Dimension

Dimension

P /Pin [W] Wymiary LxWxH [mm] Waga [kg]
1 – 30 510x510x550 8.5
31 – 40 510x510x550 8.5
41 – 60 510x510x550 8.5
61 – 80 510x510x550 8.5

NOMINAL VOLTAGE
205 – 250V ~

FREQUENCY
50 / 60Hz

COLOUR TEMPERATURE
2700K / 4000K

LUMINOUS EFFICACY
150lm/W

BEAM ANGLE
Symetrical / Asymmerical

OPERATING TEMPERATURE
-40°C ÷ +40°C

MOUNTING HEIGH
2 – 8m

WARNING!!

When installing luminaires on composite poles, it is absolutely necessary to ground the fixture. In case of any problems in this matter, please consult the manufacturer.

Tool

Hex key 4mm

Tool

Mounting diameter:

ø50-75mm.

Installation

  1. Make sure you disconnect the power supply before installation.

  2. Mount the luminaire on the pole. Mounting diameter ø50-75mm.
    Connect the luminaire wire to the power cord as indicated below.
    Use a connector with an appropriate degree of protection IP.

NEMA socket

NEMA socket

Attach the controller to the NEMA socket by pressing and turning as indicated on the controller.
If there is no controller, secure the NEMA socket by installing a special Jumper.

The outer diameter of the electric wire

min max
Ø9 – 10mm

Connecting the power cable

L Brown
N  Blue

NOT INCLUDED

Not Included

NOTE

Terminal block is not supplied. Installation must be performed by a qualified person.
In case of doubts as to the installation or use of the LED luminaire, consult manufacturer.

Replace the luminaire after a failure. Self-repair shall void the warranty.

This product contains a light source with energy efficiency class:
A for CCT=4000K
B for CCT=2700K.

Keep the luminaire in a cool, dry and clean environment. Keep away from water and fire.

Make sure you disconnect the power supply before installation. Turn on the power after connecting and securing all luminaires in the circuit.

The light source used in this luminaire should only be replaced by the manufacturer or their service representative, or a similarly qualified person.

Protect your eyes, avoid looking at the light for a long period of time.

Dirtiness that settle down on the luminaire due to normal operation shall be cleaned with a damp cloth. Do not use invasive cleaners or cleaning methods.

APPLICATION

  • Street lighting
  • Park lighting,
  • Car parks lighting
  • Exterior lightning

Symbols

CUSTOMER SERVICE

Ledolux Poland Sp. z o.o.
Ul. Innowacyjna 1
36-060 Głogów Małopolski
POLSKA

E-mail: info@ledolux.pl
Tel: +48 696 966 622
Data: 02.03.2023
We reserve the right to make design changes to luminaires.

LEDOLUX Logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals