Comfort-aire MG1E-F1ABM Nortek Style Manufactured Housing Furnaces User Guide
- May 15, 2024
- Comfort-Aire
Table of Contents
Comfort-aire MG1E-F1ABM Nortek Style Manufactured Housing Furnaces
MODELS:
E7-Series Electric Furnaces:
- E7ED Downflow Only w/ 31” Coil Cabinet
- E7EM Upflow/Downflow NO CABINET
MG1E-Series 80% AFUE Gas Furnaces:
- MG1E-**F1ABM Downflow w/ 20” Coil Cabinet
- MG1E-**F1AAM Downflow NO CABINET
MG1E-Series 80% AFUE Gas Furnaces:
- MG1E-**F1ABM Downflow w/ 20” Coil Cabinet
- MG1E-**F1AAM Downflow NO CABINET
FLAT ROOF JACKS: Use alone or in combination with wedges below for pitched roofs
- 903658 – Flat Roof Jack 15” to 23”
- 903659 – Flat Roof Jack 21” to 35”
- 903660– Flat Roof Jack 27” to 47”
PITCHED ROOF JACKS: Use alone or in combination with wedges below for higher pitch roofs
- 903664 – 2/12 Pitch Roof Jack 35” to 63”
- 920638 – 2/12 Pitch Roof Jack 51” to 95”
ROOF WEDGES: Use in combination with Flat or Pitched Roof Jacks
- 903893 – 2.5/12 Roof Wedge
- 903894 – 3/12 Roof Wedge
- 903895 – 4/12 Roof Wedge
TO SELECT ROOFJACK: A + B (+X IF PITCHED ROOF)
MG1E-Series 80% AFUE Gas Furnaces NAT GAS Orifice Selection
NATURAL GAS ORIFICES: Use the following steps to determine appropriate orifice for installation altitude.
- Consult Local Utility for “LOCAL HEATING VALUE” at installation site. Use “Local Heating Values” chart to determine if this value is considered “LOW” or “HIGH” based on installation altitude.
- Use “Natural Gas – High Heating Value” or “Natural Gas – Low Heating Value” chart to determine appropriate orifice based on furnace model.
ORIFICE PART NUMBERS:
- 661017R – #17 661018R – #18 661019R – #19** 661020R – #20 661021R – #21
- 661022 – #22 662023R – #23 661024R – #24 661025R – #25 661026R – #26
- 661027 – #27 661028 – #28 661029R – #29 661030R – #30 661031 – #31
- 661032R – #32** 661035 – #35 661036R – #36 661037R – #37 661038 – #38
- 661039R – #39** 661040 – #40 661041R – #41 661042R – #42 661043R – #43
- 661044R – #44 661045R – #45 661046R – #46 661047R – #47 661048R – #48
- 661049R -#49 661050R – #50 661051R – #51 661052R – #52 661055R – #55
- 661056R – #56 661057R – #57 661058R – #58 661059 – #59 661060 – #60
- 661061R – #61
- NOTE : #19, #32, and #39 Orifices have been discontinued. Use the next size smaller orifice**
MG1E-Series 80% AFUE Gas Furnaces PROPANE Orifice Selection
PROPANE ORIFICES: Use the chart below to determine appropriate orifice based on model and installation altitude.
ORIFICE PART NUMBERS:
- 661017R – #17 661018R – #18 661019R – #19** 661020R – #20 661021R – #21
- 661022 – #22 662023R – #23 661024R – #24 661025R – #25 661026R – #26
- 661027 – #27 661028 – #28 661029R – #29 661030R – #30 661031 – #31
- 661032R – #32** 661035 – #35 661036R – #36 661037R – #37 661038 – #38
- 661039R – #39** 661040 – #40 661041R – #41 661042R – #42 661043R – #43
- 661044R – #44 661045R – #45 661046R – #46 661047R – #47 661048R – #48
- 661049R -#49 661050R – #50 661051R – #51 661052R – #52 661055R – #55
- 661056R – #56 661057R – #57 661058R – #58 661059 – #59 661060 – #60
- 661061R – #61
- NOTE : #19, #32, and #39 Orifices have been discontinued. Use the next size smaller orifice**
MG2R-Series 95% AFUE Gas Furnaces:
- MG2R-**F1ABM Downflow w/ 20” Coil Cabinet
- MG2R-**F1ACM Downflow w/ 25” Coil Cabinet
- MG2R-**F1AAM Downflow NO CABINET
MG2R-Series 95% AFUE Gas Furnaces:
- MG2R-**F1ABM Downflow w/ 20” Coil Cabinet
- MG2R-**F1ACM Downflow w/ 25” Coil Cabinet
- MG2R-**F1AAM Downflow NO CABINET
PIPING SIZE TABLE: Combined Intake and Exhaust Max. Length.
