Westinghouse F7TC Standard Powersports Spark Plug User Guide

June 1, 2024
Westinghouse

Westinghouse F7TC Standard Powersports Spark Plug User Guide
Westinghouse F7TC Standard Powersports Spark Plug

WARNING This Quick Start Guide is not a substitute for reading the operator’s manual. To reduce the risk of injury or death, user must read and understand operator’s manual before using this product

TOOLS YOU WILL NEED

Fresh clean unleaded gasoline (not included)

Funnel (included)

4-stroke engine oil (included)

BEFORE STARTING

  1. Install the feet and wheels
    a. Secure feet to the bottom of the frame using bolts
    Using Bolts
    b. Insert axles through wheels, washers, and frame; secure with hitchpins
    Insert Axles

  2. Connect the battery cables

  3. Add engine oil
    Slowly add 4-cycle engine oil until full. Do not overfill.
    Add Engine Oil

  4. Add gasoline or connect a fuel source
    a. Gasoline – Unscrew gas cap and slowly add gasoline. Do not overfill.
    Add Gasoline
    b. Propane – Connect the LPG/propane hose to a propane cylinder and the generator.
    Add Gasoline
    c. Natural Gas – Connect the natural gas hose to a natural gas supply line and the generator.
    Add Gasoline

SELECTING THE FUEL SOURCE

  1. For gasoline, rotate the fuel selector switch to GASOLINE and open the fuel valve.
    Selecting Source

  2. For propane, rotate the fuel selector switch to PROPANE and open the propane cylinder valve.
    Selecting Source

  3. For propane, rotate the fuel selector switch to NATURAL GAS and open the propane cylinder valve.
    Selecting Source

STARTING PROCEDURE

  1. Make sure all loads are disconnected from the generator and select a fuel source.

  2. Push the battery switch to the ON position
    Starting Procedure

  3. For manual start, move the choke to the off/ cold start position and pull the recoil handle repeatedly until the generator starts. If the engine is warm, move the choke towards the on/warm start position (about 2/3 of the way).
    On/Warm Start

**Off/Cold Start

Starting Procedure**

  1. For remote start, push and hold the start button on the key fob for two seconds
    Starting Procedure

  2. For push button start, push and hold the engine START/STOP button for two seconds
    Starting Procedure

  3. Ensure breakers are ON and connect loads to the control panel receptacles

SHUTDOWN PROCEDURE

  1. Make sure all loads are disconnected from the generator.

  2. Turn the fuel selector switch to FUEL OFF and stop the flow of fuel by closing the fuel valve, cylinder valve, or the valve on the natural gas hose.
    Shutdown Procedure

  3. Press and hold the engine START/STOP button or the stop button on the key fob for one second to stop the generator.
    Shutdown Procedure

  4. Push the battery switch to the OFF position
    Shutdown Procedure

GENERATOR MECHANICAL SPECIFICATIONS

Model Number| Running Watts| Peak Watts| Fuel Tank Size (L/G)| Rated Speed (RPM)| Ignition Type| Engine Disp (cc)| Oil Capacity (L)| Oil| THD
---|---|---|---|---|---|---|---|---|---
WGen10500TFc| 10500 Gasoline| 13500 Gasoline| Fuel Tank Size (L/G)| 3600| TCI| 500| 1.2| 10W30| ≤ 23%

MAINTENANCE SCHEDULE

Following the maintenance schedule is important to keep the generator in good operating condition. The following is a summary of maintenance items by periodic maintenance intervals. Refer to the Maintenance section in the Owners Manual to find out how to properly perform maintenance.

TABLE 1: MAINTENANCE SCHEDULE

Maintenance Item| Before Every Use| After First 25 Hours or First Month of Use| After 50 Hours of Use or Every 6 Months| After 100 Hour of Use or Every 6 Months| After 300 Hours of Use or Every Year
---|---|---|---|---|---
Engine Oil| Check Level| Change1| Change| –| –
Air Filter| –| –| Clean2| –| Replace
Spark Plug| –| –| –| Check/Clean| Replace
Spark Arrestor| –| –| –| Check/Clean| –
Fuel Filter| –| –| –| Replace3| –
Valve Clearance| –| –| –| Inspect/Adjust3| –

  1. Change oil every month when operating under heavy load or in high temperatures.
  2. Clean more often under dirty or dusty conditions.
  3. Recommended service by authorized Westinghouse dealer.

ENGINE OIL

Only use 4-stroke/cycle engine oil. NEVER USE 2-STROKE/CYCLE OIL

Instructions

SPARK PLUG REPLACEMENT

Model Number Torch Bosch NGK
WGen10500TFc F7TC W7DC BP6ES

DANGER

Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide.
This is a poison you cannot see or smell.


NEVER
use inside a home or garage,
EVEN IF doors and windows are open.

Only use OUTSIDE and far away from windows, doors, and vents.

For customer support, scan the QR code.

125358 03/05/24
WGen10500TFc Rev 03

Questions? Call 855.944.3571 or
visit wpowereq.com/pages/support

¿Tiene preguntas? Llame al 855.944.3571 o visite wpowereq.com/pages/support