AMP25BDC Motor Instruction Manual
- June 12, 2024
- AMP
Table of Contents
AMP25BDC Motor
Fields of Application
-
Roller
-
Sheer
-
Banded
-
Roman
-
Narrow
Specifications
Working temperature: -10º C ~ +50º C Radio Frequency: 433.925 MHz
Input Voltage: USB 5V 1A / USB 5V 2A Maximum Running Time: 6 minutes
The motor is suitable for motorization of roller shades, sheer shades, roman shades, and revolve shades.
Model| Rated Torque (N.m)| Rated Speed (RPM)| Rated Power
(W)
---|---|---|---
25BDC – 1.1/28| 1.1| 28| 12
Attention
Never drop, knock, drill or submerge the motor. Keep the power cable in the proper position as shown below.
Read all safety instructions before installation.
Incorrect installation can lead to serious injury and will void manufacturer’s
liability and warranty.
Safety Instructions
- Do not expose motor to humid, damp, or extreme temperature conditions.
- Do not drill into motor.
- Do not cut the antenna. Keep it clear from metal objects.
- Do not allow children to play with this device.
- If the power cable or connector is damaged, do not use.
- Ensure the correct crown and drive adaptor are used.
- Ensure the power cable and aerial is clear and protected from moving parts.
- Cable routed through walls should be properly isolated.
- Motor is to be mounted in horizontal position only.
- Before installation, remove unnecessary cords and disable equipment not needed for powered operation.
- Installation and programming should be performed by a qualified professional. Use or modification outside the scope of these instructions may void warranty
Charging Instructions
This motor connects with an external Li-ion battery pack with integrated charge management.
Max power input for recharging: 5V 2A.
Before first use please charge motor for 6 hours using a 5V charger.
During operation, if the voltage is detected to be too low, the battery stops running and needs to be recharged
Rechargeable Battery
-
Solid Red: Charging in process
-
Solid Green: Battery has finished charging
P1 Button Instructions
➀ Test Motor
Happening as you press for 1 second| when released
| Motor Response: Wakes & Runs
➁ Activate Pairing Mode
Happening as you press for 2 seconds| when released
|
➂ Sleep Mode
Happening as you press for 6 seconds| when released
|
➃ Reverse Direction
Happening as you press for 10 seconds| when released
|
➄ Reset To Factory Settings
Happening as you press for 14 seconds| when released
|
Declarations
U.S. Radio Frequency FCC Compliance
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference
that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
ISED RSS Warning:
This device complies with Innovation, Science and Economic Development Canada
licence-exempt RSS standard(s). Operation is subject to the following two
conditions: (1) this device may not cause interference, and (2) this device
must accept any interference, including interference that may cause undesired
operation of the device.
Quick Index
Settings | Steps |
---|---|
1 | Pairing |
2 | Switch Rotating Direction |
3 | Setting Upper & Lower Limits |
Stop (hold down for 2s)
Lower Limit: Down (hold down for 2s) > Down + Stop (hold down for 2s)
4| Add / Remove Favorite Position| P2 > Stop > Stop
5| Roller Mode & Sheer Mode Switch| Up + Down (hold down for 5s) > Stop
6| Adjust Limits| Upper Limit: Up + Stop (hold down for 5s) > Up or Down > Up
- Stop (hold down for 2s)
Lower Limit: Down + Stop (hold down for 5s) > Up or Down > Down + Stop (hold down for 2s)
7| Pair / Unpair Additional Emitter| P2 (existing) > P2 (existing) > P2 (new)
8| Speed Regulation| Acceleration: P2 > Up > Up
Deceleration: P2 > Down > Down
Troubleshooting
Issues | Possible Causes | Solution |
---|---|---|
The motor is not responding | External battery pack is depleted | Recharge with |
compatible AC adaptor and check
connection and positioning of solar PV panel
Insufficient charging from Solar PV Panel| Check connection and orientation of
solar PV panel
Remote control battery is discharged| Replace battery
Battery is inserted incorrectly into
remote control
| Check battery polarity
Radio interference / shielding| Ensure remote control and the antenna on the
motor are positioned away from metal objects
Receiver is far away from Remote Control| Move remote control to a closer
position
Power failure| Check power supply to motor is connected and active
Incorrect wiring| Check that wiring is connected correctly (refer to motor
installation instructions)
Motor beeps 10 times when in use| Battery voltage is low / PV (solar panel
issue)| Recharge with AC adapter or check connection and positioning of solar
PV panel
Cannot program a single motor (multiple motors respond)| Multiple motors are
paired to the same channel.| Always reserve an individual channel for
programming functions
SYSTEM BEST PRACTICE – Provide an extra 15 channel remote in your multi-motor
projects that provides individual control for each motor for programming
purposes
Place all other motors into sleep mode (ref to P1 button instructions)
Do not dispose of in general waste.
Please recycle batteries and damaged electrical products appropriately
Please scan QR code to see more AMP™ product information
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>