Consult IOM for complete venting information.
- Subtract 2.5ft. for each additional 2” Long Radius Elbow, subtract 5ft. for each additional 2” Short Radius Elbow, subtract 3.5ft. for each additional 3” Long Radius Elbow, and 7ft. for each additional 3” Short Radius Elbow.
- Two (2) 45 degree elbows are equivalent to one (1) 90 degree elbow.
- This table applies for elevations from sea level to 2,000ft. elevation. For higher elevations, decrease pipe lengths by 8% per 1000ft. of altitude.
CONCENTRIC PVC KITS: Vertical or Horizontal Intake and Exhaust Termination Kit
- 904952 – 2” Concentric for MG2R
- 904953 – 3” Concentric for MG2R
TRANSITION VENT KIT : Use with Existing Roof Jack Opening
904106 – 2” Transition Vent Kit for MG2R
MG2R-Series 95% AFUE Gas Furnaces NAT GAS Orifice Selection
NATURAL GAS ORIFICES: Use the following steps to determine appropriate orifice for installation altitude.
- Consult Local Utility for “LOCAL HEATING VALUE” at installation site. Use “Local Heating Values” chart to determine if this value is considered “LOW” or “HIGH” based on installation altitude.
- Use “Natural Gas – High Heating Value” or “Natural Gas – Low Heating Value” chart to determine appropriate orifice based on furnace model.
ORIFICE PART NUMBERS:
- 661017R – #17 661018R – #18 661019R – #19** 661020R – #20 661021R – #21
- 661022 – #22 662023R – #23 661024R – #24 661025R – #25 661026R – #26
- 661027 – #27 661028 – #28 661029R – #29 661030R – #30 661031 – #31
- 661032R – #32** 661035 – #35 661036R – #36 661037R – #37 661038 – #38
- 661039R – #39** 661040 – #40 661041R – #41 661042R – #42 661043R – #43
- 661044R – #44 661045R – #45 661046R – #46 661047R – #47 661048R – #48
- 661049R -#49 661050R – #50 661051R – #51 661052R – #52 661055R – #55
- 661056R – #56 661057R – #57 661058R – #58 661059 – #59 661060 – #60
- 661061R – #61
- NOTE : #19, #32, and #39 Orifices have been discontinued. Use the next size smaller orifice**
MG2R-Series 95% AFUE Gas Furnaces PROPANE Orifice Selection
PROPANE ORIFICES: Use the chart below to determine appropriate orifice based on model and installation altitude.
ORIFICE PART NUMBERS:
- 661017R – #17 661018R – #18 661019R – #19** 661020R – #20 661021R – #21
- 661022 – #22 662023R – #23 661024R – #24 661025R – #25 661026R – #26
- 661027 – #27 661028 – #28 661029R – #29 661030R – #30 661031 – #31
- 661032R – #32** 661035 – #35 661036R – #36 661037R – #37 661038 – #38
- 661039R – #39** 661040 – #40 661041R – #41 661042R – #42 661043R – #43
- 661044R – #44 661045R – #45 661046R – #46 661047R – #47 661048R – #48
- 661049R -#49 661050R – #50 661051R – #51 661052R – #52 661055R – #55
- 661056R – #56 661057R – #57 661058R – #58 661059 – #59 661060 – #60
- 661061R – #61
- NOTE : #19, #32, and #39 Orifices have been discontinued. Use the next size smaller orifice**
M5SB-Series 83% AFUE Oil Furnaces:
- M5SB-**A-BW Downflow w/ 20” Coil Cabinet
- M5SB-**A-AW Downflow NO CABINET
M5SB-Series 83% AFUE Oil Furnaces:
- M5SB-**A-BW Downflow w/ 20” Coil Cabinet
- M5SB-**A-AW Downflow NO CABINET
FLAT ROOF JACKS: Use alone or in combination with wedges below for pitched roofs
- 903658 – Flat Roof Jack 15” to 23”
- 903659 – Flat Roof Jack 21” to 35”
- 903660 – Flat Roof Jack 27” to 47”
PITCHED ROOF JACKS: Use alone or in combination with wedges below for higher pitch roofs
- 903664 – 2/12 Pitch Roof Jack 35” to 63”
- 920638 – 2/12 Pitch Roof Jack 51” to 95”
ROOF WEDGES: Use in combination with Flat or Pitched Roof Jacks
- 903893 – 2.5/12 Roof Wedge
- 903894 – 3/12 Roof Wedge
- 903895 – 4/12 Roof Wedge
TO SELECT ROOFJACK: A + B (+X IF PITCHED ROOF)
DUCT CONNECTOR INSTALLATION DETAILS
- E7-Series, MG1E-Series, MG2R-Series, and M5SB-Series
Step 1: Select duct connector based on distance/depth from finished floor to supply duct. Duct connector is lowered into hole through insulation ring. Corresponding hole is cut in supply duct to match duct connector finger/screw tabs
Step 2: Mounting bracket with tabs is slid underneath and Ncentered side- to-side. Duct connector is then attached and sealed to supply duct using industry-approved methods – see furnace installation manual for more details.
