Product Specifications
General Data
- Power supply: 10-30 Vdc, 90-264 Vac (50-60Hz)
- Max Power consumption: 2.5 W max
- Max Isolation: 3.500 Vac
- Installation category: 300 V CAT III, 600 V CAT III
- Front protection degree: IP20
- Accuracy class: 0.5
- Operating temperature: -25°C to +70°C
- Storage temperature: -40°C to +85°C
- Humidity: 0 to 95% non-condensing
- Dimension: 90 x 107 x 32 mm
- Weight: 170 g
- Housing: PC/ABS self-extinguishing UL94-V0, black color
- Approvals: CE, UKCA
Communication
- Ethernet comm. Ports: 2 Ethernet ports 100BaseT
- Speed: 100 Mbps
- Supported Protocol: Ethernet/IP
- Connectivity: Daisy Chain
- LAN Fault By-Pass: Yes
Measurement and I/O Channels
- Number of channels: 1 measurement input, 2DI, 2DO, 1AO
- Measurement Input:
- PHASE VOLTAGE: Minimum voltage 5 V (F.S. 150 Vac); 20 V (F.S. 600 Vac)
- PHASE CURRENT: Voltage input (mV) for CT with voltage or Rogowski output: up to 250 mV
- Analog Output: VOLTAGE 0-10 Vdc, CURRENT (active/passive) 0-20, 4-20 mA
- Digital Inputs: 2 digital inputs activated with voltage from 12 to 24V
- Digital Outputs: 2 digital outputs, range Imax = 50 mA Vmax = 28V
Special Functions
- DAISY-CHAIN CONNECTION: Reduced wiring, minimum infrastructure costs, and installation flexibility
- FAULT BYPASS: Maintaining the Ethernet chain connection even in the event of a module failure
Order Codes
Code | Description |
---|---|
R203-2-L-E | Three-phase power meter, 2xETH, 24 Vdc, Ethernet/IP |
R203-2-H-E | Three-phase power meter, 2xETH, 90-264 Vac, Ethernet/IP |
Product Usage Instructions
Installation and Setup:
- Ensure proper power supply within the specified range.
- Mount the power meter on a suitable surface using the provided DIN rail or screws.
- Connect the necessary voltage and current inputs as per your electrical configuration.
- Connect the Ethernet ports for communication.
Data Monitoring and Analysis:
Access the web server for connection diagnostics and firmware updates.
Configure the settings for measurement channels and I/O according to your
requirements.
Maintenance :
Regularly check the device for any signs of damage or malfunction. Keep the
device clean and free from dust accumulation.
Frequently Asked Questions (FAQ)
-
Q: What is the maximum power consumption of the R203-E power meter?
A: The maximum power consumption is 2.5 W. -
Q: What are the supported communication protocols?
A: The R203-E power meter supports Ethernet/IP protocol.
R203-E
3-PHASE ENERGY POWER METER
WITH 2 ETHERNET PORTS AND ETHERNET/IP PROTOCOL
The three-phase energy power meter R203-E accepts current measurement inputs for CTs with current/voltage output, TVs and Rogowski sensors (with voltage output up to 333 mV), with single-phase, three-phase 3/4-wire, Aron and Ethernet/IP protocol support. Thanks to the Ethernet interface, a daisy chain connection to the next Ethernet device can be realized, avoiding expensive industrial switches and simplifying wiring. The R203-E returns single-phase and three-phase values of the main electrical quantities: voltage, current, active, reactive, apparent power, frequency, period, power factor and harmonics. The configurable analog output in voltage or current al-lows the analyzer to also be used as a measurement converter. The R203-E also offers measurement and recording of harmonics in voltage/current up to 55th order with THD (total harmonic distortion) calculation.
Highlights
- Universal input in voltage, current, TA with A/mV output, TV, Rogowski sensors
- Optimized display on Surprise Smart Display
- Full scale input: 600 Vac (voltage), 5A (TA), TA with voltage output, Rogowski (250 mV)
- Output: mA/V
- Accuracy Class: 0.2% for voltage/current; 0.5% for power
- Operating temperature: -25..+75°C
- Ethernet Daisy Chain connection
- Configuration: EDS, Web Server
R203-E | 3-PHASE POWER METER WITH ETHERNET/IP
3-PHASE POWER METER – ETHERNET/IP
| R203-2-L-E| R203-2-H- E
|
Three-phase power meter, 2xETH, 10-30 Vdc, Ethernet/IP
| Three-phase power meter, 2xETH, 90-264 Vdc, Ethernet/IP
GENERAL DATA
Power supply| 10..30 Vdc| 90-264 Vac (50-60Hz)
Max Power consumption| 2.5 W max
Max Isolation| 3.500 Vac
Installation category| 300 V CAT III| 600 V CAT III
Insertion mode| Single-phase, three-phase 3/4-wire, Aron
Front protection degree| IP20
Accuracy class| 0,5
Mounting| IEC EN60715 35mm DIN rail, wall or panel mounted wiyh screws
Connections| Screw terminals
Operating temperature| -25…+65°C
Storage temperature| -30…+85°C
Humidity| 30% ÷ 90% non condensing
Dimension| 90 x 107 x 32 mm
Weight| 170 g
Housing| PC/ABS self-extinguishing UL94-V0, black color
Approvals| CE, UKCA
MEASUREMENT AND CALCULATION TIMES
Sampling times| 8.000 sps (for voltage/current channels)
Bus scan time| >2 ms
RMS value settling time| 580..700 ms
Harmonic tuning time| 30s
PROGRAMMING
Web Server| Connection diagnostics, firmware update
GSD/GSDML/ EDS| Configuration, project design and I/O
COMMUNICATION
Ethernet comm.|
Ports| 2 porte Ethernet 100BaseT
Speed| 100 Mbps
Supported Protocol| Ethernet/IP
Connectivity|
Daisy Chain| Yes
LAN Fault By-Pass| Yes
MEASUREMENT AND I/O CHANNELS
Number of channels| 1 ingresso di misura, 2DI, 2DO, 1AO
Measurement Input| PHASE VOLTAGE
| Up to 600 Vac, frequency 45 ÷ 65Hz
| Minimum voltage 5 V ( F.S. 150 Vac); 20 V (F.S. 600 Vac)
| TV with output up to 600 Vac to neutral
| PHASE CURRENT
| Current input for CT: 1 ÷ 5A full scale
| Voltage input (mV) for CT with voltage or Rogowski output: up to 250 mV
| Main frequency: 50 to 60Hz
| Accuracy: voltmeter : 0.2 %; amperometer: 0.2%, wattmeter: 0.5%
Analog Output| VOLTAGE 0..10 Vdc, min load resistance 2kΩ CURRENT
(active/passive): 0..20, 4..20 mA, max load resistance 500Ω
Transmission error: 0.1 % of maximum range
Thermal drift: 100 ppm/K
Digital Inputs| 2 digital inputs activated with voltage from 12 to
24V
Digital Outputs| 2 digital outputs, range Imax = 50 mA Vmax = 28V
CONNECTION SCHEMES
ENERGY MONITORING
SPECIAL FUNCTIONS
-
DAISY-CHAIN CONNECTION
REDUCED WIRING, MINIMUM INFRASTRUCTURE COSTS AND INSTALLATION FLEXIBILITY -
FAULT BYPASS
MAINTAINING THE ETHERNET CHAIN CONNECTION EVEN IN THE EVENT OF A MODULE FAILURE
ORDER CODES
Codes| Description
R203-2-L-E| Three-phase power meter, 2xETH, 24 Vdc, Ethernet/IP
R203-2-H-E| Three-phase power meter, 2xETH, 90-264 Vac, Ethernet/IP
ROGOWSKI COILS
RC150-025-100-3M| Rogowski coil L=25cm Øint. 8cm 100mV/1kA-50Hz, cable L
3m
RC150-035-100-3M| Rogowski coil L=35cm Øint. 11cm 100mV/1kA-50Hz, cable
L 3m
RC150-040-100-3M| Rogowski coil L=40cm Øint. 12cm 100mV/1kA-50Hz, cable
L 3m
RC150-060-100-3M| Rogowski coil L=60cm Øint. 19cm 100mV/1kA-50Hz, cable
L 3m
RC150-090-100-3M| Rogowski coil L=90cm Øint. 28cm 100mV/1kA-50Hz, cable
L 3m
RC150-180-100-3M| Rogowski coil L=180cm Øint. 57cm 100mV/1kA-50Hz, cable
L 3m
RC190-030-333-3M| Rogowski coil L=30cm, Øint. 9cm, 333mV/1kA-50Hz, cable
L 3m
RC190-035-333-3M| Rogowski coil L=35cm, Øint. 11cm, 333mV/1kA-50Hz,
cable L 3m
RC190-060-333-3M| Rogowski coil L=60cm, Øint. 19cm, 333mV/1kA-50Hz,
cable L 3m
RC190-090-333-3M| Rogowski coil L=90cm, Øint. 28cm, 333mV/1kA-50Hz,
cable L 3m
RC190-160-333-3M| Rogowski coil L=160cm, Øint. 50cm, 333mV/1kA-50Hz,
cable L 3m
Via Austria, 26 • 35127 Padova – (I) – Tel. +39 049 87.05.359
Fax +39 049 87.06.287 • www.seneca.it •
info@seneca.it
The material in this document is for information only and is subject to change
without notice. While reasonable efforts have been made in the preparation of
this document to assure its accuracy, SENECA assumes no liability resulting
from errors or omissions, or from the use of the information contained herein.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>