GuangDong A320 Aroma Diffuser Instruction Manual

June 1, 2024
Guangdong

GuangDong A320 Aroma Diffuser

GuangDong-A320-Aroma-Diffuser-product

FAQ

  • Q: How do I calibrate the diffuser?
    • A: Enter the current essential oil volume, confirm, and let the diffuser run for at least 10 days to measure remaining oil.
  • Q: How do I change the intensity settings?
    • A: Press +/- to adjust intensity grades from 1-20 and customize spray times if needed.
  • Q: What should I do if I forget my password?
    • A: Access the password change page in Device Control to set a new password.

Specification

  • Model A320
  • Size 16082198.5mm
  • Bottle 400ml
  • Input 12V 1A
  • Power 5W
  • Coverage 160㎡/480m³/16950ft³
  • N.W. 0.74kg
  • Material Plastic

What In The Box

GuangDong-A320-Aroma-Diffuser-FIG-3

Overview

GuangDong-A320-Aroma-Diffuser-FIG-4 GuangDong-A320-Aroma-Diffuser-FIG-5

Bluetooth instruction

Where to get the app:

  • Please search for“ Scent Marketing” in Google play or APP store.

Note: Make sure that the location function of Bluetooth and mobile phone is enabled.

GuangDong-A320-Aroma-Diffuser-FIG-6

  1. Open the scent marketing app and select Bluetooth.
  2. Select your device.
  3. Enter the default password 8888 and press Login.GuangDong-A320-Aroma-Diffuser-FIG-7
  4. On the Device Control page; You can change your device name and label information of your scent diffuser.
    • NOTE: Press the “Save” button at the top right corner of the screen after each change.
  5. Different schedules by pressing the” + ” button. To delete a schedule, swipe left.
  6. Press the toggle button to turn on/off any schedule.
  7. On the “Working period setting” page, Set the hours of the day you want your diffuser to run by scrolling the “Start working time” and” Stop working time”.
  8. Select the days of the week you want your diffuser to run (all days are pre-selected).
  9. Press ” +” or ” -” to increase or decrease the preset intensity grades (1-20. See chart for details.
  10. Check (√ ) the Custom box to create a custom intensity and scroll the “Spray Time” and ” Pause Time”.
  11. Press the “Save” button to update the Settings.
  12. Tap “Calibrate” to calibrate consumption. It is advised to calibrate after working for at least 10 days. Please measure the remaining oil of the bottle first before starting calibrating. Enter the current essential oil volume, then click “Confirm” to update the consumption and remaining days automatically.
  13. Change the default password by pressing on the “About ” tab, in the” Device control”.
  14. Press the “Password Change” to access the password change page.
  15. Enter a new four-digit password, then click “Confirm”.

Note: If you forget the password, please press the reset button to restore the factory setting. The factory settings password is 8888.

Installation Step

GuangDong-A320-Aroma-Diffuser-FIG-10

  1. Press down on the latch lock on the machine to open it;
  2. Take out the bottle;
  3. Twist off the atomized head, refill the bottle with essential oil, then securely screw the bottle;
  4. Align the possition and place the bottle back into the machine;
  5. Lock the machine;
  6. In order to achieve a better fragrance effect, we recommended to use the essential oil SCENTA provide. For specific ingredients, please check SCENTA website or consult customer service, Add oil no more than 400ml.

GuangDong-A320-Aroma-Diffuser-FIG-11

  1. Drill the 3 screws into wall;
  2. Hang the machine to the screws.

Note: Be sure that ceramic tile or wood surface is clean and flat before you apply the wall tape.

Concentration and consumption

Note

  1. The abova data is for reference only. If customers use essential oils with different viscosities, the oil consumption will vary;
  2. For the best diffusion effect, it’s recommended to use essential oils with a viscosity below 30mPa.s. And the optimal working temperature is 25℃.

Warning

  1. Please keep the machine vertical;
    • Tilt or lie flatly may cause oil overflow;
    • The machine efficiency may be affected.
  2. Shall not modify , disassemble or repair the machine . If any failure happens to the machine, please contact our technical personnel.
  3. Shall not damage the power cord forcibly, such as bend, yank, heavy load, clip or reprocess it; Shall not use the broken or unmatched plug with the socket.
  4. The appliance is only to be used with the recommended vaporizing medium. The use of other substances may give rise to a toxic or fire risk.

FCC STATEMENT

FCC ID+IC ID Warning

Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’ s licence-exempt RSS(s) and Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause interference.
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC & IC Radiation Exposure Statement:

  • This equipment complies with FCC and Canada radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body.
  • This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

Troubleshooting

Before asking to have the machine repaired, please try to diagnose the problemfirst following to bellow instructions.

GuangDong-A320-Aroma-Diffuser-FIG-15

Equipment Cleaning

The machine needs to be cleaned when below situations happen:

  1. You’re about to change to another kind of essential oil;
  2. The atomization volume becomes weak .

Cleaning steps:

  1. Find a clean bottle and fill it with industrial alcohol;
  2. Install this bottle to the machine and turn the machine on. Let it work for 5-10 minutes;
  3. Turn off the electric, finish the cleaning.

QR Code

If the QR code cannot be scanned, please search for “Scent Marketing” in Google play or APP store.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Guangdong User Manuals

Related Manuals