KERBL 34546 LED Moisture-Proof Lamp Instruction Manual

June 3, 2024
KERBL

KERBL LOGO Operating instructions
LED Moisture-proof Lamp
(item no. 34546, item no. 34547)

34546 LED Moisture-Proof Lamp

KERBL 34546 LED Moisture Proof Lamp

General

Please keep these operating instructions in a safe place for later use.
These operating instructions comprise instructions for use and safety information. Please read the instructions carefully and note the regulations and relevant information before putting the lamp into operation. Please keep these operating instructions in a safe place for later use!
Correct use
The lamp is used for stationary installation on sufficient load-bearing ceiling or wall structures.
Installation is done outside of arm‘s reach. The lamp should ensure the required level of lighting.
Not intended for use in places with deposition of conductive dust. Any other use shall be deemed incorrect. Improper use and tampering with the lamp will void warranty and liability claims.

Safety instructions

CAUTION!
Risk of physical injury and material damage if used incorrectly!

  • Installation should be carried out by a qualified electrical technician.
  • Ensure the light is disconnected from the mains voltage before commencing work.
  • Install and store the light out of the reach of children.
  • Do not open the light, especially in case of a defect. If required, contact the manufacturer.
  • Only use original spare parts.
  • Do not look directly into the light beam.
  • Do not use chemicals for cleaning.
  • This light is not suitable for accent lighting.
  • This light cannot be dimmed.
  • Do not operate the lamp in environments where flammable gases, vapors, or dust may be present.
  • Before each use, check that the lamp is in good condition. Do not operate the lamp if a component is defective.
  • National and international safety, health, and occupational safety regulations must be observed and complied with.
  • When installing the mains supply, the appropriate standards, guidelines, and requirements must be met.
  • The consistency of the protective conductor up to the main ground of the building must be measured using appropriate means and in line with the applicable installation regulations on every lamp.
  • The degree of protection against the ingression of water may possibly be interrupted at the connection point Take suitable precautions to ensure that a hazard does not result from water ingression at the plug or connection box. A connection box must have the protection rating IP65.
  • The luminaire connection cable cannot be replaced. If the connection cable is damaged, the luminaire must be scrapped.
  • Only use screwless terminals to connect the connection cable.
  • To connect the connection cable, use three separate terminals in a suitable connection box (IP65).
  • Use sufficiently viable screws for fastening the ceiling structure.

Installation
Mount the light to the ceiling or wall using the supplied mounting plates and fixing materials suitable for the base.
Electrical connection
L: Brown, N: Blue, PE: yellow/green

Technical data

Performance / luminous flux| No. 34546: 40 W / 5.000 lumens
No. 34547: 55 W / 6.500 lumens
---|---
Light angle| 130°
LED type| SMD 2835
Service life| Approx. 50.000 h
Input voltage| 220 – 240 V / 50 – 60 Hz
Working temperature| – 40 °C till + 50 °C
Color temperature| 6000 K
Color rendering (CRI)| Ra > 80
Safety class| IP 67
cos φ| 0,95

Electronic scrap
Disposing of this device after its service life is the responsibility of the operator. Please consult the valid national regulations. The device must not be disposed of in the household waste. In accordance with the stipulations of the EU Directive on the Disposal of Electrical and Electronic Devices, the device can be disposed of free of charge at the local waste collection or recycling center. Alternatively, it can be returned to retailers who offer a collection service. Proper disposal helps to ensure environmental protection and prevents any adverse effects on human health and the environment.

KERBL 34546 LED Moisture Proof Lamp - ICON

CE-/UKCA-conformity declaration
Albert KERBL GmbH hereby declares that the product/device described in these instructions complies with the fundamental requirements and other relevant stipulations and regulations. The CE-/UCKAmark confirms compliance with the Directives of the European Union or the relevant UK legislation.

Albert Kerbl GmbH
Felizenzell 9
84428 Buchbach, Germany
Tel. +49 8086 933 – 100
Fax +49 8086 933 – 500
www.kerbl.de| Kerbl Austria Handels GmbH
Wirtschaftspark 1
9130 Poggersdorf, Austria
Tel. +43 4224 81555
Fax. +43 4224 81555-629
www.kerbl-austria.at
---|---
Kerbl France Sarl
3 rue Henri Rouby, B.P 46 Soultz
68501 Guebwiller Cedex, France
Tel. : +33 3 89 62 15 00
Fax : +33 3 89 83 04 46
www.kerbl-france.com| Kerbl UK Ltd
Lands End Way
Oakham, Rutland
LE15 6RF, UK
Tel: (44) 01572 722558
www.kerbl.co.uk

Documents / Resources

| KERBL 34546 LED Moisture-Proof Lamp [pdf] Instruction Manual
34546 LED Moisture-Proof Lamp, 34546, LED Moisture-Proof Lamp, Moisture-Proof Lamp, Lamp
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals