Features

  • MEANWELL Patent Number :ZL202220241473.0
  • AC input range selectable by switch
  • Withstand 300VAC surge input for 5 second
  • Protections: Short circuit / Overload / Over voltage /Over temperature
  • Forced air cooling
  • Built-in cooling Fan ON-OFF control
  • 1U low profile
  • Withstand 5G vibration test
  • High operating temperature up to 65°C
  • Operating altitude up to 5000 meters (Note.10)
  • 3 years warranty
  • MTBF>1KK hrs

Applications

  • Industrial automation machinery
  • Industrial control system
  • Mechanical and electrical equipment
  • Electronic instruments, equipments or apparatus

GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx

Description

LRS-600 series is a 600W single-output enclosed type power supply with 41mm of low profile design. Adopting the input of 115VAC or 230VAC (select by switch), the entire series provides an output voltage line of 5V, 12V, 15V, 24V, 27V, 36V and 48V.In addition to the high efficiency up to 92%, with the built-in long life fan LRS-600 can work under -20~+65°C with full load. LRS-600 has the complete protection functionsand 5G anti-vibration capability; Itis complied with complete international safety regulations. LRS-600 series serves as a high price-to-performance power supply solution for various industrial applications.

Model Encoding

MEAN WELL LRS 600 12 Single Output Switching Power Supply-
mode

SPECIFICATION

MODEL| LRS-600-5| LRS-600.12| LRS-600-15| LRS-600-24| LRS-600-27| LRS-600-36| LRS-600-48
---|---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 5V| 12V| 15V| 24V| 27V| 36V| 48V
RATED CURRENT| 100A| 50A| 40A| 25A| 22.2A| 16.6A| 12.5A
CURRENT RANGE| 0 – 100A| 0 – 50A| 0 – 40A| 0 – 25A| 0 – 22.2A| 0 – 16.6A| 0 – 12.5A
RATED POWER| 500W| 600W| 600W| 600W| 599.4W| 597.6W| 600W
RIPPLE &NOISE (max.) Note.2| 200mVp-p| 200mVp-p| 200mVp•p| 240mVp-p| 270mVp•p| 360mVp-p| 360mVp-p
VOLTAGE ADJ. RANGE Note.3| 4.75 – 5.5V| 11.4 -13.2V| 14.25 -16.5V| 22.8 – 26.4V| 25.65 – 29.7V| 34.2 – 39.6V| 45.6 – 52.8V
VOLTAGE TOLERANCE Note.4| –1–2.0%| ±1.5%| ±1.0%| 11.0%| ±1.0%| ±1.0%| 11.0%
LINE REGULATION Note.5| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION Note.8| 12.0%| ±1.0%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME Note.7| 1300ms. 50ms/230VAC          1300ms,50ms/115VAC at full load
HOLD UP TIME (Typ.)| 20ms/230VAC    l6ms/115VAC at full load
INPUT| VOLTAGE RANGE      Note.8| 90 – 132VAC / 180 – 264VAC by switch 255 – 370VDC (swith on 230VAC)
FREQUENCY RANGE| 47 – 63Hz
EFFICIENCY (Typ.)| 86%   190%| | 190%| 191%| 191%| 192%

192%

AC CURRENT (Typ.)| 12A/115VAC         7.5A/230VAC
INRUSH CURRENT (Typ.)| 35A/115VAC         60Al230VAC
LEAKAGE CURRENT| <2mA/ 240VAC
PROTECTION (Note.9)| OVER LOAD| 105 – 150% rated output power
Constant current limiting. unit will shutdown after 3 sec. re•power on to recover
OVER VOLTAGE| 525 – 6.75V   113.8| – 16.2V     118| -21V     127.6| – 32.4V 131| – 36.5V   141.4| – 48.6V   155.2| – 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, re-power on to recover
FUNCTION| FAN ON/OFF CONTROL ITVP.)| RTH3      51:1″C FAN ON. 540t FAN OFF
ENVIRONMENT| WORKING TEMP.| -20 – +65C (Refer to –Derating Curve’)
WORKING HUMIDITY| 20 – 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 – +85 C . 10 – 95% RH
TEMP. COEFFICIENT| ±0.03%/12 (0 – 50C)
VIBRATION| 10 – 500Hz, 5G 10min./1cycle. 60min. each along X, Y. Z axes
OVER VOLTAGE CATEGORY| III: According to EN61558. EN50178, EN60664-1, EN62477-1; altitude up to 2000 meters
SAFETY| SAFETY STANDARDS| BS IEC/UL 62368-1. EAC TP TC 004. KC62368-1(except for 5V), BIS I513252(Part1):2010/1EC60950-1: 2005(except for 48V).BSM I CNS15598-1.GB 4943.1,BS EN/EN61558-1.BS EN/EN61558-2-16 approved. Designed by AS/NZS 61558.1/2.16, AS/NZS 62368.1
WITHSTAND VOLTAGE| UP-0/P:3.75KVAC      I/P-FG:2KVAC      0/P•FG:0.5KVAC
ISOLATION RESISTANCE| 1/P-0/P. UP-FG, OJP-FG:100M Ohms/500VDC / 25’C/ 70% RH
EMC EMISSION| Compliance to EAC TP TC 020, BSMI CNS15936.KC KSC 9832, KSC 9835
EMC IMMUNITY| Compliance to EAC TP TC 020,KC KSC 9832, KSC 9835
OTHERS| MTBF| 1533.4K hrs min. Telcordia SR-332(Bellcore);        301.7K hrs min.       MIL-HDBK-217F (25t)
DIMENSION| 225.124’41mm (12W1H)
PACKING| 0.95Kg/12pcs/12.4Kg/0.77CUFT

NOTE

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.

  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

  3. Voltage adjustment can only be operated within the input range of 100~120VAC or 200-240VAC.
    If the voliage adjustment is performed outside this range, it may cause abnormal output.

  4. Tolerance : includes set up tolerance, iine regulation and load regulation.

  5. Line regulation is measured from low line to high line at rated load.

  6.  Load regulation is measured from 0% to 100% rated load.

  7. Length of set up time is measured at cold start. Turning the power supply onioff frequently may lead to increase of the set up time.

  8.  Derating may be needed under low input voltages. Please refer to”Static Characteristics” sections for details.

  9. Once protections are triggered, 4min(Typ.) of cold down time is required before restart

  10.  The ambient temperature derating of 5C/1000m is needed for operating alttude greater than 2000m(6500f).

  11. This power supply does not meet the harmonic current requirements outined by EN61000-3-2. Please do not use this power supply
    under the following conditons:
    a) the end-devices is used within the European Union, and
    b) the end-devices is connected to pubic mains supply with 220Vac or greater rated nominal voltage, and
    c) the power supply is:
    – installed in end-evices with average or continuous input power greater than 75W, or
    – belong to part of a lighting system
    Exception:
    Power supplies used within the following end-devices do not need to fulfil EN61000-3-2
    a) professional equipment with a total rated input power greater than 1000W;
    b) symmetically controlled heating elements with a rated power less than or equal to 200W 12RCM is on voluntary basis and meets relevant IEC or AS/NZS standards complying with ASNZS 4417.1. % Product Liability Disclaimer : For detailed information, please refer to https://fwww.meanwell.comiserviceDisclaimer.aspx

 Block Diagram

MEAN WELL LRS 600 12 Single Output Switching Power Supply- Block
Diagram Derating Curve

MEAN WELL LRS 600 12 Single Output Switching Power Supply- Derating
Curve

Static Characteristics

MEAN WELL LRS 600 12 Single Output Switching Power Supply- Static
Characteristics

Note: Due to the test method difference, the rating on label differ from derating curve as folow.
For 5V model, the output current states 100A on label when input voltage > 110Vac, and states 90A when input voltage < 110Vac, please refer o abel for detail

Mechanical Specification

CaseNo.292 Unit:mm

MEAN WELL LRS 600 12 Single Output Switching Power Supply- Mechanical
Specification

Terminal Pin No. Assignment

Pin No. Assignment Pin No. Assignment
1 AC/L 4-6 DC OUTPUT -V
2 AC/N 7-9 DC OUTPUT +V
3 FG