Forclover MC610 24 Inch x 30 Inch Surface Recessed Mount Silver Mirrored
Soft Close Medicine Cabinet
List of Parts
Tools Needed
Rough Wall Opening
Overall Size | Rough Wall Opening |
---|
24 in.(WJ X 30 in(HJ X 5 in.(DJ
|
23-1 /4 in(WJ X 29-1 /4 in. (HJ X 3-7/8 in. (DJ
Use a 1/4 in. (6 mm) drill bit for drywall anchor installation. Use a 1/8 in. (3mm)drill bit for direct stud installation.
NOTE: If installing into a material otherthan drywall or into stud, consult aprofessional for proper installation.
ASSEMBLY
Step 1
Measure and mark two bottom mounting holes on the wall corresponding to the
pre-drilled hole locations in the bottom mounting bar.
Use a 1/4 in. (6 mm) drill bit for drywall anchor installation. Use a 1 /8 in. (3mm) drill bit for direct stud installation.
NOTE: If installing into a material other than drywall or into stud, consult a professional for proper installation.
Step 2
Attach the bottom mounting bar hanger to the wall with two mountin screws from the hardware pack.
Step 3
Install the top bar hanger with the same way as the bottom bar hanger.
follow the mounting instruction
Put the cabinet on the bottom bar hanger and hold the cabinet, please make sure that the hanger must mach the track from the bottom board of the cabinet
RECESS MOUNT INSTRUCTIONS
NOTE: Rough opening is not an exact measurement. The extra space allows cabinet to be inserted into the opening. Add shims to level and tighten space if necessary. Additional framing might be required.
STEP 1
NOTE: Before cutting the rough opening,check for pipes, electrical cables, or heatingducts. If it is required to remove part of stud, make sure that the wall is not a load bearing wall.
Prepare the opening in the wall for the cabinet body. Make sure that there is support on both sides of the opening to attach the cabinet body , as shown.
NOTE: The cabinet height should be a minimum 2 in. above faucet.
STEP 2
Position the cabinet body in the rough wall opening. Make sure that the
cabinet body flange covers the wall opening uniformly.
Secure both sides of the cabinet body to the wall supports using mounting
screws .
NOTE: The cabinet body must be level for the door to work properly.
SHELF ADJUSTMENT
For your convenience, adjustable shelves have been pre-installed. In order to adjust shelf location:
- Carefully slide the shelf out from shelf clips. See fig.1.
- Loosen each shelf clip screw (two for each shelf) and slide to the desired location.See fig 2.
- Carefully slide the shelf into the shelf clips making sure shelf is level and retighten shelf clip screws.
HINGE ADJUSTMENT
SIDE-TO-SIDE:
Door is adjustable side to side by turning screw A clockwise or
counterclockwise.
UP-DOWN:
Loosen screw Bon both top and bottom of hinge plate. Raise or lower door to
the desired position and re-tighten both screws.
IN-OUT:
Loosen screws Con both top and bottom hinges. Move the door in or out to
desired position and re-tighten.