BEGA 24 899 Recessed Ceiling Luminaire Instruction Manual

June 1, 2024
BEGA

BEGA 24 899 Recessed Ceiling Luminaire

BEGA-24-899-Recessed-Ceiling-Luminaire-product

Product Information

Specifications

  • Product Name: Recessed Ceiling Light Fixture
  • Model Number: 24,899
  • Application: Indoor and outdoor installation in concrete or suspended ceilings

FAQ

  • Q: Can this luminaire be installed outdoors?
    • A: Yes, this luminaire is suitable for installation both indoors and outdoors.
  • Q: What is the recommended method for protecting electronic components?
    • A: To protect electronic components, it is recommended to use bounce-free switching contacts like an electronic relay, such as BEGA 71 320.

Dimensions

BEGA-24-899-Recessed-Ceiling-Luminaire-fig-1

Application

  • Recessed ceiling luminaire with attached connecting cable for installation into concrete ceilings or suspended ceilings both indoors and out.
  • With symmetrical wide beam light distribution.

Product Description

  • Luminaire made of aluminium alloy, aluminium and stainless steel
  • BEGA Unidure® coating technology
  • Colour graphite or white
  • Clear safety glass
  • Reflector surface made of pure aluminium
  • Luminaire housing with 2 fixing claws and guide screws
  • Recessed opening ø 160 mm
  • Required installation depth 120 mm
  • Connecting cable H05RN-F 3 G 1@ with free line ends
  • Cable length 0,5 m
  • Complies with flicker requirements in accordance with IEEE 1789,
  • DIN IEC/TR 63158, DIN IEC/TR 61547-1
  • LED power supply unit: 220-240 V 0/50-60 Hz
  • DC 170-276 V
  • BEGA Thermal Switch®
  • Temporary thermal shutdown to protect temperature-sensitive components
  • Safety class I
  • Protection class IP 65
  • Dust-tight and protection against water jets
  • CE – Conformity mark
  • This product contains light sources of energy efficiency class(es) B

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.
  • The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71 320.

Specifications

Lamp

  • Module connected wattage 13.7 W
  • Luminaire connected wattage 15.5 W
  • Rated temperature ta = 25 °C
  • Service life criteria 50 000 h / L70

24 899 K3

  • Module designation LED-1628/830
  • Colour temperature 3000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 2820 lm
  • **Luminaire luminous flux *** 1980 lm
  • **Luminaire luminous efficiency *** 127,7 lm / W

24 899 K4

  • Module designation LED-1628/840

  • Colour temperature 4000 K

  • Colour rendering index CRI > 80

  • Module luminous flux 2890 lm

  • **Luminaire luminous flux *** 2030 lm

  • **Luminaire luminous efficiency *** 131 lm / W

  • preliminary data

Lighting technology

  • Half beam angle 40°

Installation

  • Luminaire housing must not be installed in heat-insulating material.
  • The recessed opening is covered by the frame of the luminaire housing.
  • Fixing of the luminaire in the structure is achieved by using two adjustable wedge-shaped claws.
  • A recessed opening of ø 160 mm with a minimum depth of 120 mm is required.
  • The lateral distance between the luminaire housing and parts of the building must be at least 50 mm.
  • The claws grip behind the ceiling cladding. The minimum thickness of the ceiling cladding is 1 mm.
  • Ensure that the suspended ceiling and wall surfaces have sufficient load-bearing capability.
  • If the thickness is less, and if installation is to be carried out in plasterboard ceilings, the back of the ceiling cladding must be reinforced in the region of the claws.
  • The electrical connection of the free cable end must be carried out with matching protection class and safety class, relieved of strain, with suitable connection terminals in a suitable connection box (not included in the scope of delivery).
  • Note correct configuration of the mains supply cable. Make mains supply connection at the black (L), blue (N) and green-yellow lead ( ).
  • Insert luminaire housing into the recessed opening. Hand-tighten screws of the claw fastener (torx drive T15) evenly. Do not use an electric screwdriver!
  • When tightening the screws, the fixing claws must swivel onto the inside of the suspended ceiling. The luminaire is fixed.
  • When undoing the guide screws, the fixing claws swivel back and the luminaire can be removed.

Maintenance And Replacing the LED module

Cleaning / Maintenance

  • Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
  • Do not use high pressure cleaners.

Please note:

  • Do not remove the desiccant bag from the luminaire housing.
  • It is needed to remove residual moisture.

Replacing the LED module

  • The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire.
  • Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • Defective glass must be replaced.
  • Close the luminaire.

Spares

  • Spare glass 14 000 383
  • LED power supply unit DEV-0341/350
  • LED module 3000 K LED-1628/830
  • LED module 4000 K LED-1628/840
  • Reflector with diffuser disk 76 002 149
  • Reflector 76 002 154
  • Gasket glass 83 002 316

Contact

BEGA Gantenbrink-Leuchten KG

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals