virax 2950 Descaling Pump
Product Information
- Product Name: Descaling Pump
- Languages: EN, IT, ES, PT, NL, PL, DE, EL, RU, TR
- Compliance: EN 60335-2-41, EN 55014-1:2006+A1:2009+A2:2011, EN 55014-2:1997+A1:2001+A2:2008+IS1 :2007, EN 61000-3-2:2006+A1:2009+A2:2009, EN 61000-3-3:2008
- Manufacturer: Virax
- Quality & EHS Manager: Olivier Rosenzweig
- Technical File Location: VIRAX 39 Quai de Marne / CS 40197, 51206 Epernay Cedex FRANCE
- Product Warranty: 2 years
Product Usage Instructions
Safety Instructions:
- Read and keep the instructions provided.
- Observe basic safety measures to reduce the risk of electric discharge or fire when using electric tools.
General Safety Instructions:
- Always use the correct tool for the job and do not use accessories or attachments that are insufficient for heavy-duty tasks.
- Do not use tools for purposes other than their intended use.
- Store the tool in a safe and dry place when not in use, or out of reach of children.
- Keep the tool clean for better and safer performance, following the maintenance instructions and recommendations for accessory changing.
- Ensure the handles are dry and free of oil or grease.
- Before using the tool, carefully check all parts for proper operation, including moving parts, mounting, and any damage or defects.
- Any damaged or defective parts should be repaired or replaced by a qualified technician.
Product Maintenance and Storage:
- To ensure the proper functioning of the pump, only use VIRAX chemical products (2950XX product range).
EU Declaration of Conformity
- We declare under our own responsibility that the product described below conforms to the applicable Union harmonization legislation.
Quality & EHS Manager Epernay, 15 Oct. 2021
Do not dispose of power tools or batteries with household garbage! Specialized places exist to collect and recycle batteries and power tools, according to the European directives 2013/56/EU and 2012/19/EU.
Spare parts
Safety instructions
Read and keep these instructions. Observe the following basic safety measures to reduce the risk of electric discharge or fire when using electric tools.
General safety instructions
Choice of tool
- Always use the correct tool for the job. Do not use accessories or attachments of insufficient capacity to perform heavy-duty tasks. Do not use tools for any other purpose than that for which they have been designed.
Maintenance and storage
- Store your tools in a safe place. When not in use, tools should be stored in a dry, closed place, out of reach of children.
- Carefully maintain your tools. Keep them clean for better and safer performance. Follow the maintenance instructions as well as the recommendations regarding the changing of accessories. Keep the handles dry and free of oil or grease.
- Check the tool for damage. Before using the tool, always carefully check that its various parts are operating properly. Check for incorrect operation of moving parts, seizing of moving parts and breakage of parts. Check for proper mounting of all parts and any other conditions that may prevent the perfect operation of the tool. Any guard, switch or other part that is damaged or defective should be properly repaired or replaced by a qualified technician.
- Warning! Use the tool and its accessories in accordance with these safety instructions. Also remain within the limits of the tool, taking into account the working conditions and the task to be performed. Using tools for other than the intended tasks can be dangerous.
- This tool is in accordance with all the relevant safety rules. All repairs must be performed by qualified persons using the original manufacturer’s spare parts. Failure to do so may be dangerous for the user and cancel the warranty.
User safety instructions
- Keep children away from the tools. Do not allow other people to touch the tool. Keep them away from your work area.
- Wear appropriate clothing. Do not wear loose clothing or jewelry, as they can become caught in moving parts.
- Rubber gloves and non-slip footwear are recommended when working out of doors. Long hair should be worn in a hair net.
- Do not overreach. Avoid adopting a tiring position. Keep proper footing and balance at all times.
- Be constantly alert. Pay attention to the task, use common sense, and do not operate the tool when tired.
Safety instructions regarding the working area
- Keep the work area tidy. A cluttered work area increases the risk of injury.
- Consider the work area environment. Do not expose electric tools to the rain. Do not use electric tools in a damp or wet environment.
