure that you have the correct intake for your application, whether straight or 90-degree inlet.
  3. Position the pump in the desired location, ensuring it is securely mounted.
  4. Connect the hose to the pump’s hose connection, making sure it is tightly secured.
  5. Connect the pump to a suitable power source, ensuring correct voltage and fuse size.

Cartridge Motor Replacement

  1. Disconnect the pump from the power source.
  2. Remove the existing motor cartridge by following the manufacturer’s instructions.
  3. Take the replacement cartridge motor and align it with the pump’s motor housing.
  4. Securely attach the replacement cartridge motor to the pump’s motor housing.
  5. Reconnect the pump to the power source and test for proper functionality.

FAQ

Q: Can I use the Aqua O2 Aerator or Livewell Pump in saltwater environments?

A: Yes, the pump is corrosion-resistant and suitable for use in saltwater environments.

Q: Can I adjust the flow rate of the pump?

A: The Aqua O2 Aerator or Livewell Pump does not have an adjustable flow rate. However, you can choose a pump with a higher or lower capacity based on your flow requirements.

FEATURES


High Flow Impeller Design



Quick-Change Motor Connection


360° Pump Discharge Rotation


Durable Thermoplastic Housing Design Commonality with Removable Motor Cartridge


Water-cooled motor, 316 Stainless Steel Shaft and Permanently Lubricated Double Bearings


Upgradeable Motor Cartridge


Dual Port Inlet


Straight or 90-degree Inlet

AVAILABLE SIZES

500 GPH 12V

800 GPH 12V

BENEFITS

Heightened efficiency and an increased flow rate


Enjoy quick and hassle-free cartridge motor changes or capacity upgrades


Reorient discharge in any direction


The common body  allows  interchangeable motor cartridge replacement to the same or different size


Corrosion-resistant and extended life

Can increase or decrease capacity according to environment and flow needed
Allows single transom intake for dual intake pump application


Chose correct intake for the application

COMPETITIVE ADVANTAGES

The most efficient and highest flow in the GPH capacity category


Industry-first and only cartridge motor pump with included harness connection requiring no cutting and splicing of wires


Unmatched versatility for ease of installation

TECHNICAL SPECIFICATIONS

Cartridge Aerator Pump & Cartridge Twin Port Aerator Pump


PART

NUMBER

| ****

PUMP SIZE

| ****

DESCRIPTION

| CAPACITY

STRAI G HT ( 12 V)

| ****

VOLTAG E

| ****

AM P

| ****

FUSE SIZE

| ****

HOSE CON N.

| ****

WE I G HT

---|---|---|---|---|---|---|---|---
G PH| L/ MIN
10-13642-01| ****

500

GPH

| Aqua O2 Cartridge Aerator Pump| ****


585

| ****


37

| ****


12V

| ****


2.7A

| ****


3.5 A

| ****


3/4″

| ****


9.6 oz.

10-13649-01| Aqua O2 Cartridge Twin Port Aerator Pump
10-13643-01| ****

800

GPH

| Aqua O2 Cartridge Aerator Pump| ****


810

| ****


51

| ****


12V

| ****


3.7A

| ****


5 A

| ****


3/4″

| ****


10.4 oz.

10-13650-01| Aqua O2 Cartridge Twin Port Aerator Pump

All Aqua O2 Cartridge Aerator Pumps offer the convenience of using only one intake for both the livewell and wash-down pump. Aqua O2 Cartridge Aerator Pump includes 3/4 NPSM thru-hull inlet that can be used as straight or 90°. Aqua O2 Cartridge Twin Port Aerator Pump only includes 3/4 NPT seacock inlet.

Standard Features: All Cartridge Aerator Pumps

BODY ABS DURA PORT PA66/GF – Nylon
SHAFT 316 Stainless Steel SHAFT S EAL Nitrile Rubber
MOTOR CARTR I DGE PC-ABS WIRE SIZE 16 GA, TINNED

Cartridge Motor: Replacement Cartridge

PART

NUMBER

| PUMP SIZE| DESCRIPTION
---|---|---

09-36336-01

| 500

GPH

|

Aqua Series Replacement Cartridge Motor

09-36336-06

| 800

GPH

|

Aqua Series Replacement Cartridge Motor

360° Rotation – Reorient Discharge in Any Direction

SPX FLOW, Inc. reserves the right to incorporate our latest design and material changes without notice or obligation. Design features, materials of construction and dimensional data, as described in this bulletin, are provided for your information only and should not be relied upon unless confirmed in writing. Please contact your local sales representative for product availability in your region. The green “ ” is a trademark of SPX FLOW, Inc. For more information, visit

©2023 SPX FLOW, Inc. JP_O2_FLR_US

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals