MEAN WELL LOP-400 Series 400W 5×3 Inch Low Profile Open Frame Power Supply Owner’s Manual
- June 1, 2024
- MEAN WELL
Table of Contents
400W 5″×3″ Low Profile Open
Frame Power Supply
LOP-40 0 s e r i es
https://www.meanwell.com/Upload/PDF/PCB_EN.pdf
Features
-
MEAN WELL Patent Number: ZL 202223277512.1
-
5″x3″ compact size with low profile (27.5mm)
-
80~264Vac input with PFC, No load power consumption<0.5W
-
Global certificates in multi-fields
(ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1/-2-16) -
150%peak load @ 3s + 250W convection, 400W with FAN 23CFM forced-cooled * Suitable for Class I or Class IT installations
-
Over voltage category Il (OVC III) * -40 ~ +80°C wide range operation temperature
-
High efficiency up to 95%
-
Protections: Short circuit / Overload / Over voltage / Over temperature
-
Extremely low leakage current, 2 x MOPP, suitable for BF medical applications
-
Operating altitude up to 5000 meters
-
Built-in 12V/0.5A for external FAN * Built-in Remote sense
-
3 years warranty
Applications
- Industrial automation machinery/ control system
- Security system
- Mechanical and electrical equipment
- Electronic instruments, equipments or apparatus
- Network equipment
- Telecom devices
- Power sourcing equipment of PoE
- Home automation
- Medical devices
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
The LOP-400 is a 400W highly reliable, energy-efficient, low-profile open
frame type power supply. With a high power density of 24.6W/in® within the
standard size of 5″ x 3″, it features a universal input voltage range of
80~264VAC, making it suitable for global applications. The series offers a
comprehensive selection of standard voltages, including
12V/15V/18V/24V/27V/36V/48V/54V, and comes in a complete range of models.
The main features of the LOP-400 include: low standby power (<0.5W), high
efficiency (up to 95%), capable of providing 250W under natural air cooling
and 400W with an additional fan. It has a 150% @ 3 seconds overload capacity,
a wide operating temperature range of -40 to +80°C, compliance with OVCIII,
suitable for Class | (with FG) or Class Il (without FG) systems. The product
has obtained multiple safety certifications, including
62368-1/60601-1/61558-1/60335-1, and is designed to meet 2xMOPP and extremely
low touch leakage current <70 A, making it suitable for BF class medical
devices. With high product safety and excellent EMC performance, it is
versatile and applicable in various fields such as ITE, medical, industrial
control, home automation and more. Itis a cost-effective slim open frame type
power supply.
Model Encoding
SPECIFICATION
MODEL| LOP-400-12| LOP-400-15| LOP-400-18|
LOP-400-24| LOP-400-27| LOP-400-36| LOP-400-48|
LOP-400-54
---|---|---|---|---|---|---|---|---
OUTPUT
| DC VOLTAGE| 12V| 15V| 18V| 24V| 27V| 36V| 48V| 54V
CURRENT
| Peak(3sec.)| 50A| 40A| 33.3A| 25A| 22.2A| 16.7A| 12.5A| 11.1A
23CF
M|
33.3A| 26.7A| 22.2A| 16.7A| 14.9A| 11.2A| 8.4A| 7.5A
Convection| 20.8A| 16.7A| 13.9A| 10.5A| 9.3A| 7.1A| 5.3A| 4.75A
RATED POWER
| Peak(3sec.)| 600W| 600W| 599.4W| 600W| 599.4W| 601.2W| 600W| 599.4W
23CF
M|
399.6W| 400.5W| 399.6W| 400.8W| 402.3W| 403.2W| 403.2W| 405W
Convection| 249.6W| 250.5W| 250.2W| 252W| 251.1W| 255.6W| 254.4W| 256.5W
RIPPLE & NOISE (max.) Note.2| 120mVp-p| 150mVp-p| 180mVp-p|
200mVp-p| 200mVp-p| 250mVp-p| 250mVp-p| 250mVp-p
VOLTAGE ADJ. RANGE
(MAIN OUTPUT)
| 11.4~12.6V| 14.3~15.8V| 17.1~18.9V| 22.8~25.2V| 25.6 ~ 28.4V| 34.2 ~37.8V|
45.6 ~50.4V| 52 ~58V
VOLTAGE TOLERANCE Note.3| ±3.0%| ±3.0%| ±3.0%| ±2.0%| ±1.0%| ±1.0%|
±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
SETUP, RISE TIME| 1000ms, 30ms/230VAC 1500ms, 30ms/115VAC at
full load
HOLD UP TIME (Typ.)| 30ms@250W load , 16ms@400W load
INPUT
| VOLTAGE RANGE Note.4| 80 ~ 264VAC 113 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR| PF>0.95/230VAC PF>0.98/115VAC at full load
EFFICIENCY (Typ.)| 94%| 94.5%| 95%| 94.5%| 95%| 95%| 95%| 95%
AC CURRENT (Typ.)| 4.2A/115VAC 2.1A/230VAC
INRUSH CURRENT (Typ.)| COLD START 40A/115VAC 80A/230VAC
LEAKAGE CURRENT| Earth leakage current < 500μA(rms) @ 264VAC , touch
current < 70μA(rms) @ 264VAC
PROTECTION
| ****
OVERLOAD
| 105 ~ 150% rated output power, Protection type : Hiccup after 3 sec, recovers automatically after fault condition is removed
OVER VOLTAGE
| 13.2 ~ 15.6V| 16.5 ~ 19.5V| 19.8 ~ 23.4V| 26.4 ~ 31.2V| 29.7 ~ 35.1V| 39.6
~ 46.8V| 52.8 ~ 62.4V| 59.4 ~ 67.5V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Protection type : Shut down o/p voltage, recovers
automatically after temperature goes down or re-power on to recover
FUNCTION
| ****
EXTERNAL FAN SUPPLY
| 12V@0.5A for driving a fan
(23CFM)
/ 12V@0.2A for without fan ; Tolerance -15% ~+15% at main
output 20% rated current
REMOTE SENSE| The remote sensing compensates voltage drop on the load
wiring up to 0.5V
POWER GOOD / POWER FAIL
(optional)
| 500ms>PG>10ms ; The TTL signal goes high with 10ms to 500ms delay after power set up ;
The TTL signal goes low at least 1ms before Vo below 90% of rated value ; TTL(0 ~ 1V), TTH(2 ~ 5V)
ENVIRONMENT
| WORKING TEMP.| -40 ~ +80℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & **EMC**
(Note 5)
| ****
SAFETY STANDARDS
| CB IEC62368-1, IEC60335-1, IEC61558-1/-2-16, IEC60601-1;
TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16, BS
EN/EN60601-1(3.2 Version); UL UL62368-1, ANSI / AAMI ES60601-1(3.2 Version) ;
CCC GB4943.1 ; RCM AS/NZS 61558-1/-2-16; EAC TPTC 004 approved.
