Westinghouse F7TC Standard Powersports Spark Plug User Guide
- June 1, 2024
- Westinghouse
Table of Contents
Westinghouse F7TC Standard Powersports Spark Plug User Guide
WARNING This Quick Start Guide is not a substitute for reading the operator’s manual. To reduce the risk of injury or death, user must read and understand operator’s manual before using this product
TOOLS YOU WILL NEED
Fresh clean unleaded gasoline (not included)
Funnel (included)
4-stroke engine oil (included)
BEFORE STARTING
-
Install the feet and wheels
a. Secure feet to the bottom of the frame using bolts
b. Insert axles through wheels, washers, and frame; secure with hitchpins
-
Connect the battery cables
-
Add engine oil
Slowly add 4-cycle engine oil until full. Do not overfill.
-
Add gasoline or connect a fuel source
a. Gasoline – Unscrew gas cap and slowly add gasoline. Do not overfill.
b. Propane – Connect the LPG/propane hose to a propane cylinder and the generator.
c. Natural Gas – Connect the natural gas hose to a natural gas supply line and the generator.
SELECTING THE FUEL SOURCE
-
For gasoline, rotate the fuel selector switch to GASOLINE and open the fuel valve.
-
For propane, rotate the fuel selector switch to PROPANE and open the propane cylinder valve.
-
For propane, rotate the fuel selector switch to NATURAL GAS and open the propane cylinder valve.
STARTING PROCEDURE
-
Make sure all loads are disconnected from the generator and select a fuel source.
-
Push the battery switch to the ON position
-
For manual start, move the choke to the off/ cold start position and pull the recoil handle repeatedly until the generator starts. If the engine is warm, move the choke towards the on/warm start position (about 2/3 of the way).
On/Warm Start
**Off/Cold Start
**
-
For remote start, push and hold the start button on the key fob for two seconds
-
For push button start, push and hold the engine START/STOP button for two seconds
-
Ensure breakers are ON and connect loads to the control panel receptacles
SHUTDOWN PROCEDURE
-
Make sure all loads are disconnected from the generator.
-
Turn the fuel selector switch to FUEL OFF and stop the flow of fuel by closing the fuel valve, cylinder valve, or the valve on the natural gas hose.
-
Press and hold the engine START/STOP button or the stop button on the key fob for one second to stop the generator.
-
Push the battery switch to the OFF position
GENERATOR MECHANICAL SPECIFICATIONS
Model Number| Running Watts| Peak Watts| Fuel Tank Size
(L/G)| Rated Speed (RPM)| Ignition Type| Engine Disp (cc)|
Oil Capacity (L)| Oil| THD
---|---|---|---|---|---|---|---|---|---
WGen10500TFc| 10500 Gasoline| 13500 Gasoline| Fuel Tank Size (L/G)| 3600| TCI|
500| 1.2| 10W30| ≤ 23%
MAINTENANCE SCHEDULE
Following the maintenance schedule is important to keep the generator in good operating condition. The following is a summary of maintenance items by periodic maintenance intervals. Refer to the Maintenance section in the Owners Manual to find out how to properly perform maintenance.
TABLE 1: MAINTENANCE SCHEDULE
Maintenance Item| Before Every Use| After First 25 Hours or First
Month of Use| After 50 Hours of Use or Every 6 Months| After 100
Hour of Use or Every 6 Months| After 300 Hours of Use or Every Year
---|---|---|---|---|---
Engine Oil| Check Level| Change1| Change| –| –
Air Filter| –| –| Clean2| –| Replace
Spark Plug| –| –| –| Check/Clean| Replace
Spark Arrestor| –| –| –| Check/Clean| –
Fuel Filter| –| –| –| Replace3| –
Valve Clearance| –| –| –| Inspect/Adjust3| –
- Change oil every month when operating under heavy load or in high temperatures.
- Clean more often under dirty or dusty conditions.
- Recommended service by authorized Westinghouse dealer.
ENGINE OIL
Only use 4-stroke/cycle engine oil. NEVER USE 2-STROKE/CYCLE OIL
SPARK PLUG REPLACEMENT
Model Number | Torch | Bosch | NGK |
---|---|---|---|
WGen10500TFc | F7TC | W7DC | BP6ES |
DANGER
Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust
contains carbon monoxide.
This is a poison you cannot see or smell.
NEVER use inside a home or garage,
EVEN IF doors and windows are open.
Only use OUTSIDE and far away from windows, doors, and vents.
For customer support, scan the QR code.
125358 03/05/24
WGen10500TFc Rev 03
Questions? Call 855.944.3571 or
visit wpowereq.com/pages/support
¿Tiene preguntas? Llame al 855.944.3571 o visite
wpowereq.com/pages/support
Des questions? Téléphoner au 855 944-3571 ou visitez
wpowereq.com/pages/support
Read User Manual Online (PDF format)