LEDOLUX HERMES ECO Oprawa liniowa LED Instruction Manual
- June 1, 2024
- LEDOLUX
Table of Contents
HERMES ECO 2
HERMES ECO Oprawa liniowa LED
| L| W| H| Wag a
---|---|---|---|---
20W| 605mm| 83mm| 75mm| 0.75kg
40W| 1205mm| 83mm| 75mm| 1.50kg
60W| 1505mm| 83mm| 75mm| 1.50kg
Instruction manual
NOMINAL VOLTAGE………………. 200 – 240V ~
FREQUENCY……………………… 50 / 60Hz
COLOUR TEMPERATURE……………… 4000K
LUMINOUS EFFICACY…………………… 140lm/W
BEAM ANGLE……………………………. 135°
OPERATING TEMPERATURE……….. -20°C ÷ +40°C
MOUNTING HEIGHT……………………. 2 – 6m
The outer diameter of the electric wire
Suspended mounting
-
Fix the screws on the ceiling.
Attach the mounting cables. -
Adjust the length of the cables.
Lock the length by turning the clamping handle.
Attach the mounting bracket to the cables. -
Fix the luminaire to the mounting bracket.
Connect the luminaire to the power supply according wire marking below.
Ceiling mounting
- Drill holes with a 6mm diameter drill, attach themounting brackets to the ceiling.
- Mount the luminaire in the mounting bracket.
- Connect the luminaire to the power supply according wire marking below.
Connecting the cables
**NOTE**
Connecting the PE cable brings the luminaire to protection class I
NOTE
Terminal block is not supplied.
Installation must be performed by a qualified person. In case of doubts as to
the installation or use of the LED luminaire, consult manufacturer Replace the
luminaire after a failure. Selfrepair shall void the warranty.
This product contains a light source with energy efficiency class C.
Do not install the luminaire in an environment with high chemical exposure
(e.g. chemical factories, animal pens).
Keep the luminaire in a cool, dry and clean environment. Keep away from water
and fire.
Make sure you disconnect the power supply before installation. Turn on the
power after connecting and securing all luminaires in the circuit.
The light source used in this luminaire should only be replaced by the
manufacturer or their service representative, or a similarly qualified person.
Protect your eyes, avoid looking at the light for a long period of time.
Dirtiness that settle down on the luminaire due to normal operation shall be
cleaned with a damp cloth. Do not use invasive cleaners or cleaning methods.
APPLICATION
- Industrial facilities
- Warehouses
- Sport facilities
- Commercial facilities
Ledolux Poland Sp. z o.o.
Ul. Innowacyjna 1
36-060 Głogów Małopolski
POLSKA
E-mail:info@ledolux.pl
Tel: +48 696 966 622
Data: 29.11.2023
We reserve the right to make design changes to luminaires.
Documents / Resources
|
LEDOLUX HERMES ECO Oprawa liniowa
LED
[pdf] Instruction Manual
HERMES ECO Oprawa liniowa LED, HERMES ECO, Oprawa liniowa LED, liniowa LED,
LED
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>