Product Specifications :
- Model: RSDH-300-12, RSDH-300-24, RSDH-300-32, RSDH-300-48
- DC Voltage: 12V, 24V, 32V, 48V
- Rated Current Range: 0 ~ 20A, 0 ~ 12.5A, 0 ~ 9.37A, 0 ~ 6.25A
- Rated Power: 240W, 300W, 300W, 300W
- Output Ripple & Noise (max.): 120mVp-p
- Voltage Adjustment Range: 12 ~ 15V
- Efficiency (Typ.): 87% – 91%
- Voltage Range: 250 ~ 1500Vdc
- Inrush Current (max.): 500A/1500Vdc, 300A/800Vdc, 120A/300Vdc
- External Input Fuse Overload: 4A/1500VDC
Product Usage Instructions
Installation :
- Ensure the input voltage matches the range specified for the converter.
- Connect the input and output terminals following the polarity markings.
- Securely mount the converter in a well-ventilated area to prevent overheating.
Operation :
- Apply power to the input within the specified voltage range.
- Adjust the output voltage within the provided adjustment range as needed.
- Monitor the device for any unusual noises or excessive heat during operation.
Maintenance :
- Regularly check for loose connections and signs of wear on the input and output terminals.
- Clean the converter periodically to prevent dust buildup that can affect performance.
- Follow recommended inspection schedules to ensure continued reliable operation.
Frequently Asked Questions (FAQ):
-
Q: What should I do if the converter overheats during operation?
A: Ensure proper ventilation around the converter and check for any obstructions blocking airflow. If the issue persists, contact customer support for assistance. -
Q: Can I use this converter with input voltages outside the specified range?
A: No, it is essential to strictly adhere to the specified voltage range to prevent damage to the converter and ensure safe operation. -
Q: How can I adjust the output voltage of the converter?
A: Use a suitable tool to adjust the voltage within the provided adjustment range mentioned in the user manual.
300W High Reliable 250~1500Vdc Ultra Wide Input DC-DC Converter
RSDH-300 series
Features
- 250 ~ 1500Vdc 6:1 ultra-wide input range
- Withstand 1700Vdc surge input for 10 seconds
- 4KVac 1/0 high isolation(Reinforced isolation)
- Protections: Short circuit / Overload / Over voltage / Over temperature DC input under voltage / DC input reverse polarity
- Fanless design, half encapsulated, cooling by free air convection
- -40~+80°C ultra-wide operating temperature (> +55°C derating)
- Over voltage category
- Operating altitude up to 5000 meters
- DC output voltage adjustable(12~15V, 24~29V, 30~36V, 48~58V)
- 1U low profile 41mm
- 3 vears warranty
Applications
- Photovoltaic power generation
- Renewable Energy System
- High voltage frequency conversion
- Industrial control system
- Semiconductor fabrication equipment
- Electro-mechanical apparatus
- DC bus centralized application
- Energy storage system(ESS)
- Charging pile
- Third rail
- GTIN CODE MW Search: HTTP//:www.meanwell.comserviceGTIN.asox
Description
RSDH-300 series is a 250 ~ 1500Vdc ultra-high input enclosed type DC-DC converter which can supply stable working voltage for the load. Main features are as following: -40~+80° C wide range operating temperature, 4KVac high isolation voltage, operation at 5000m altitude, high efficiency, low ripple & noise, complete protections and so on. RSDH-300 is compliant with BS EN/EN-61000-6-2 standard regarding immunity for industrial environments. It is suitable for industrial automation, surveillance, telecommunication and can be widely deployed in the applications of new energy generation such as solar power, and windmill power generation, for instances, photovoltaic power systems, high voltage inverting, DC bus centralized application, ESS, charging pile, railway and so forth.
Model Encoding
SPECIFICATION
Note
- All parameters NOT specially mentioned are measured at 800Vdc input, rated load and 25 C of ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1 uf & 47 uf parallel capacitor.
- Tolerance : includes set up tolerance, line regulation and load regulation.
- Derating may be needed under low input voltage. Please check the derating curve for more details
- The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft).
- The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Block Diagram
- Derating Curve
- Static Characteristics
Altitude Curve
Note: Multiply by the regular power limit factor
Input Terminal Pin No. Assignment (TB1)
Pin No. | Assignment |
---|---|
1 | +Vin |
2 | -Vin |
Output Terminal Pin No Accountment (TR2)
Pin No. | Assignment |
---|---|
1 | FG |
2 | -Vo |
3 | +Vo |
External FUSE wiring instruction External FUSE is required. FUSE
specification: 4A/1500Vdc.
Suggested model:
Installation Manual Please refer to :
- http://www.meanwell.com/manual.html
- File Name: RSDH-300-SPEC 2023-07-07
- Downloaded from Arrow.com.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>