BEGA 84 935 Compact Floodlight Instruction Manual
- June 1, 2024
- BEGA
Table of Contents
BEGA 84 935 Compact Floodlight
Product Specifications
- Lamp Module connected wattage: 10.2 W
- Luminaire connected wattage: 11.8 W
- Rated temperature: 25 – 55 °C
- Ambient temperature: 25 – 55 °C
- Colour temperature: 3000 K (LED-1148/930) and 4000 K (LED-1148/940)
- Colour rendering index (CRI): > 90
- Module luminous flux: 1500 lm (LED-1148/930) and 1575 lm (LED-1148/940)
- Luminaire luminous flux: 1098 lm (LED-1148/930) and 1153 lm (LED-1148/940)
- Luminaire luminous efficiency: 93.1 lm/W (LED-1148/930) and 97.7 lm/W (LED-1148/940)
Overvoltage Protection:
The luminaire comes with overvoltage protection in accordance with DIN EN
61547. For additional protection against transients, it is recommended to use
separate overvoltage protection components available on the manufacturer’s
website.
Safety Guidelines
Installation and operation of the luminaire should be done following national
safety regulations. Only qualified electricians should carry out installation
and commissioning. The manufacturer will not be liable for damage resulting
from improper use or installation. Any modifications to the luminaire should
be performed by authorized personnel..
Frequently Asked Questions (FAQ)
Q: Can I install the luminaire myself?
A: The installation and commissioning should only be carried out by a
qualified electrician to ensure safety and proper functionality.
Compact floodlight
Instructions for use
Application
Compact floodlight with mounting box for permanent installations on a wall,
under a ceiling or on a pillar.
Product description
- Luminaire made of aluminium alloy, aluminium and stainless steel
- BEGA Unidure® coating technology
- Colour graphite or silver
- Clear safety glass
- Reflector surface made of pure aluminium Rotation range of floodlight 350°
- Swivel range -20°/+90°
- Mounting box with 2 fixing holes
- ø 6 mm · 85 mm spacing
- 2 cable entries for through-wiring of mains supply cable ø 7-10.5 mm, max. 5 G 1.5@ Connecting terminal 2.5@
- with plug connection
- Earth conductor connection
- BEGA Ultimate Driver®
- Complies with flicker requirements in accordance with IEEE 1789,
- DIN IEC/TR 63158, DIN IEC/TR 61547-1 LED power supply unit
- 220-240 V 0/50-60 Hz
- DC 176-264 V
- DALI-controllable
- Number of DALI addresses: 1
- Basic insulation is provided between the mains and control cables
- BEGA Thermal Control®
- Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
- Safety class I
- Protection class IP 65
- Dust-tight and protection against water jets Impact strength IK09
- Protection against mechanical
- impacts < 10 joule
- – Safety mark
- – Conformity mark
- Wind catching area: 0.058 m²
- Weight: 5.0 kg
- This product contains light sources of energy efficiency class(es) D
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Installation
Screw the floodlight G½ threaded connection firmly into the on-site G½ female
thread or BEGA accessory.
G½ threaded connection torque = 40 Nm. Secure the screw connection from
loosening on site (if provided with locking screw S, see fig. A).
Check the earth conductor connection between the G½ threaded connection and
the on-site G½ female thread.
Adjust
floodlight:
Undo hexagon socket screw (wrench size 5 mm) and hexagon nut (wrench size 30
mm) and set the desired beam direction.
Torque :
- Hexagon socket screw = 7 Nm
- Hexagon nut = 35 Nm
- Secure bolted connection Gß against loosening by tightening the hexagon socket screw (wrench size 2 mm) (see sketch B, C).
- The electrical connection must be carried out with matching protection class and safety class, strain-relieved, with suitable connection terminals (not included in the scope of delivery) at the luminaire power supply cable.
- Note correct configuration of the mains supply cable.
- Make mains supply connection at the brown (L), blue (N) and green-yellow lead (1) .
- The connection of the control cables is achieved by means of the both leads marked with DALI.
- In case these leads are not used the luminaire will be operated at full light output.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Lamp
- Module connected wattage 10.2 W
- Luminaire connected wattage 11.8 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 55 °C
84 935 K3
- Module designation LED-1148/930
- Colour temperature 3000 K
- Colour rendering index CRI > 90
- Module luminous flux 1500 lm
- Luminaire luminous flux 1098 lm
- Luminaire luminous efficiency 93,1 lm / W
84 935 K4
- Module designation LED-1148/940
- Colour temperature 4000 K
- Colour rendering index CRI > 90
- Module luminous flux 1575 lm
- Luminaire luminous flux 1153 lm
- Luminaire luminous efficiency 97,7 lm / W
Light technique
- Broad spread light distribution.
- Half beam angle 45°
- For special lighting applications, an optical filter can be used to change the symmetrical light cone into a flat beam light distribution.
Replacing the LED module
- The designation of the LE
- Dmodule is noted on a separate label in the luminaire or on the underside of the specific LED module.
- The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The replacement can be carried out by a qualified person using standard tools.
- Disconnect the system from the power supply. Open the floodlight:
- Remove the trim ring along with the safety glass and reflector by twisting it anti-clockwise. Replace LED module.
- Please follow the installation instructions for the LED module.
- Inspect and, if necessary, replace the luminaire gaskets.
- Defective glass must be replaced.
- Place the trim ring with glass and reflector on the floodlight housing so that the notches in the trim ring and luminaire housing sit on top of each other.
- Twist on the trim ring clockwise as far as the stop.
Accessories
- 71 279 Shield
- 71 289 Optical filter flat beam
- 71 042 Adapter for installation on a pole 70 204 Earth spike
- 70 214 Pole cap for pole ø 48 mm
- 70 248 Pole cap for pole ø 60 mm
- 70 245 Mounting box
- 70 252 General fastener
- 70 280 Tube clamp G½
- 70 283 Screw clamp
- 70 379 Cross beam G½
- 70 889 Tension belt
For the accessories a separate instructions for use can be provided upon request.
Spares
- Trim ring graphite mit Glas 25 000 246
- Trim ring silver mit Glas 25 000 247
- LED power supply unit DEV-0475/300
- LED module 3000 K LED-1148/930
- LED module 4000 K LED-1148/940
- Reflector 75 005 131
- Gasket trim ring 83 002 169
- Gasket housing 83 002 171
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com