SENECA R203-E Network Analyzers Instruction Manual

June 1, 2024
SENECA

SENECA-logo

SENECA R203-E Network Analyzers

Product Information

Specifications

  • Weight: 170 g
  • Enclosure: UL94-V0 self-extinguishing PC/ABS material, black

Module Layout

  • Width: 106.6 mm
  • Height: 32.2 mm
  • Depth: 90.0 mm

Signals via LED on the Front Panel

The LED signals on the front panel indicate various statuses as listed below:

LED Meaning Status
DO1 Output 01 activated/deactivated On/Off or Flashing
DO2 Output 02 activated/deactivated On/Off or Flashing

Technical Specifications

  • Certifications: ETH1, ETH2
  • Temperature: Environmental
  • Humidity: Conditions

Product Usage Instructions

Installation

  1. Mount the module on a DIN rail 35mm IEC EN60715 or on a wall/panel using screws.
  2. Ensure correct wiring as per the electrical connection diagrams.

Operation

  1. Power on the module.
  2. Monitor the LED signals on the front panel for status indications.

Frequently Asked Questions (FAQ)

Q: What should I do if I encounter a wiring error LED signal?

A: If you see the Wiring Error LED signal, check the wiring connections to ensure they are correct and secure. If the issue persists, contact technical support for assistance.

PRELIMINARY WARNINGS

  • The word WARNING preceded by the symbol indicates conditions or actions that put the user’s safety at risk.
  • The word ATTENTION preceded by the symbol indicates conditions or actions that might damage the instrument or the connected equipment.
  • The warranty shall become null and void in the event of improper use or tampering with the module or devices supplied by the manufacturer as necessary for its correct operation, and if the instructions contained in this manual are not followed.

| WARNING : The full content of this manual must be read before any operation. The module must only be used by qualified electricians. Specific documentation is available using the QR-CODE shown on
---|---
| The module must be repaired and damaged parts replaced by the Manufacturer. The product is sensitive to electrostatic discharges. Take appropriate measures during any operation.
| Electrical and electronic waste disposal (applicable in the European Union and other countries with recycling).

The symbol on the product or its packaging shows the product must be surrendered to a collection center authorized to recycle electrical and electronic waste.

  • This document is the property of SENECA srl. Copies and reproduction are prohibited unless authorized.
  • The content of this document corresponds to the described products and technologies.
  • Stated data may be modified or supplemented for technical and/or sales purposes.

MODULE LAYOUT

SENECA-R203-E-Network-Analyzers-fig-5

SIGNALS VIA LED ON FRONT PANEL

LED STATUS LED meaning
DO1 On Output 01 activated
Off Output 01 deactivated
DO2 On Output 02 activated
Off Output 02 deactivated
DI1 On Input 01 activated
Off Input 01 deactivated
DI2 On Input 02 activated
Off Input 02 deactivated
DATA LOGGER ON The Data Logger function enabled
Flashing LOG sending error
Off Data Logger function disabled
STS (Only R-203-2) On Set IP address (powered module)
Flashing Waiting for the IP address from the DHCP (powered module)

STS

(Only R-203-2-P)

| Off| No IP address set
On| IP address set
Flashing| Active Profinet communication
STS (Only R-203-2-E)| On| Set IP address (powered module)
Flashing| Ethernet/IP communication active
WIRING ERROR| Flashing| Wiring error
Off| Correct wiring
RX| On| RS485 connection anomaly
Flashing| Reception of data packet completed on RS485
TX| Flashing| Transmission of data packet completed on RS485
ETH TRF (Yellow)| Flashing| Packet transit on Ethernet port
ETH LNK (Green)| Flashing| Ethernet port connected

TECHNICAL SPECIFICATIONS

CERTIFICATIONS| SENECA-R203-E-Network-Analyzers-
fig-6
---|---
INSULATION| | |
ENVIRONMENTAL CONDITIONS| Temperature:                     -25°C ÷ +65°C

Humidity:                          30% ÷ 90% non condensing. Storage temperature:          -30°C÷ + 85°C

Degree of protection:          IP20

ASSEMBLY| DIN rail 35mm IEC EN60715, wall or panel with screws.
CONNECTIONS| Screw terminals 5 mm, 7.5 mm, and 3.5 mm pitch (RS485), cable with section <2.5 mm2
POWER SUPPLY| Voltage: 90 ÷ 264Vac @ 50 ÷ 60Hz, max absorption: 2.5W / 4VA (only R203-2-H) Voltage: 10 ÷ 30Vdc, max absorption: 2.5W / 4VA (only R203-2-L)
COMMUNICATION PORTS| RS485: Baud rate: 1200 ÷ 115200 baud (for further information see the user manual). Ethernet ports 2 (model R203-2); 1 (model R203-1)
VOLTAGE INPUT| Voltage| Up to 600 Vac, frequency 45 ÷ 65Hz

Minimum voltage 5 V (F.S. 150 Vac); 20 V (F.S. 600 Vac)

ANALOGUE INPUT TA / TA (mV)| Current input| Current input for TA: 1 ÷ 5A full scale.

Voltage input (mV) for TA with voltage or Rogowski output: up to 250 mV.

