Product Specifications

  • Product Name: Vortex Slimline Concealed Cistern with Air Gap Technology
  • Model Number : VOR790
  • Care & Safety: Suitable for solid stone/brick walls; Water pressure range: 0.1 – 10 bar
  • Flush Volume: Full – 6L, Reduced – 3L
  • Nominal Water Level: 198mm
  • Fitting Dimensions: 135 – 370mm

Product Usage Instructions

General Installation Guidelines

  1. Ensure wall plugs are suitable for the wall material.
  2. If fixing to a stud wall, reinforce it adequately.
  3. Installation must be done by a qualified plumber or installer.
  4. Test for leaks before enclosing the cistern.
  5. Do not use caustic chemical substances in the cistern.

Inlet Valve Adjustments and Maintenance

Adjust the fill valve to control the water level. Clean aerators by removing the cap and using a screwdriver to push them out.

Cleaning and Maintenance

If flow rate slows down, clean the diaphragm. Refer to the user manual for disassembly and cleaning instructions.

Installation Steps

  1. Use masking tape between drill bit and tiles to prevent wandering.
  2. Mark fixing points accurately.
  3. Ensure wall fixings are appropriate for the wall material.
  4. Secure the bracket in place properly.

FAQs

  • Q: Can this cistern be used with wall-hung pans?
    • A : This cistern is not suitable for use with wall-hung pans without a suitable supporting frame.
  • Q: What is the water pressure range suitable for this cistern?
    • A : The cistern fittings are suitable for water pressure ranging from 0.1 to 10 bar.
  • Q: How can I adjust the water level in the cistern?
    • A : By adjusting the fill valve, you can increase or decrease the water level accordingly.

Please read it completely first before commencing and retain for future reference

This product must be installed by a qualified fitter or plumber in accordance with and meet the requirements of Water Supply (Water Fittings) Regulations 1999, the Water Supply (Water Fittings) (Scotland) Byelaws 2014 and the Water Supply (Water Fittings) Regulations (Northern Ireland) 2009

Parts included

VORTEX-VOR790-Slimline-Concealed-Cistern-FIG \(1\)

  1. Cistern
  2. EPS Ja cket
  3. Seal – SP12168
  4. Flush Bend Nut – SP12168
  5. Flush Bend – SP12167
  6. Pan Seal Cone – SP12170
  7. Bottom Entry Fill Valve – SP19745
  8. Stem Sealing Washer – SP19757
  9. Inlet Valve Diaphragm – SP19756
  10. 2 x Attaching Screws – SP12163
  11. Attachment Plate – SP12163
  12. Cistern Cover – SP12164
  13. Pneumatic Push-button – SP12169
  14. Air Hoses – SP17421
  15. Flush Valve – SP12166
  16. Flush Valve Flapper Seal – SP12551
  17. Cistern Fixing Screw – SP12163

Fitting dimensions

VORTEX-VOR790-Slimline-Concealed-Cistern-FIG \(2\)

Installation

Installation of the cistern

VORTEX-VOR790-Slimline-Concealed-Cistern-FIG \(3\)

VORTEX-VOR790-Slimline-Concealed-Cistern-FIG \(4\)

tips

It is recommended that the flush bend be adequately braced against the wall using an appropriate pipe bracket or wooden packing. Ensure there is no tension/stress on the connection to the tank as this could cause the fittings to leak. VORTEX-VOR790-Slimline-Concealed-Cistern-FIG
\(5\)

note

Check valve not included

Connect the water supply to the cistern using an approved double-check valve to fluid category 3 in addition to an accessible service or isolation valve.

important

This product is to be installed in a concealed location only

VORTEX-VOR790-Slimline-Concealed-Cistern-FIG \(6\)

Installation with a front access panel

VORTEX-VOR790-Slimline-Concealed-Cistern-FIG \(7\)

Installation with a top access panel

VORTEX-VOR790-Slimline-Concealed-Cistern-FIG \(8\)

Installation of pneumatic push-button

VORTEX-VOR790-Slimline-Concealed-Cistern-FIG \(8\)

Fixing the toilet

VORTEX-VOR790-Slimline-Concealed-Cistern-FIG \(10\)

Adjusting the flush volume

VORTEX-VOR790-Slimline-Concealed-Cistern-FIG \(11\)

Inlet Valve Adjustments and Maintenance

By adjusting the fill valve the water level can either be increased or decreased accordingly

VORTEX-VOR790-Slimline-Concealed-Cistern-FIG \(12\)

OPERATIONAL INSTRUCTIONS

VORTEX-VOR790-Slimline-Concealed-Cistern-FIG \(13\)

General Care & Safety 

Wall plugs supplied are ONLY suitable for solid stone/brick walls. They are not suitable for use in aerated blocks or similar. If fixing to a stud wall, sufficient extra internal reinforcements must be made to the wall. Screws must locate into suitably reinforced studs and noggins.
Take care using power tools – The use of a residual current device (RCD) is recommended. Beware of hidden cables or pipes when drilling.
This product can be dangerous if installed incorrectly. This product must be installed by a qualified plumber or installer. It is the installer’s responsibility to check that the fixings are suitable for the installation in hand.
Cistern fittings are suitable for Water pressure: 0.1 – 10 bar. Do not add caustic chemical substances (e.g. containing chlorine compounds or similar) into the cistern. These can damage the valve components and cause failure. \

Before starting to enclose the cistern, the system must be first tested for leaks before 2nd fix commences. Temporarily fix the back to wall pan in place and make connections. Turn the water supply on and flush the pan to check for leaks. This is particularly important to do prior to tiling for fully tiled in installations

This cistern is not suitable for use with wall-hung pans without the use of a suitable supporting frame.

Troubleshooting Guide

Please retain for future reference

How to Access your cistern

VORTEX-VOR790-Slimline-Concealed-Cistern-FIG
\(15\)VORTEX-VOR790-Slimline-Concealed-
Cistern-FIG \(16\)

VORTEX-VOR790-Slimline-Concealed-Cistern-FIG \(17\)

VORTEX-VOR790-Slimline-Concealed-Cistern-FIG \(18\) VORTEX-VOR790-Slimline-Concealed-Cistern-FIG
\(19\)

Brought to you by the Roper Rhodes Group
Brassmill Lane Trading Estate
Bath

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

VORTEX User Manuals

Related Manuals