Surenoo STP0144A-128128 Series TFT LCD Panel User Manual
- June 3, 2024
- Surenoo
Table of Contents
- Surenoo STP0144A-128128 Series TFT LCD Panel
- General Description
- Features
- Mechanical Specification
- Mechanical Dimension
- Maximum Ratings
- Electrical Characteristics
- Backlight Characteristic
- Module Function Description
- Timing characteristics.
- Electro-optical Characteristics
- Reliability
- Inspection standards
- Inspection item and criteria
- Precautions for using LCD modules
- Factory
- Revision history
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Surenoo STP0144A-128128 Series TFT LCD Panel
General Description
STP0144A-128128 is a 128RGB*128 dots matrix TFT LCD module. It has a TFT panel composed of 384sources and 128gates. The LCM can be easily accessed by micro- controller.
Features
Display Mode
| Transmissive
---|---
a-TFT
Display Format| Graphic 128RGB*128 Dot-matrix
Input Data| SPI interface
Viewing Direction| 12 o’clock
Drive| ST7735S
Mechanical Specification
Item | Specifications | Unit |
---|---|---|
Dimensional outline | 29.50(W)36.50(H)2.25+/-0.1(T) |
(FPC not include)
| mm
Resolution| 128RGB128| dots
LCD Active area| 25.50 (W)26.50 (H)| mm
Pixel size| 0.20(W)*0.20(H)| mm
Mechanical Dimension
Maximum Ratings
Item | Symbol | Min | Max | Unit | Note |
---|---|---|---|---|---|
Supply voltage | V | -0.3 | 4.6 | V | |
Operating temperature | V T | -0.3 | Vcc+0.3 | V | |
Storage temperature | T OPR | -20 | 70 | ℃ | |
Storage temperature | T STR | -30 | 80 | ℃ |
Electrical Characteristics
Item| Symbol| Condition| Min.| Typ.| Max.|
Unit
---|---|---|---|---|---|---
Supply voltage| Logic| V CC| | 2.7| 2.8|
3.3| V
Input Voltage| H level| T IH| | 0.8IOVCC| |
IOVCC| V
L level| T IL| -0.3| | 0.2 IOVCC
Storage temperature
| ****
I DD
| With internal voltage generation V CC=2.8V;
T emp=25℃
| | | ****
TBD
| ****
mA
Backlight Characteristic
Item | Symbol | Min | Typical | Max | Unit |
---|---|---|---|---|---|
LED module Forward voltage | V LED | 3.0 | 3.2 | 3.4 |
V
LED module current| V LED| | 20| | mA
L/G Surface Luminance ★ 1| L S| 1800| | | Cd/m 3
LCM Surface brightness uniform ★ 2| L D| 80| | | %
- Test condition is:
- Center point on active area.
- Best Contrast.
- Uniform measure condition:
- Measure 9 point. Measure location show below;
- Uniform=(Min. brightness /Max. brightness)*100%
- Best Contrast.
Module Function Description
Pin Descriptions
PIN No. | Symbol | Description | Notes |
---|---|---|---|
1 | NC | No connection | |
2 | GND | Ground | |
3 | LED- | Cathode of Backlight | |
4 | LED+ | Anode of Backlight (3.0V-3.4V) | |
5 | GND | Ground | |
6 | /RESET | LCM Reset pin |
7
|
A0
| Register select pin
RS=’1’: Display data.(RS=’1’) RS=’0’: Command data.(RS=’0’:)
|
8| SDA| Serial data input / output.|
9| SCK| Serial clock pin.|
10| VCC| Power supply for Analog(2.8V-3.3V)|
11| IOVCC| Power supply for interface(1.8V-3.3V)|
12| CS| Chip select pin (“Low” enable)|
13| GND| Ground|
14| NC| No connection|
Timing characteristics.