Base price. (*)| Network frequency: 50 ÷ 60 Hz. Voltmeter: 0.2%

Ammeter: 0.2%, wattmeter: 0.5%

(*) See the user manual for the error limits.
ROGOWSKI ANALOGUE INPUT

(100 mV/kA)

| Class/base price. (*)| Network frequency: 50 ÷ 60 Hz. Voltmeter: 0.5%

Ammeter: 0.5%, wattmeter: 1%

Rogowski supplied by Seneca

| •  100 mV correspond to 1000 A @ 50 Hz (sinusoidal)

•  120 mV correspond to 1000 A @ 60 Hz (sinusoidal) Maximum measurable current: 2500A @50Hz, 2000A @60Hz

Precision after calibration: ± 1 % (see chapter “Rogowski sensor”)

Linearity: ± 0.2 %

(*) Accuracy is guaranteed in the ranges: CosΦ > 0.5; Vrms: 40 ÷ 600 Vac; Irms: 5 – 100% Rogowski current (error due to external Rogowski sensors excluded). See the user manual for the error limits.
ANALOGUE OUTPUT| Voltage:                      0÷ 10Vdc, minimum load resistance: 2kΩ

Current:                      0 ÷ 20 mA, max. load resistance: 500Ω Transmission error:          0.1% of maximum field

Response time:           1 s (10% ÷ 90%) Temperature drift: 100 ppm/K

DIGITAL INPUT| For the technical specifications, see the electrical connection diagrams on page 5
DIGITAL OUTPUT| For the technical specifications, see the electrical connection diagrams on page 5
COUNTERS| Number of counters: 2 at 32-bit, maximum speed: 5 KHz
INSTALLATION CATEGORY| Category ⅡI (up to 600 V) in a direct connection (only R203-2-H)

Category ⅡI (up to 300 V) in a direct connection (only R203-2-L)

CAUTION

This is a Class A product. In a residential environment, this equipment may cause radio interference. In this case, the user may have to take adequate countermeasures.

ROGOWSKI SENSOR

The Rogowski sensor is a ring-shaped device designed for measuring AC, impulsive, or complex waveforms.

For its correct use:

  • wrap the ring on the conductor so that the arrow symbol on the ring points in the same direction as the current in the conductor
  • make sure the connections are made correctly
  • for a more precise measurement, the conductor wire must be placed in a central position to the ring
  • for a correct measurement, calibrate the Rogowski sensor by writing the calibration coefficient in the corresponding Modbus register (see the user manual).
  • Example: if the sensor is supplied with a characteristic of 90 mV / 1000 A, on the calibration register corresponding to the phase in which the Rogowski sensor is applied, the value to be set is: 1000/ (90 · 10) = 1.11
  • NOTE   ON ACCURACY: The product has a nominal accuracy of 0.5%. The total accuracy is the sum between the accuracy of the device and the accuracy of the Rogowski sensor connected to it.SENECA-R203-E-Network-Analyzers-fig-10
  1. CONDUCTOR (+)
  2. CONDUCTOR (-)
  3. SCREEN (if any)

DIP – SWITCH SETTINGS

  • The DIP-switch settings are read only at boot time. At each change, perform a restart.
  • For use and settings via DIP-SWITCH, see the user manual available on the website on the web page dedicated to the product.

ELECTRICAL CONNECTIONS

SENECA-R203-E-Network-Analyzers-fig-11

CAUTION

  • The installation of this appliance must only be carried out by qualified personnel.
  • Check that the device plate data (measurement voltage, auxiliary power supply voltage, measurement current, frequency) match the actual data of the network to which the instrument is connected.
  • In the wiring, strictly observe the insertion diagram; inaccuracy in the connections inevitably causes false measurements or damage to the instrument.
  • Once the instrument is connected, complete the installation with the device configuration.
  • The earth connection of the secondary of CTs with current, voltage, or rogowski output is possible on the negative terminal. In the case of rogowski sensors, the screen must always be connected to the negative terminal.
  • Current measurement is only possible using current transformers.
  • It is advisable to insert a slow-blow 1 A fuse as indicated in the diagrams below.SENECA-R203-E-Network-Analyzers-fig-12 SENECA-R203-E-Network-Analyzers-fig-13 SENECA-R203-E-Network-Analyzers-fig-14

FACTORY IP ADDRESS

  • The default module IP address is static: 192. 168. 90. 101
  • In the R-203-X-P version, the module is supplied without an IP address (0.0.0).

WEB SERVER

  • To access the Web Server with the factory IP address above, use the following credentials: Username: admin; Password: admin

CAUTION

  • DO NOT USE DEVICES WITH THE SAME IP ADDRESS IN THE SAME ETHERNET NETWORK.

ETHERNET CONNECTION RULES

For the Ethernet cabling between the devices, the use of the shielded CAT5 or CAT5e cable is required.

DAISY-CHAIN ETHERNET CONNECTION

CAUTIONSENECA-R203-E-Network-Analyzers-fig-15 IT IS NOT ALLOWED TO CREATE LOOPS WITH ETHERNET CABLES Using the daisy-chain connection it is not necessary to use switches to connect the devices. The following examples show the correct connections.SENECA-R203-E-Network-
Analyzers-fig-16

The LAN fault-bypass function allows you to keep the connection between the two Ethernet ports of the device ON, in the event of a power failure. If a device turns off, the chain is not interrupted and the devices downstream of the switched-off one will still be accessible. This function has a limited duration: the connection remains active for a few days, typically 4. The fault-bypass function requires that the sum of the lengths of the two cables connected to the switched-off module is less than 100m.