Step 3: Duct connector is then attached to the floor using appropriate screws, flat-head nails, or staples.
Step 4: Furnace is slid back to against mounting bracket and secured to floor using methods detailed in install manual.
SPECIFICATIONS
- Rifled copper tubing, enhanced aluminum fins
- Immersion-tested at 500 psi, then nitrogen-pressurized and sealed
- Left-hand refrigerant and plumbing connections
- Externally mounted flowrater body with Schrader valve
- Heavy duty plastic drain pans on all models
- AHRI certifiable with certain brands of A/C and heat pump systems
- UL listed for use with both R-22 and R-410a when proper metering device is used
Line-Set Connection Size
- 1-1/2 – 3 Ton 3/8″ x 3/4″
- 3-1/2 – 5 Ton 3/8″ x 7/8″
DIMENSIONS
Coil Model
| ****
Nominal Tonage
| Dimensions| ****
Weight
| Pallet Qty| R- 22
Piston
---|---|---|---|---|---
Pan Widths (W)”| Pan Depth (D)”| Coil Height (H)”
CMH18/36PM1M| 1.5 – 3| 18″| 19-1/2″| 17″| 32| 8| 0.067
CMH24/30PM1M| 2 – 2.5| 18″| 19-1/2″| 19″| 35| 8| 0.059
CMH24/36PM1M| 2 – 3| 18″| 19-1/2″| 17″| 42| 8| 0.067
CMH36PM2M| 2.5 – 3| 18″| 19-1/2″| 19″| 45| 8| 0.067
CMH42/48PM1M| 3.5 – 4| 18″| 19-1/2″| 19″| 35| 8| 0.076
CMH42/48PM2M| 3.5 – 4| 18″| 19-1/2″| 19″| 45| 8| 0.076
CMH48PM2M| 3.5 – 4| 18″| 19-1/2″| 21″| 48| 4| 0.093
CMH48/60PM1M| 4 – 5| 18″| 19-1/2″| 25″| 46| 4| 0.093
CMH48/60PM2M| 4 – 5| 18″| 19-1/2″| *23″| 49| 4| 0.093
(In reference to coil model number) NOTE: 21″ or taller coils can only be used with the following equipment combinations – Nortek Style:
E7-Series Electric Furnaces (All Models) MG1E/MG2R/M5SB with 922594 26″ Coil Box (NOT FOR STANDARD 20″ COIL BOX)
JCI Style:
EBE-Series Electric Furnaces with 3500-8602 Cabinet Extension
SERVICE COIL DIMENSIONS
__
Coil Model
| __
Nominal Tonage
| Dimensions| __
Weight
| Pallet Qty| R- 22
Piston
---|---|---|---|---|---
Pan Widths (W)”| Pan Depth (D)”| Coil Height (H)”
CMH18/24PM3M| 1.5 – 2| 18″| 19.5″| 11″| 22| 8| 0.053
CMH36PM3M| 3| 18″| 19.5″| 15″| 28| 8| 0.073
CMH42/60PM3M| 3.5 – 5| 18″| 19.5″| 19″| 45| 8| *0.093
Coils are shipped with R-410A pistons already installed. *Same Piston is used for R-22 and R-410A. These are Replacement Service Coils “Only” and are not RATED. For Manufactured Housing Use Only.
PISTONS
Description| Piston Size| Part Number| Tonnage
Outdoor Unit
---|---|---|---
R-22 Pistons
| 41| 176799941| 12
53| 176799953| 18
59| 176799959| 24
67| 176799967| 30
73| 176799973| 36
80| 176799980| 42
84| 176799984| 48
93| 176799993| 60
R-410A Pistons
| 41| 176799941| 12
49| 176799949| 18
53| 176799953| 24
59| 176799959| 30
67| 176799967| 36
73| 176799973| 42
76| 176799976| 48
93| 176799993| 60
“This product complies with all California product labeling laws including, but not limited to, the Safe Drinking Water and Toxic Enforcement Act of 1986, more commonly known as Proposition 65.”
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>