Meissalivve T-59C3 Single Person Spruce Far Infrared Sauna Owner’s Manual

June 1, 2024
Meissalivve

Meissalivve T-59C3 Single Person Spruce Far Infrared Sauna

Meissalivve-T-59C3-Single-Person-Spruce-Far-Infrared-Sauna-
PRODUCT

Device Structure

Composition

  • The product consists of a base, fore-body, rear-body, left-body, right-body and top plate. The left side of the product is equipped with a seat. A lower seat cover is provided under the seat front.
  • The room plates and seat are equipped with inner fasteners. The lower seat cover is embedded in the seat support.
  • A main power switch and LCD digital control panel are installed in the upper part of the room to control the operational status of the product. Also, a light is installed in the Room.

Description of Control Panel

  • A: Power button
  • B: Time adjustment key
  • C: Temperature adjustment key
  • D: Foot heating
  • E: Colored lamp button
  • F: Lighting lamp button
  • G: Volume control button
  • H: Music selection button
  • 1: Music and telephone button
  • J: Temperature display window
  • K: Time display window
  • L: Device status display window

Bluetooth app connection

  • Scan the QR code below with your mobile phone, pop up the connection, open and install.
  • Open bluetooth, open app, and click” Add Device”.
  • Enter the search interface and start searching for “Hehui-R
  • Click “Hehui-Room” and add the device, and the product v gives a prompt tone of “Drop”, indicating that the connection successful.
  • Return to the operation interface of the sauna room, and then you can perform relevant operations on the mobile phone.
  • When Bluetooth is turned off or beyond the Bluetooth connection range, the controller will sound a “Drop” tone, indicating that the connection is disconnected

Operating Instructions

Start/Stop

  1. 1. After turning on the power, press and hold the power button for
  2. seconds to turn on the controller. To turn off the controller, press and hold it for another 2 seconds.

Time Settings

  1. 1. To set a timer: Press “A”/” V” until the desired target time is set. Press either button once to display the previously set time and enter the setting mode. Press them again while in setting mode to increase/decrease the duration of the timer by 1 minute per press. The range of settings for the time is limited to 1-60 minutes, and when the device is first activated, the default timer is set to 60 minutes.
  2. After the time has been set, it will count down automatically. After the set time has been reached, it will stop heating automatically, o”o” will flicker on the timing time display window for 1 minute and then the control system will shut down

More convenient with downloading APP If the mobile phone of ISO system cannot be scanned, please search for “RIGO” in the app store.

  • While setting the time, press and hold “A”/” V” for more than 2 seconds to have the set time continuously increase/decrease by 1 minute per interval. After the time has been set, the number shown in the time display window will start to flicker. If no other operations are performed after it has flickered three times, the device will automatically exit from setting mode and begin to count down. After the countdown is complete, the spectrum energy room will be turned off.
  • The spectrum energy room has an automatic memory function, and after each time it is activated and in standby mode, will display the previous length of time set by the user while in standby mode.

Temperature Settings

  • Set the required temperature:
  • Press “A”/” V” until the desired target temperature is set. Press either button once to display the previously set temperature and enter the setting mode. Press them again while in setting mode to increase/decrease the temperature by 1C per press. The temperature range is limited to 20-60 C, and when the device is first activated, is set to 50 C by default.
  • While setting the temperature, press and hold “^”/”V” for more than 2 seconds to have the set temperature continuously increase/decrease by 1C per interval. After the temperature has been set, the number shown in the temperature display window will start to flicker. If no other operations are performed after it has flickered three times, the device will automatically exit from setting mode and display the current temperature. When the ambient temperature is lower than the set temperature, the spectrum energy room will start to heat up. When the ambient temperature reaches the set temperature, the spectrum energy room will stop heating, and the temperature display window will display the set temperature.
  • The spectrum energy room has an automatic memory function, and after each time it is activated- ed and in standby mode, will display the previous temperature set by the user.

Foot Heating

  • The foot heating plate will begin to heat up automatically after startup. Pressing the foot heating button will turn off the foot heating plate; pressing it again will cause the foot heating plate to start to heat up again.