Serial Interface Characteristics (4-line Serial)
Electro-optical Characteristics
Item| Symbol| Conditions| Temp| Min.| Typ.|
Max.| Unit| Note
---|---|---|---|---|---|---|---|---
Response Time| TR| θ=φ =0| 25℃| | TBD| TBD| msec| NOTE2
TF| | TBD| TBD|
Viewing Angle Range| φ=00(6”)| φ=900(3”)| φ=1800(12”)| φ=2700(9”)| NOTE3
θ(25℃) CR≥10| TBD| TBD| TBD| TBD| NOTE3
The above “viewing angle” is the measuring position with the largest contrast ratio. Not for good image quality. Viewing direction for good image quality is 12 O’clock.
- For panel only
- Electro-Optical Characteristics Test Method
Note2. Definition of Optical Response Time:
Note3. Definition of Viewing Angle θ and φ:
Note4. Definition of Contrast ratio (CR):
Reliability
Mtbf
The LCD module shall be designed to meet a minimum MTBF value of 50000 hours with normal
Test condition
NO. | ITEM | CONDITION | CRITERION |
---|---|---|---|
1 | High Temperature Non-Operating Test | 80℃*240Hrs | o No Defect Of Operational |
2 | Low Temperature Non-Operating Test | -30℃*240Hrs | Function In Room |
Temperature
3| High Temperature/Humidity Non Operating Test| 60℃90%RH240Hrs| Are
Allowable
4| High Temperature Operating Test| 70℃240Hrs| o IDD of LCM in Pre-and
5| Low Temperature Operating Test| -20℃240Hrs| Post-Test Should Follow
6| Thermal Shock Test| -20 ℃ (30Min) e70 ℃(30Min)| Specification
*10CYCLES|
Notes:
- Judgments should be made after exposure in room temperature for two hours.
- The distill water is used for the high temperature/humidity test.
- The sample above is individually for every reliability tests condition.
Inspection standards
AQL(Acceptable Quality Level
AQL of major and minor defect.
MAJOR DEFECT | MINOR DEFECT | |
---|---|---|
AQL | 0.65 | 1.5 |
Basic conditions for inspection
The LCM face to us, in normal environment, the lux is 1000±200.(Darkroom’s
lux: 100±50),About an angle of incidence 30,a distance of 30 cm with an angle
of 45 degree to check the products without uncovering the film!
(As shown below)
Inspection item and criteria
Visual inspection criterion in immobility
Glass defect
LCD appearance defect(View area)
FPC
Black tape &Mara tape Silicon and Taffy glue
Electrical criteria
Precautions for using LCD modules
Safety
- Do mot swallow any liquid crystal ,even if there is no proof that liquid crystal is poisonous.
- If the LCD panel breaks, be careful not to get liquid crystal to touch your skin.
- If skin is exposed to liquid crystal, wash the area thoroughly with alcohol or soap.
Srorang Conditions
- Store the panel or module in a dark place where the temperature is 23±5℃and the humidity is below 45 ±20%RH.
- Store in anti-static electricity container.
- Store in clean environment, free from dust, active gas, and solvent.
- Do not place the module near organics solvents or corrosive gases.
- Do not crush, shake, or jolt the module.
Handling Precautions
- Avoid static electricity, which can damage the CMOS LSI.
- The polarizing plate of the display is very fragile, please handle if very carefully.
- Do not give external shock.
- DO mot apply excessive force on the surface.
- Bo not wipe the polarizing plate with a dry cloth, as it may easily scratch the surface of plate.
- Do not use ketonics solvent & Aromatic solvent, use with a soft cloth soaked with a cleaning naphtha solvent.
- Do not operate it above the absolute maximum rating.
- Do not remove the panel or frame from the module.
Warranty
The period is within twelve months since the date of shipping out under normal
using and storage conditions.
Factory
FACTORY NAME:
FACTORY ADDRESS:
FACTORY PHONE:
Revision history
Version | Revise record | Date |
---|---|---|
v0.0 | Original version | 2014-06-16 |
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>