wiha 12-1.000 V Volt Detector Instruction Manual

June 14, 2024
wiha

wiha 12-1.000 V Volt Detector

wiha-12-1.000-V-Volt-Detector-PRODUCT

Specifications

  • Protection class: CAT IV 1000 V
  • Temperature range: Not specified
  • Relative humidity: Not specified
  • Dimensions (L x W x H): Not specified
  • Weight (without / with battery): 40 g / 50 g

Product Usage Instructions

Operational control

  • a. Testing tip
  • b. LED indicator
  • c. Ready-to-use indicator
  • d. Power on/off button
  • e. Flashlight on/off switch
  • f. End cap
  • g. Torch

Indication & automatic switch-off

Fitting/replacing the battery

  • Battery type: 2x 1.5 V AAA
  • Low battery: the ready-to-use indicator LED flashes

Preparing the device

Check the voltage tester is safe and intact on a regular basis (e.g. examine for damage to the housing or deformation).

Note: All LEDs light up briefly when device is switched on.

Checking the voltage
Visual and audible testing signal

Indicator (reference only)

Mute mode

FAQ

  1. What is the voltage range that this tester can detect?

The voltage tester can detect voltages in the range of 12 – 1000 V AC.

  1. What is the purpose of the flashlight feature?

The flashlight feature can be used to provide illumination in dark areas when using the voltage tester.

  1. How do I know when the battery needs to be replaced?

The ready-to-use indicator LED will flash to indicate a low battery.

Operating instructions

VoltDetector 12-1000 V
This contactless voltage tester is used to test alternating electric fields.
It can detect voltages in insulated cables, e.g. spot cable breaks.

Safety instructions

  • AC > 50 V
  • DC > 120 V

Above these voltage limits: life-threatening electric shock if touched.

  • The warranty is voided in the event of injury or damage to property caused due to non-compliance with these operating instructions. The manufacturer accepts no liability for consequential damage.
  • Operational safety is no longer guaranteed if the voltage tester has been modified in any way. Do not disassemble. Do not disassemble.
  • Test the device on a known voltage source before and after you use it.

Proper use

  • Voltage: 12 – 1000 V AC
  • Frequency: 40- 500 Hz
    • Only trained technical staff may use the voltage tester.
    • The voltage tester must not be used to verify that there is no live current.
    • You may only use a two-pole voltage tester as per EN61243-3 to verify that there is no live current.
    • You must pass on the operating instructions as well if you give voltage tester to a third party.

Operational control

  • a Testing tip
  • b LED indicator
  • c Ready-to-use indicator
  • d Power on/off button
  • e Flashlight on/off switch
  • f End cap
  • g Torch

Indication & automatic switch-off

Fitting/replacing the battery

  • Battery type: 2x 1.5 V AAA
  • Low battery: the ready-to-use indicator LED flashes

Preparing the device

Check the voltage tester is safe and intact on a regular basis (e.g. examine for damage to the housing or deformation).

Note: All LEDs light up briefly when device is switched on.

Checking the voltage

Visual and audible testing signal

Indicator (reference only)

Field force depends on:

  • connected voltage
  • Distance from power source

 Mute mode

wiha-12-1.000-V-Volt-Detector-7

Technical specifications

Protection class IP67
Temperature range -20 °C – +40 °C
Relative humidity < 80% rF
Dimensions (L x W x H) 150 x 28 x 28.5 mm
Safety tested as per EN 61010-1:2010

Weight
(without / with battery)| 40 g / 50 g

Cleaning

  • Switch off voltage tester before cleaning.
  • Clean voltage tester with a damp cloth – do not use any scouring or solvents.
  • Dry thoroughly before using again.

Disposal

  • Dispose of the voltage tester as per the applicable statutory regulations.
  • You must dispose of empty batteries properly and separately from the product.

Warning: dangerous voltage, risk of electric shock and impact on the voltage tester’s electric safety.

Important Observe the indications in the operating instructions.

Uninterrupted double or reinforce insulation as per Category II EN 61140.
Protection against electric shock.

Complies with European specifications.

Complies with European specifications.

Canadian Standards Association (NRTL/C)

Complies with applicable Australian regulations.

The voltage tester meets WEEE Directive (2012/19/EU).

CAT IV
1000 V
The voltage tester is used to measure the source in low-voltage installations (i.e. electrical measuring devices and measurements on counters, overcurrent protection devices and load management devices).