Colored Lamp

  • The coloured lamp is activated by default after startup, and the colour changes automatically and cyclically. While the lamp cycles through its various colours, press the coloured lamp button to fix the coloured lamp to the currently emitted color. Press it again to resume automatic colour cycling. This process may be repeated.
  • Press and hold the coloured lamp button for 2 seconds to turn the coloured lamp is off. You may then press the button to turn the coloured lamp on again.

Lighting Lamp

  • The lighting lamp is activated by default after startup. Press the lighting lamp button to turn off the lighting lamp; press it again to turn the lighting lamp back on.

Volume Control

  • While playing music, press “ “/”V” to set the required volume. The volume range is limited to 1-10. Press the volume control button to increase/decrease the audio volume by 1 per press, or press and hold it for more than 2 seconds to make the volume progressively increase/decrease by 1 unit per interval. When the power is first switched on, the volume is 5 by default.

Music Selection

  • While playing music, press “ “/” V” to switch to the previous track or the next track.

Playing Music

  • While playing music, press the music button to stop playing music, and press it again to play music.

Handling Telephone Calls

  • After device startup, when receiving a call by Bluetooth, press the phone icon to answer the phone. Press it again to hang up. Press and hold the button for 2 seconds to reject a call.

Bluetooth Music Connection

  • Turn on Bluetooth, search for the Bluetooth device HEHUI-ROOM, and select it to connect the device.
  • The mobile phone will display a Bluetooth pairing code for the Bluetooth device. Enter pairing code 0000 to connect to the device.
  • After the device has been connected successfully, turn on the music player to play music. When receiving a call, you may use the device to answer/end/reject a call.

Alarm Function

  • When the device is active and four or more buttons are pressed down at the same time, the alarm function is enabled. Perform this action again to disable the alarm function.

Installation

Installation Instructions

  • The plate is quite heavy. Please be careful to avoid accidental injuries in the process of installation.
  • The product should be assembled by two adults.

Installation Steps

  • There is a “+” fastener and a “-” fastener on the side of each plate. A “+” fastener is connected to a “-” fastener during installation. The installation method is as follows: Lift the plate with “+” fasteners 10 cm above the plate with “-” fasten- ers (Figure 1); move the plate with “+” fasteners close to the plate with “-” fasteners (Figure 2); and then move it down until the plate with “+” fasteners is aligned with the plate with “-” fasteners (Figure 3). If the height is not equal or there is an obvious gap between the two plates, it indicates that the assembly is wrong and it should be re-assembled.

Meissalivve-T-59C3-Single-Person-Spruce-Far-Infrared-Sauna-
FIG-2

  1. Suggest three or more persons to complete the installation. Place the bottom of the sauna on the level floor.
  2. Place the back of the sauna in the bottom slot and need a person to hold it.
  3. Install the left piece of the sauna room, place the left piece on the buckle of the back piece, and buckle it.
  4. Install the right piece of sauna room, place the right piece on the buckle of the back piece, and buckle it.
  5. Install the front piece of the sauna room, place the front piece on the buckle of the right and left piece, and buckle it.Meissalivve-T-59C3-Single-Person-Spruce-Far-Infrared-Sauna-FIG-5
  6. Before installing the handle, remove the screw from the handles first. Pay attention to the circular cylinder.
  7. Install the handle, lock the handle on the glass door with screws, and put the circlular cylinder into the glass hole.
  8. Install the bench support, and insert the slots into the fixed strips of the left and right baffles. Connect the wirings well.
  9. Install the bench, connect the bench light cable to the inner bottom, and insert the bench into the rear slot. Put the light cable into the hole reserved for the baffle to prevent it from being crushed by the bench.
  10. Put the bench in the right position.Meissalivve-T-59C3-Single-Person-Spruce-Far-Infrared-Sauna-FIG-3
  11. Install the ceiling of the sauna, stick the top slot into the slot of four panels, and pay attention to the connection line that should pass through the top-line slot. Put the ceiling panel on.
  12. Take out the power plug from the top of the back panel, and connect all the wirings in the ceiling.
  13. Plug in, and ensure that the power supply voltage ranges from 110V to 130. When the sauna room is powered on for the first time, the lights inside will be on directly and need to be turned off on the control panel if necessary.
  14. Put the wirings into slots and lock them with screws.
  15. Lock screws in surroundings with screw holes and the assembling is completed. ATTENTION: It is strictly prohibited to use a water gun for direct cleaning, and it is strictly prohibited to use this product on rainy days.Meissalivve-T-59C3-Single-Person-Spruce-Far-Infrared-Sauna-FIG-4
  16. Cup holder installation. The customer decides whether to install it at their own discretion.
  17. Use NO.2 screw to install the cup holder onto the left plate, align the screw with the screw hole and tighten it.
  18. All installations are now complete. Customers need to pay attention to the waterproof treatment of power cord sockets. Unplug the power and wipe it with a damp cloth when cleaning it. Do not use a water pipe to rinse. It is strictly prohibited to soak in water inside. It is strictly prohibited to use on rainy and thunderstorm days. Please disconnect the power every time after use. Indoor use may not require the installation of triangular brackets and external roofs.

