Westinghouse WGen9500TFc Generator Tri-Fuel with CO Sensor User Guide

June 1, 2024
Westinghouse

Westinghouse WGen9500TFc Generator Tri-Fuel with CO Sensor

Westinghouse-WGen9500TFc-Generator-Tri-Fuel-with-CO-Sensor-
product

Product Information

Specifications

  • Engine Type: 4-stroke
  • Power Source: Gasoline, Propane, Natural Gas
  • Includes: Funnel, 4-stroke engine oil

FAQ

WARNING: This Quick Start Guide is not a substitute for reading the operator’s manual. To reduce the risk of injury or death, user must read and understand operator’s manual before using this product.

TOOLS YOU WILL NEED

Westinghouse-WGen9500TFc-Generator-Tri-Fuel-with-CO-Sensor-
fig-1

BEFORE STARTING

  1. Install the feet and wheelsWestinghouse-WGen9500TFc-Generator-Tri-Fuel-with-CO-Sensor-fig-2
    • Secure feet to the bottom of the frame using bolts
    • Insert axles through wheels, washers, and frame; secure with hitchpins
  2. Connect the battery cablesWestinghouse-WGen9500TFc-Generator-Tri-Fuel-with-CO-Sensor-fig-3
  3. Add engine oilWestinghouse-WGen9500TFc-Generator-Tri-Fuel-with-CO-Sensor-fig-4
    • Slowly add 4-cycle engine oil until full. Do not overfill.
  4. Add gasoline or connect a fuel sourceWestinghouse-WGen9500TFc-Generator-Tri-Fuel-with-CO-Sensor-fig-5
    • Gasoline – Unscrew gas cap and slowly add gasoline. Do not overfill.
    • Propane – Connect the LPG/propane hose to a propane cylinder and the generator.
    • Natural Gas – Connect the natural gas hose to a natural gas supply line and the generator.

SELECTING THE FUEL SOURCE

Westinghouse-WGen9500TFc-Generator-Tri-Fuel-with-CO-Sensor-
fig-6

  1. For gasoline, rotate the fuel selector switch to GASOLINE and open the fuel valve.
  2. For propane, rotate the fuel selector switch to PROPANE and open the propane cylinder valve.
  3. For propane, rotate the fuel selector switch to NATURAL GAS and open the propane cylinder valve.

STARTING PROCEDURE

  1. Make sure all loads are disconnected from the generator and select a fuel source.Westinghouse-WGen9500TFc-Generator-Tri-Fuel-with-CO-Sensor-fig-10
  2. Push the battery switch to the ON position
  3. For manual start, move the choke to the off/ cold start position and pull the recoil handle repeatedly until the generator starts. If the engine is warm, move the choke towards the on/warm start position (about 2/3 of the way)
  4. For remote start, push and hold the start button on the key fob for two seconds
  5. For push button start, push and hold the engine START/STOP button for two seconds
  6. Ensure breakers are ON and connect loads to the control panel receptacles

SHUTDOWN PROCEDURE

Westinghouse-WGen9500TFc-Generator-Tri-Fuel-with-CO-Sensor-
fig-12

  1. Make sure all loads are disconnected from the generator
  2. Turn the fuel selector switch to FUEL OFF and stop the flow of fuel by closing the fuel valve, cylinder valve, or the valve on the natural gas hose.
  3. Press and hold the engine START/STOP button or the stop button on the key fob for one second to stop the generator
  4. Push the battery switch to the OFF position

GENERATOR MECHANICAL SPECIFICATIONS


Model Number

| Running Watts| Peak Watts| Fuel Tank Size (L/G)| Rated Speed (RPM)| Ignition Type| ****

Engine Disp (cc)

| ****

Oil Capacity (L)

| Oil Type| THD
---|---|---|---|---|---|---|---|---|---
WGen9500TFc| 9500

Gasoline

| 12500

Gasoline

| 25/6.6| 3600| TCI| 457| 1.1| 10W30| £ 23%

MAINTENANCE SCHEDULE

Following the maintenance schedule is important to keep the generator in good operating condition. The following is a summary of maintenance items by periodic maintenance intervals. Refer to the Maintenance section in the Owners Manual to find out how to properly perform maintenance.

TABLE 1: MAINTENANCE SCHEDULE

Maintenance Item| ****

Before Every Use

| After First 25 Hours or First Month of Use| After 50 Hours of Use or Every 6 Months| After 100 Hour of Use or Every 6 Months| After 300 Hours of Use or Every Year
---|---|---|---|---|---
Engine Oil| Check Level| Change1| Change| –| –
Air Filter| –| –| Clean2| –| Replace
Spark Plug| –| –| –| Check/Clean| Replace
Spark Arrestor| –| –| –| Check/Clean| –
Fuel Filter| –| –| –| Replace3| –
Valve Clearance| –| –| –| Inspect/Adjust3| –

  • 1 Change oil every month when operating under heavy load or in high temperatures.
  • 2 Clean more often under dirty or dusty conditions.
  • 3 Recommended service by authorized Westinghouse dealer.

ENGINE OIL

  • Only use 4-stroke/cycle engine oil. NEVER USE 2-STROKE/CYCLE OIL. Synthetic oil is an acceptable substitute for conventional oil.

Recommended Engine Oil Type

Westinghouse-WGen9500TFc-Generator-Tri-Fuel-with-CO-Sensor-
fig-14

SPARK PLUG REPLACEMENT

Westinghouse Model Number Torch Bosch NGK
WGen9500TFc F7TC W7DC BP6ES

Danger

Westinghouse-WGen9500TFc-Generator-Tri-Fuel-with-CO-Sensor-
fig-15

Contact

QR code

For customer support, scan the QR code.

Questions?

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Westinghouse User Manuals

Related Manuals