---|---|---
ISOLATION LEVEL| Primary-Secondary: 2xMOPP, Primary-
Earth:1xMOPP, Secondary-Earth:1xMOPP
**OVER VOLTAGE CATEGORY| IEC/EN 61558-1/-2-16(OVC Ⅲ, altitude up
to 2000M ) IEC/EN/UL 62368-1 (OVC Ⅱ, altitude up to 5000M ) IEC/EN 60335-1
(OVC Ⅱ, altitude up to 5000M ) IEC/EN 60601-1 (OVC Ⅱ, altitude up to 4000M )
PROTECTIVE EXTRA- LOW VOLTAGE| IEC/EN61558-2-16 (SELV, 12~48V )
IEC/EN/UL 62368-1 (SELV / ES1, 12~48V )
WITHSTAND VOLTAGE| I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
ISOLATION ****RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC
/ 25℃/ 70% RH
****EMC EMISSION| Parameter| Standard| Test Level / Note
** Conducted & Radiated| BS EN/EN55032(CISPR32) BS EN/EN55011(CISPR11)|
ClassⅠ: Class B , Class Ⅱ: Class A
BS EN/EN55014(CISPR32)| ClassⅠ: Class B
Harmonic Current| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| ——-
EMC IMMUNITY
| BS EN/EN55035,BS EN/EN61000-6-2
Parameter| Standard| Test Level /Note
ESD| BS EN/EN61000-4-2| Level 4, 15KV air ; Level 4, 8KV contact
Radiated Susceptibility| BS EN/EN61000-4-3| Level 3, 10V/m( 80MHz~2.7GHz )
Table 9, 9~28V/m( 385MHz~5.78GHz )
EFT/Burest| BS EN/EN61000-4-4| Level 3, 2KV
Surge| BS EN/EN61000-4-5| Level 4, 4KV/Line-FG ; 2KV/Line-Line
Conducted| BS EN/EN61000-4-6| Level 3, 10V
Magnetic Field| BS EN/EN61000-4-8| Level 4, 30A/m
Voltage Dips and interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 100%
dip 1 periods, 30% dip 25 periods,
>95% interruptions 250 periods
OTHERS
| MTBF| 1696.4K hrs min. Telcordia SR-332 (Bellcore) ; 231.2K
hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 12776.227.5mm (LWH)
PACKING| 0.39Kg; 24pcs/11.5Kg/1.0CUFT
NOTE
| 1. All parameters NOT specially mentioned are measured at 230VAG input,
rated load and 25’Cof ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted
pair-wire terminated with a 0.1.F & 47,F parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load
regulation.
4. Derating may be needed under low input voltages. Please check the derating
curve for more details.
The power supply is considered a component which will be installed into a
final equipment. All the EMC tests are been executed by mounting the unit on a
360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-
confirmed that it still meets EMC directives. For guidance on how to perform
these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on https://iwww.meanwell.com/Upload/PDF/EMI_statement_en.pdf)
3% Product Liability Disclaimer : For detailed information, please refer to
https://www.meanwell.conv/serviceDisclaimer.aspx
Block Diagram
Derating Curve
Cooling | Max. Output Power |
---|---|
Free air convection | 250W |
Force-cooled with external Fan | 400W |
Output Derating VS Input Voltage
Mechanical Specification
AC Input Connector (CN1) : JST B3P-VH or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
---|---|---|---|
1 | AC/L | JST VHR |
or equivalent
| JST SVH-21T-P1.1 or equivalent
2| No Pin
3| AC/N
DC Output Connector
Assignment | Output Terminals |
---|---|
-V | M3.5 Pan HD screw in 2 positions Torque to 8 lbs-in(90cNm)max. |
+V
FAN Connector(CN2) : TKP 8812-2 or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
---|---|---|---|
1 | DC COM | TKP 2502 | |
or equivalent | TKP 8811 |
or equivalent
2| +12Vaux
Function Connector(CN3): TKP DH2I-2X2 or equivalent
Note:
Class T System: Mounting holes marked with -L- have to be connected to safety
earth.
Class IT System: Unnecessary to connect with safety earth.
Hs1.HS2 can not be shorted
Installation Manual
Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.htmi
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>