Installation Notes

  • Tightly fasten all room plate fasteners during installation and be sure the plug under the seat plate is installed correctly.
  • The product must be placed away from heat sources and moisture, and at least 20 cm away from walls or other objects.
  • A three-hole socket with a reliable grounding terminal must be used to plug in the device.
  • The power supply voltage used must be consistent with the voltage value indicated on the product nameplate.
  • Don’t let the power cord be crushed under the room base or other heavy objects, and do not forcibly pull or squeeze the power cord.

Application Method of Product

Instructions

  • Preheating
  • Close the air hole on the top of the product.
  • Start the operation by pushing the power button on the control panel.
  • Press the TEMP adjustment button to set the temperature, temperature can be set up to 40-50 °C.
  • Press the time adjustment button to set the required time (about 20-30 min) and enter the preheating state. After about 20 min, the room reaches the set temperature and keeps constant automatically.
  • Please don’t open the product door frequently.
  • After the temperature is constant, change the set temperature and open the product door temporarily to accelerate cooling while reducing the internal temperature of the product.
  • Timing After preheating to the set temperature, adjust the timing switch to adjust to the preset time; Close the product door after entering.
  • Finish using Press the power switch to turn off the power supply

Precautions During Use

  • When using the product, please check whether the power supply meets the requirement (whether there is a grounding device).
  • Please don’t take clothes, shoes, metal jewellery, watches and other items into the product.
  • Don’t put combustibles such as a lighter, liquified gas, gasoline and alcohol and corrosive products such as strong acids and alkaline in the product.
  • Please don’t stretch your fingers into the heating plate’s protective cover in the hot product.
  • Don’t smoke in the product or bring any fire.
  • The product may not be made so hot during use in wintertime or cold weather or low indoor temperatures (lower than 10 C). To ensure the internal temperature of the product, please keep the indoor temperature at about 20C.
  • In principle, don’t use the product immediately after a meal, but actually one hour after the meal.
  • In principle, don’t take a shower immediately after using the product, but two hours after using.
  • When using the product, please drink more warm water to supplement the water lost during perspiration.
  • Stop using if it is uncomfortable when using the product.
  • Please wipe your sweat after using, and keep warm to avoid catching a cold.
  • Don’t remove the parts such as a control panel and heating plate arbitrarily.
  • lt is suggested that the nerdiest shall not he listed continitolisly for more than 9 hours.

Power Safety

  • The power supply and power circuit must be provided with reliable grounding during use; the power cord is equipped with a reliable grounding wire to avoid excessive use of product producing a large amount of water vapor and causing electrostatic induction, voltage increase, short circuit, smoking, tripping and other phenomena.
  • Please don’t use the power supply beyond the national standard voltage (e.g. 220V for China, 240V for Malaysia and 120V for America) to avoid fire and electric shock.
  • Do not work on, curl, or damage the power cord to avoid sparking and electric shock.
  • Make sure that there is no water or debris in the plug or in the gap to avoid electric shock or other malfunctions.
  • When plugging in or unplugging the power cord, please hold the head of the plug and ensure your hands are dry to avoid the risk of electric shock.
  • Families with pets should pay attention to prevent the pets from biting the power cord or urinating on the plug, which may cause fire or other accidents. When going out, be sure to unplug the device and place the product in a place beyond reach of pets.
  • Replacement of the power cord other than by professionals is strictly prohibited. Please contact professional maintenance service or electricians for replacement or maintenance.