- Keep the work area well-lit. Do not use electric tools in the vicinity of flammable liquids or gasses.
Specific safety guidelines
- To guarantee proper operation of the pump, use only VIRAX chemicals (product range 2950XX)
- Noncompliance with safety instructions and warnings in this manual and on the labels can cause a danger to persons and the environment.
- Virax may not be held liable for any damage caused by improper use of the descaling pump and associated chemicals.
CAUTION
- Never pull the pump by the supply cable or hoses.
- Do not use the pump if the supply cable and hoses are faulty.
- When using an extension, the power plug and socket must be waterproof.
- Read carefully the Safety Data Sheet of the scale solvent, apply any safety measures specified, and wear the individual protection devices planned.
- Using a scale solvent incompatible with the materials in the unit may damage it.
Start-up
Connection the pump
- Cut the water supply and bleed the unit to be descaled.
- Check visually for damage on connections and hoses, and change them if required (see nomenclature)
- Connect the pump to be descaled directly to the boiler’s heating unit (or exchanger). Direct connection to the heating unit avoids damaging gaskets on the inlets and outlets of the boiler.
- Fill the pump’s water tank with a quantity of water sufficient to maintain the pump casing immersed during operation
CAUTION
Check that the level of liquid doesn’t exceed 5 cm under the tank cap; an
excessive level of liquid would damage the motor.
- Connect the power supply cable to a single-phase 230V power outlet.
- Switch on the pump by pressing the switch, and check the proper behavior of the connections
- Stop the pump.
Descaling operation
- Choose the appropriate Virax descaler and dilute it in water as indicated on the descaler bottle.
- Start the pump
- During operation, maintain the tank cap open to evacuate any gas forming during descaling.
CAUTION
The temperature of the descaling product must never exceed 50°C.
During descaling, check that the height of the foam forming inside the tank
does not exceed the maximum filling level.
-
Actuate the flow reverser several times to attack the cap in both directions.
-
If the water+descaler solution loses its initial color during the descaling operation, add the descaler immediately to the tank
-
The descaling operation is complete when:
-
the flow of the solution in the hoses at the inlet and outlet of the heating unit is identical and has no small bubbles at the outlet
AND -
the water+descaler solution keeps its initial color at the outlet
-
Stopping the operation
- Stop the motor and disconnect the pump
- Slightly loosen the connection at the pump outlet to let the air enter the circuit and the product flow into the pump tank.
CAUTION
During this operation, beware of any acids that may remain inside the circuit,
and which are likely to drip and damage the floor.
- When the liquid has bled from the hoses, disconnect the 2 hoses.
- To neutralize the descaling solution, pour the appropriate Virax neutralizer into the tank, and dilute according to the indications mentioned on the neutralizer bottle.
- Empty the tank.
Rinsing the unit
- In the descaler pump tank which is now empty, dilute the Virax neutralizer with water (according to the indications mentioned on the neutralizer bottle).
- Connect the hoses to the heating unit as previously
- Start the pump and run this solution for a few minutes.
- Prime the unit and rinse with clean water (20 to 30 liters of water) to eliminate any product residue.
CAUTION
The tank must be empty at all times and cleaned to prevent damage to the
motor.
Technical specifications
- Supply voltage 230V – 50Hz
- Protection rating: IP 54
- Maximum operating temperature: 50°C
- Power: 150 W
- Flow rate: 33 l./ min
- Elevation height: 12 m. (The pressure is measured at the pumping body outlet)
- Tank capacity: 15 litres
- Delivered with 2 hoses and connections
Guarantees
All our products have a 2-year guarantee.
Find the list of our dealers on www.virax.com
Tél : +33 (0)3 26 59 56 78
Fax : +33 (0)3 26 59 56 20
client.fr@virax.com
INTERNATIONAL Tel: +33 (0)3 26 59 56 97
Fax : +33 (0)3 26 59 56 70 export@virax.com
ACHATS/PURCHASING Tel: +33 (0)3 26 59 56 06
Fax : +33 (0)3 26 59 5610
purchase.dpt@virax.com