Unsuitable Users
The following groups are strictly prohibited from using the product

  • Patients with diabetic foot, severe cardiovascular and cerebrovascular disease.
  • Patients with cancer in the process of radiotherapy and chemotherapy.
  • Infants and young children, pregnant women, and menstruating women.
  • Patients with glaucoma, cataract and bleeding tendencies.
  • Patients with active tuberculosis, severe arteriosclerosis, malignant tumor, and blood coagu- lation disorders.
  • Patients wearing pacemakers,or with steel plates or other metal inside the body.
  • Patients with burns and fractures.
  • People with electromagnetic sensitivity.
  • People with a history of cerebral infarction or myocardial infarction.
  • People with the lower than normal blood platelets.
  • People requiring frequent infusions within 2-5 years owing to cardiovascular and cerebro- vascular diseases or easily damaged blood vessels.
  • People drinking a lot of alcohol or taking sleeping pills within the last 24 hours.
  • Patients with mental disorders, patients who can not take care of themselves, have no self-awareness. and have no independent behavioral abilitv.

If you are not physically healthy, please use this device under the guidance of a professional!

Product Cleaning and Maintenance

Cleaning Method of Product

  • Open the product door and remove the dust, hair and small sundries in the room with a duster or soft hair brush; wipe the whole room, seat and frame feet with a dry towel that has strong water absorption, discharge the moisture in the room and disinfect and sterilize.
  • Enable the machine to run idle at least once a week (30 min each time), so as to keep the dryness of the inner room and reduce the electrostatic induction.
  • If the room is frequently used, dehumidify it as stated above after each use. A thorough cleaning is also required after each day of use.
  • If the room is not used or you plan to be away for long periods, ensure that the power is unplugged to avoid potential safety risks.
  • Please clean after the product is powered off.
  • Please maintain the product when the temperature of the inner room is reduced to the indoor temperature.

Precautions for Product Maintenance

  • Overall movement
  • Pull out the power plug and arrange the power line.
  • Close and fix the room door.
  • When moving the product, please lift the base of the room body rather than push the vertical plate of the room forcibly.
  • Handle with care during movement to avoid room damage.
  • Equipment cleaning
  • When wiping the room wall and protective cover, please avoid touching the frequency spectrum plate.
  • Don’t wipe the product with a chemical cleaner.
  • Don’t wash and sprinkle the interior and exterior of the product or wipe the control panel and knob with alcohol or other solvent.
  • Don’t dismount, repair and transform the product on its own; if it is necessary to change the controller, please operate when the product is powered off.
  • Don’t use the product as storage space.

Specifications

Technical Data
This product is designed and manufactured according to the safety requirements of relevant standards.

  • Technical Data
  • Type: T-59C3

Working Conditions

  • Ambient temperature: -5°C ~ +40°C

  • Relative humidity: ≤75%

  • Rated power: 50-60Hz

  • AC100V

  • AC110V

  • AC120V

  • AC220V

  • AC230V

  • AC240V

Note

  • Improvements and changes to the data may be made without further notice.
  • Damaged parts or expired components should be disposed of according to the regulations for disposal of general electrical waste.
  • In case of any problems, please contact the local dealer or manufacturer.

After-sales Service Guide

Free warranty period of product
12 months or accumulated use of 2000 hours The free warranty period starts from the date of receipt. Users can enjoy 12 months of free warran- ty and life-long paid maintenance (during the free warranty period, if the accumulated use time reaches 2000 hours, then the accumulated use time shall prevail).

The following conditions are excluded from the scope of the warranty

  • Failure caused by force majeure factors (such as war, earthquake, flooding, mudslide, typhoon, lightning, etc.), improper use/maintenance, abnormal operation and modification, or other accidents.
  • Failure to provide the warranty card and proof of purchase, and product damage caused by disassembly without consent of our technical service personnel.
  • After the warranty period expires, the Company will provide lifetime paid maintenance and will only charge the maintenance costs.

Maintenance Method

  • Warranty service: Within the free warranty period, in case of a malfunction caused by the product itself, customers should bring the product to the Company or have it couriered, attac – hing a detailed description of the malfunction along with the customer’s telephone number and shipping address, so as to facilitate the Company to repair and returning the product to the customer as soon as possible.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals